The influence of skin-electrode contact on the quality of ECG recording for personal telemedicine systems

I. A. Lezhnina, A. A. Boyakhchyan, M. A. Ivanov, M. I. Samolutchenko

Результат исследований: Материалы для журнала

Выдержка

In this article are presented the results of the study of the Tele-ECG system. Presented system automatically records the ECG signal and transmits it to the server, where occurs process of the decryption (automatic detection of R-waves and ST-segments on the ECG). A distinctive feature of the system is the use of it includes devices with capacitive sensors. The results quality research of the signal received through different dielectrics. The necessity of revision of sensors that will allow to avoid the interference caused by man and external factors. As a result, this refinement will allow to receive a signal for automatic diagnostics with the least loss of information due to the presence of interference in the signal.

Язык оригиналаАнглийский
Номер статьи012048
ЖурналIOP Conference Series: Materials Science and Engineering
Том516
Номер выпуска1
DOI
СостояниеОпубликовано - 26 апр 2019
Событие3rd International Conference on Cognitive Robotics - Tomsk, Российская Федерация
Продолжительность: 22 ноя 201824 ноя 2018

Отпечаток

Telemedicine
Electrocardiography
Skin
Electrodes
Capacitive sensors
Servers
Sensors

ASJC Scopus subject areas

  • Materials Science(all)
  • Engineering(all)

Цитировать

The influence of skin-electrode contact on the quality of ECG recording for personal telemedicine systems. / Lezhnina, I. A.; Boyakhchyan, A. A.; Ivanov, M. A.; Samolutchenko, M. I.

В: IOP Conference Series: Materials Science and Engineering, Том 516, № 1, 012048, 26.04.2019.

Результат исследований: Материалы для журнала

@article{45e987f2f40444188de93fc52c58d650,
title = "The influence of skin-electrode contact on the quality of ECG recording for personal telemedicine systems",
abstract = "In this article are presented the results of the study of the Tele-ECG system. Presented system automatically records the ECG signal and transmits it to the server, where occurs process of the decryption (automatic detection of R-waves and ST-segments on the ECG). A distinctive feature of the system is the use of it includes devices with capacitive sensors. The results quality research of the signal received through different dielectrics. The necessity of revision of sensors that will allow to avoid the interference caused by man and external factors. As a result, this refinement will allow to receive a signal for automatic diagnostics with the least loss of information due to the presence of interference in the signal.",
author = "Lezhnina, {I. A.} and Boyakhchyan, {A. A.} and Ivanov, {M. A.} and Samolutchenko, {M. I.}",
year = "2019",
month = "4",
day = "26",
doi = "10.1088/1757-899X/516/1/012048",
language = "English",
volume = "516",
journal = "IOP Conference Series: Materials Science and Engineering",
issn = "1757-8981",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - The influence of skin-electrode contact on the quality of ECG recording for personal telemedicine systems

AU - Lezhnina, I. A.

AU - Boyakhchyan, A. A.

AU - Ivanov, M. A.

AU - Samolutchenko, M. I.

PY - 2019/4/26

Y1 - 2019/4/26

N2 - In this article are presented the results of the study of the Tele-ECG system. Presented system automatically records the ECG signal and transmits it to the server, where occurs process of the decryption (automatic detection of R-waves and ST-segments on the ECG). A distinctive feature of the system is the use of it includes devices with capacitive sensors. The results quality research of the signal received through different dielectrics. The necessity of revision of sensors that will allow to avoid the interference caused by man and external factors. As a result, this refinement will allow to receive a signal for automatic diagnostics with the least loss of information due to the presence of interference in the signal.

AB - In this article are presented the results of the study of the Tele-ECG system. Presented system automatically records the ECG signal and transmits it to the server, where occurs process of the decryption (automatic detection of R-waves and ST-segments on the ECG). A distinctive feature of the system is the use of it includes devices with capacitive sensors. The results quality research of the signal received through different dielectrics. The necessity of revision of sensors that will allow to avoid the interference caused by man and external factors. As a result, this refinement will allow to receive a signal for automatic diagnostics with the least loss of information due to the presence of interference in the signal.

UR - http://www.scopus.com/inward/record.url?scp=85065621221&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85065621221&partnerID=8YFLogxK

U2 - 10.1088/1757-899X/516/1/012048