Voltametrické stanovení genotoxických dinitronaftalenů pomocí rtuťovým meniskem modifikované stříbrné pevné amalgámové elektrody

Aleš Daňhel, Karolina Pecková, Karel Čížek, Jiří Barek, Jiří Zima, Bogdan Yosypchuk, Tomáš Navrátil

Результат исследований: Материалы для журналаСтатья

44 Цитирования (Scopus)

Выдержка

Optimum conditions are described for the determination of genotoxic 1,3-, 1,5- and 1,8-dinitronaphthalenes (DNN) by differential pulse voltammetry (DPV) on the silver solid amalgam electrode modified with a meniscus. The limits of quantification were found to be 2·10-6 mol l-1 for 1,3-DNN, 1·10-6 mol l-1 for 1,5-DNN and 5·10-7 mol l-1 for 1,8-DNN. The DNNs in submicromolar concentrations cannot be determined by adsorptive stripping voltammetry on the above electrode.

Язык оригиналаSlovak
Страницы (с-по)144-149
Число страниц6
ЖурналChemicke Listy
Том101
Номер выпуска2
СостояниеОпубликовано - 1 фев 2007
Опубликовано для внешнего пользованияДа

Отпечаток

Mercury amalgams
Silver
Electrodes
Voltammetry
1,8-dinitronaphthalene

ASJC Scopus subject areas

  • Chemistry(all)

Цитировать

Voltametrické stanovení genotoxických dinitronaftalenů pomocí rtuťovým meniskem modifikované stříbrné pevné amalgámové elektrody. / Daňhel, Aleš; Pecková, Karolina; Čížek, Karel; Barek, Jiří; Zima, Jiří; Yosypchuk, Bogdan; Navrátil, Tomáš.

В: Chemicke Listy, Том 101, № 2, 01.02.2007, стр. 144-149.

Результат исследований: Материалы для журналаСтатья

Daňhel, A, Pecková, K, Čížek, K, Barek, J, Zima, J, Yosypchuk, B & Navrátil, T 2007, 'Voltametrické stanovení genotoxických dinitronaftalenů pomocí rtuťovým meniskem modifikované stříbrné pevné amalgámové elektrody', Chemicke Listy, том. 101, № 2, стр. 144-149.
Daňhel, Aleš ; Pecková, Karolina ; Čížek, Karel ; Barek, Jiří ; Zima, Jiří ; Yosypchuk, Bogdan ; Navrátil, Tomáš. / Voltametrické stanovení genotoxických dinitronaftalenů pomocí rtuťovým meniskem modifikované stříbrné pevné amalgámové elektrody. В: Chemicke Listy. 2007 ; Том 101, № 2. стр. 144-149.
@article{47fe70aee55741e88129784ecee6a4ba,
title = "Voltametrick{\'e} stanoven{\'i} genotoxick{\'y}ch dinitronaftalenů pomoc{\'i} rtuťov{\'y}m meniskem modifikovan{\'e} stř{\'i}brn{\'e} pevn{\'e} amalg{\'a}mov{\'e} elektrody",
abstract = "Optimum conditions are described for the determination of genotoxic 1,3-, 1,5- and 1,8-dinitronaphthalenes (DNN) by differential pulse voltammetry (DPV) on the silver solid amalgam electrode modified with a meniscus. The limits of quantification were found to be 2·10-6 mol l-1 for 1,3-DNN, 1·10-6 mol l-1 for 1,5-DNN and 5·10-7 mol l-1 for 1,8-DNN. The DNNs in submicromolar concentrations cannot be determined by adsorptive stripping voltammetry on the above electrode.",
author = "Aleš Daňhel and Karolina Peckov{\'a} and Karel Č{\'i}žek and Jiř{\'i} Barek and Jiř{\'i} Zima and Bogdan Yosypchuk and Tom{\'a}š Navr{\'a}til",
year = "2007",
month = "2",
day = "1",
language = "Slovak",
volume = "101",
pages = "144--149",
journal = "Chemicke Listy",
issn = "0009-2770",
publisher = "Czech Society of Chemical Engineering",
number = "2",

}

TY - JOUR

T1 - Voltametrické stanovení genotoxických dinitronaftalenů pomocí rtuťovým meniskem modifikované stříbrné pevné amalgámové elektrody

AU - Daňhel, Aleš

AU - Pecková, Karolina

AU - Čížek, Karel

AU - Barek, Jiří

AU - Zima, Jiří

AU - Yosypchuk, Bogdan

AU - Navrátil, Tomáš

PY - 2007/2/1

Y1 - 2007/2/1

N2 - Optimum conditions are described for the determination of genotoxic 1,3-, 1,5- and 1,8-dinitronaphthalenes (DNN) by differential pulse voltammetry (DPV) on the silver solid amalgam electrode modified with a meniscus. The limits of quantification were found to be 2·10-6 mol l-1 for 1,3-DNN, 1·10-6 mol l-1 for 1,5-DNN and 5·10-7 mol l-1 for 1,8-DNN. The DNNs in submicromolar concentrations cannot be determined by adsorptive stripping voltammetry on the above electrode.

AB - Optimum conditions are described for the determination of genotoxic 1,3-, 1,5- and 1,8-dinitronaphthalenes (DNN) by differential pulse voltammetry (DPV) on the silver solid amalgam electrode modified with a meniscus. The limits of quantification were found to be 2·10-6 mol l-1 for 1,3-DNN, 1·10-6 mol l-1 for 1,5-DNN and 5·10-7 mol l-1 for 1,8-DNN. The DNNs in submicromolar concentrations cannot be determined by adsorptive stripping voltammetry on the above electrode.

UR - http://www.scopus.com/inward/record.url?scp=33847006264&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33847006264&partnerID=8YFLogxK

M3 - Статья

AN - SCOPUS:33847006264

VL - 101

SP - 144

EP - 149

JO - Chemicke Listy

JF - Chemicke Listy

SN - 0009-2770

IS - 2

ER -