Voltammetric determination of 3-nitrofluoranthene and 3-aminofluoranthene at boron doped diamond thin-film electrode

Karel Cizek, Jiri Barek, Jan Fischer, Karolina Peckova, Jiri Zima

Результат исследований: Материалы для журналаСтатья

33 Цитирования (Scopus)

Выдержка

The voltammetric behavior of 3-nitrofluoranthene and 3-aminofluoranthene was investigated in mixed methanol-water solutions by differential pulse voltammetry (DPV) at boron doped diamond thin-film electrode (BDDE). Optimum conditions have been found for determination of 3-nitrofluoranthene in the concentration range of 2 × 10-8-1 × 10-6 mol L-1, and for determination 3-aminofluorathnene in the concentration range of 2 x 10-7-l x 10-5 mol L-1, respectively. Limits of determination were 3 × 10-8 mol L -1 (3-nitrofluoranthene) and 2 × 10-7 mol L -1 (3-aminofluoranthene).

Язык оригиналаАнглийский
Страницы (с-по)1295-1299
Число страниц5
ЖурналElectroanalysis
Том19
Номер выпуска12
DOI
СостояниеОпубликовано - 1 июн 2007
Опубликовано для внешнего пользованияДа

Отпечаток

Boron
Diamond films
Voltammetry
Methanol
Thin films
Electrodes
Water
3-aminofluoranthene
3-nitrofluoranthene

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry

Цитировать

Voltammetric determination of 3-nitrofluoranthene and 3-aminofluoranthene at boron doped diamond thin-film electrode. / Cizek, Karel; Barek, Jiri; Fischer, Jan; Peckova, Karolina; Zima, Jiri.

В: Electroanalysis, Том 19, № 12, 01.06.2007, стр. 1295-1299.

Результат исследований: Материалы для журналаСтатья

Cizek, Karel ; Barek, Jiri ; Fischer, Jan ; Peckova, Karolina ; Zima, Jiri. / Voltammetric determination of 3-nitrofluoranthene and 3-aminofluoranthene at boron doped diamond thin-film electrode. В: Electroanalysis. 2007 ; Том 19, № 12. стр. 1295-1299.
@article{0e6c37b7a7d04617bdeac08a17643558,
title = "Voltammetric determination of 3-nitrofluoranthene and 3-aminofluoranthene at boron doped diamond thin-film electrode",
abstract = "The voltammetric behavior of 3-nitrofluoranthene and 3-aminofluoranthene was investigated in mixed methanol-water solutions by differential pulse voltammetry (DPV) at boron doped diamond thin-film electrode (BDDE). Optimum conditions have been found for determination of 3-nitrofluoranthene in the concentration range of 2 × 10-8-1 × 10-6 mol L-1, and for determination 3-aminofluorathnene in the concentration range of 2 x 10-7-l x 10-5 mol L-1, respectively. Limits of determination were 3 × 10-8 mol L -1 (3-nitrofluoranthene) and 2 × 10-7 mol L -1 (3-aminofluoranthene).",
keywords = "3-Aminofluoranthene, 3-Nitrofluoranthene, Boron doped diamond thin-film electrode, Differential pulse voltammetry",
author = "Karel Cizek and Jiri Barek and Jan Fischer and Karolina Peckova and Jiri Zima",
year = "2007",
month = "6",
day = "1",
doi = "10.1002/elan.200603851",
language = "English",
volume = "19",
pages = "1295--1299",
journal = "Macromolecular Chemistry and Physics",
issn = "1040-0397",
publisher = "Wiley-VCH Verlag",
number = "12",

}

TY - JOUR

T1 - Voltammetric determination of 3-nitrofluoranthene and 3-aminofluoranthene at boron doped diamond thin-film electrode

AU - Cizek, Karel

AU - Barek, Jiri

AU - Fischer, Jan

AU - Peckova, Karolina

AU - Zima, Jiri

PY - 2007/6/1

Y1 - 2007/6/1

N2 - The voltammetric behavior of 3-nitrofluoranthene and 3-aminofluoranthene was investigated in mixed methanol-water solutions by differential pulse voltammetry (DPV) at boron doped diamond thin-film electrode (BDDE). Optimum conditions have been found for determination of 3-nitrofluoranthene in the concentration range of 2 × 10-8-1 × 10-6 mol L-1, and for determination 3-aminofluorathnene in the concentration range of 2 x 10-7-l x 10-5 mol L-1, respectively. Limits of determination were 3 × 10-8 mol L -1 (3-nitrofluoranthene) and 2 × 10-7 mol L -1 (3-aminofluoranthene).

AB - The voltammetric behavior of 3-nitrofluoranthene and 3-aminofluoranthene was investigated in mixed methanol-water solutions by differential pulse voltammetry (DPV) at boron doped diamond thin-film electrode (BDDE). Optimum conditions have been found for determination of 3-nitrofluoranthene in the concentration range of 2 × 10-8-1 × 10-6 mol L-1, and for determination 3-aminofluorathnene in the concentration range of 2 x 10-7-l x 10-5 mol L-1, respectively. Limits of determination were 3 × 10-8 mol L -1 (3-nitrofluoranthene) and 2 × 10-7 mol L -1 (3-aminofluoranthene).

KW - 3-Aminofluoranthene

KW - 3-Nitrofluoranthene

KW - Boron doped diamond thin-film electrode

KW - Differential pulse voltammetry

UR - http://www.scopus.com/inward/record.url?scp=34547591930&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34547591930&partnerID=8YFLogxK

U2 - 10.1002/elan.200603851

DO - 10.1002/elan.200603851

M3 - Article

AN - SCOPUS:34547591930

VL - 19

SP - 1295

EP - 1299

JO - Macromolecular Chemistry and Physics

JF - Macromolecular Chemistry and Physics

SN - 1040-0397

IS - 12

ER -