Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě

Lucie Vaňková, Lucie Maixnerová, Karel Čížek, Jan Fischer, Jiří Barek, Tomáš Navrátil, Bogdan Yosypchuk

Результат исследований: Материалы для журналаСтатья

37 Цитирования (Scopus)

Выдержка

Optimum conditions are described for the determination of genotoxic 3-nitrofluoranthene (3-NF) and pendimethalin using differential pulse voltammetry (DPV). The limits of quantification (LQ) around 4·10-7 mol 1-1 were found for both 3-NF and pendimethalin. In addition, adsorptive stripping voltammetry was applied for determination of 3-NF with LQ around 3·10-8 mol 1-1. The practical applicability of newly developed methods was demonstrated on direct determination of pendimethalin in model samples of drinking water by DPV with LQ around 5·10-7 mol 1-1.

Язык оригиналаCzech
Страницы (с-по)1105-1110
Число страниц6
ЖурналChemicke Listy
Том100
Номер выпуска12
СостояниеОпубликовано - 1 дек 2006
Опубликовано для внешнего пользованияДа

Отпечаток

Mercury amalgams
Voltammetry
Silver
Electrodes
Drinking Water
pendimethalin
3-nitrofluoranthene

ASJC Scopus subject areas

  • Chemistry(all)

Цитировать

Vaňková, L., Maixnerová, L., Čížek, K., Fischer, J., Barek, J., Navrátil, T., & Yosypchuk, B. (2006). Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě. Chemicke Listy, 100(12), 1105-1110.

Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě. / Vaňková, Lucie; Maixnerová, Lucie; Čížek, Karel; Fischer, Jan; Barek, Jiří; Navrátil, Tomáš; Yosypchuk, Bogdan.

В: Chemicke Listy, Том 100, № 12, 01.12.2006, стр. 1105-1110.

Результат исследований: Материалы для журналаСтатья

Vaňková, L, Maixnerová, L, Čížek, K, Fischer, J, Barek, J, Navrátil, T & Yosypchuk, B 2006, 'Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě', Chemicke Listy, том. 100, № 12, стр. 1105-1110.
Vaňková L, Maixnerová L, Čížek K, Fischer J, Barek J, Navrátil T и соавт. Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě. Chemicke Listy. 2006 Дек. 1;100(12):1105-1110.
Vaňková, Lucie ; Maixnerová, Lucie ; Čížek, Karel ; Fischer, Jan ; Barek, Jiří ; Navrátil, Tomáš ; Yosypchuk, Bogdan. / Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě. В: Chemicke Listy. 2006 ; Том 100, № 12. стр. 1105-1110.
@article{14f091739fc6410aa9f2efc181404437,
title = "Voltametrick{\'e} stanoven{\'i} submikromol{\'a}rn{\'i}ch koncentrac{\'i} 3-nitrofluoranthenu a pendimethalinu NA stř{\'i} brn{\'e} pevn{\'e} amalg{\'a}mov{\'e} elektrodě",
abstract = "Optimum conditions are described for the determination of genotoxic 3-nitrofluoranthene (3-NF) and pendimethalin using differential pulse voltammetry (DPV). The limits of quantification (LQ) around 4·10-7 mol 1-1 were found for both 3-NF and pendimethalin. In addition, adsorptive stripping voltammetry was applied for determination of 3-NF with LQ around 3·10-8 mol 1-1. The practical applicability of newly developed methods was demonstrated on direct determination of pendimethalin in model samples of drinking water by DPV with LQ around 5·10-7 mol 1-1.",
author = "Lucie Vaňkov{\'a} and Lucie Maixnerov{\'a} and Karel Č{\'i}žek and Jan Fischer and Jiř{\'i} Barek and Tom{\'a}š Navr{\'a}til and Bogdan Yosypchuk",
year = "2006",
month = "12",
day = "1",
language = "Czech",
volume = "100",
pages = "1105--1110",
journal = "Chemicke Listy",
issn = "0009-2770",
publisher = "Czech Society of Chemical Engineering",
number = "12",

}

TY - JOUR

T1 - Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě

AU - Vaňková, Lucie

AU - Maixnerová, Lucie

AU - Čížek, Karel

AU - Fischer, Jan

AU - Barek, Jiří

AU - Navrátil, Tomáš

AU - Yosypchuk, Bogdan

PY - 2006/12/1

Y1 - 2006/12/1

N2 - Optimum conditions are described for the determination of genotoxic 3-nitrofluoranthene (3-NF) and pendimethalin using differential pulse voltammetry (DPV). The limits of quantification (LQ) around 4·10-7 mol 1-1 were found for both 3-NF and pendimethalin. In addition, adsorptive stripping voltammetry was applied for determination of 3-NF with LQ around 3·10-8 mol 1-1. The practical applicability of newly developed methods was demonstrated on direct determination of pendimethalin in model samples of drinking water by DPV with LQ around 5·10-7 mol 1-1.

AB - Optimum conditions are described for the determination of genotoxic 3-nitrofluoranthene (3-NF) and pendimethalin using differential pulse voltammetry (DPV). The limits of quantification (LQ) around 4·10-7 mol 1-1 were found for both 3-NF and pendimethalin. In addition, adsorptive stripping voltammetry was applied for determination of 3-NF with LQ around 3·10-8 mol 1-1. The practical applicability of newly developed methods was demonstrated on direct determination of pendimethalin in model samples of drinking water by DPV with LQ around 5·10-7 mol 1-1.

UR - http://www.scopus.com/inward/record.url?scp=33845785947&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33845785947&partnerID=8YFLogxK

M3 - Статья

AN - SCOPUS:33845785947

VL - 100

SP - 1105

EP - 1110

JO - Chemicke Listy

JF - Chemicke Listy

SN - 0009-2770

IS - 12

ER -