Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes

Dmytro Bavol, Jiri Zima, Jiri Barek, Hana Dejmkova

Результат исследований: Материалы для журналаСтатья

4 Цитирования (Scopus)

Выдержка

Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH4 with limit of quantification (LQ) of 5.9×10-7molL-1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH2 with LQ=1.4×10-7molL-1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.

Язык оригиналаАнглийский
Страницы (с-по)1029-1034
Число страниц6
ЖурналElectroanalysis
Том28
Номер выпуска5
DOI
СостояниеОпубликовано - 1 мая 2016
Опубликовано для внешнего пользованияДа

Отпечаток

Carbon
Voltammetry
Electrodes
Ointments
Carbon fibers
Pesticides
Rivers
Soils
2-cyano-N-((ethylamino)carbonyl)-2-(methoxyimino)acetamide
famoxadon
Water
carbon fiber

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry

Цитировать

Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes. / Bavol, Dmytro; Zima, Jiri; Barek, Jiri; Dejmkova, Hana.

В: Electroanalysis, Том 28, № 5, 01.05.2016, стр. 1029-1034.

Результат исследований: Материалы для журналаСтатья

Bavol, Dmytro ; Zima, Jiri ; Barek, Jiri ; Dejmkova, Hana. / Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes. В: Electroanalysis. 2016 ; Том 28, № 5. стр. 1029-1034.
@article{e150008312834b6a8af754593623387b,
title = "Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes",
abstract = "Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH4 with limit of quantification (LQ) of 5.9×10-7molL-1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH2 with LQ=1.4×10-7molL-1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.",
keywords = "Carbon fiber rod electrode, Carbon paste electrode, Differential pulse voltammetry, Glassy carbon electrode, Pesticide",
author = "Dmytro Bavol and Jiri Zima and Jiri Barek and Hana Dejmkova",
year = "2016",
month = "5",
day = "1",
doi = "10.1002/elan.201500633",
language = "English",
volume = "28",
pages = "1029--1034",
journal = "Macromolecular Chemistry and Physics",
issn = "1040-0397",
publisher = "Wiley-VCH Verlag",
number = "5",

}

TY - JOUR

T1 - Voltammetric Determination of Cymoxanil and Famoxadone at Different Types of Carbon Electrodes

AU - Bavol, Dmytro

AU - Zima, Jiri

AU - Barek, Jiri

AU - Dejmkova, Hana

PY - 2016/5/1

Y1 - 2016/5/1

N2 - Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH4 with limit of quantification (LQ) of 5.9×10-7molL-1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH2 with LQ=1.4×10-7molL-1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.

AB - Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH4 with limit of quantification (LQ) of 5.9×10-7molL-1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH2 with LQ=1.4×10-7molL-1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.

KW - Carbon fiber rod electrode

KW - Carbon paste electrode

KW - Differential pulse voltammetry

KW - Glassy carbon electrode

KW - Pesticide

UR - http://www.scopus.com/inward/record.url?scp=84950349869&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84950349869&partnerID=8YFLogxK

U2 - 10.1002/elan.201500633

DO - 10.1002/elan.201500633

M3 - Article

AN - SCOPUS:84950349869

VL - 28

SP - 1029

EP - 1034

JO - Macromolecular Chemistry and Physics

JF - Macromolecular Chemistry and Physics

SN - 1040-0397

IS - 5

ER -