Voltametrické stanovení 1-nitropyrenu a 1-aminopyrenu na borem dopované diamantové filmové elektrodě

Oksana Yosypchuk, Karolina Pecková, Jiří Barek

Результат исследований: Материалы для журналаСтатья

9 Цитирования (Scopus)

Аннотация

Optimum conditions for the determination of carcinogenic 1-nitropyrene (NP) and 1-aminopyrene (AP) by differential pulse voltammetry with a boron-doped diamond film electrode were found - aqueous-methanolic (3:7) Britton-Robinson buffer (pH 3), scan rate 20 mV s-1, pulse duration 100 ms, pulse amplitude -50 mV (NP) and 50 mV (AP). The regeneration in NP determination was carried out before analysis by switching fifty-times between the potentials 800 mV and -500 mV every 0.3 s. In determination of AP, no regeneration was needed. The limits of quantification were 8·10-7 and 2·10-7 mol dm-3 for NP and AP, respectively.

Переведенное названиеVoltammetric determination of 1-nitropyrene and 1-aminopyrene at a boron-doped diamond film electrode
Язык оригиналаCzech
Страницы (с-по)186-190
Число страниц5
ЖурналChemicke Listy
Том104
Номер выпуска3
СостояниеОпубликовано - 16 мар 2010
Опубликовано для внешнего пользованияДа

ASJC Scopus subject areas

  • Chemistry(all)

Fingerprint Подробные сведения о темах исследования «Voltametrické stanovení 1-nitropyrenu a 1-aminopyrenu na borem dopované diamantové filmové elektrodě». Вместе они формируют уникальный семантический отпечаток (fingerprint).

  • Цитировать