The Development of Equipment for the Disposal of Solid Organic Waste and Optimization of Its Operation

Almaz R. Sadrtdinov, Rushan G. Safin, Nail F. Timerbaev, Dilyara F. Ziatdinova, Natalya A. Saprykina

Результат исследований: Материалы для журналаСтатья

13 Цитирования (Scopus)

Выдержка

The paper describes the developed system for the thermal utilization of solid organic waste, which can simultaneously process the paper, wood, rubber, plastic, etc. A method for improving the efficiency of the equipment, due to optimization of the gas extraction system was proposed. The influence of the characteristics of installed equipment and modes of their work on energy savings and efficiency of the gas extraction system was also determined. Optimization work which includes the introduction into the exhauster control system of the frequency converter, can save up to 70% of electricity and increases the life of the equipment.

Язык оригиналаАнглийский
Номер статьи012095
ЖурналIOP Conference Series: Materials Science and Engineering
Том142
Номер выпуска1
DOI
СостояниеОпубликовано - 2 сен 2016

Отпечаток

Waste disposal
Gases
Frequency converters
Rubber
Energy efficiency
Wood
Energy conservation
Electricity
Plastics
Control systems

ASJC Scopus subject areas

  • Materials Science(all)
  • Engineering(all)

Цитировать

The Development of Equipment for the Disposal of Solid Organic Waste and Optimization of Its Operation. / Sadrtdinov, Almaz R.; Safin, Rushan G.; Timerbaev, Nail F.; Ziatdinova, Dilyara F.; Saprykina, Natalya A.

В: IOP Conference Series: Materials Science and Engineering, Том 142, № 1, 012095, 02.09.2016.

Результат исследований: Материалы для журналаСтатья

@article{c55dde62ae7b49438e52b7c0bc2a0db7,
title = "The Development of Equipment for the Disposal of Solid Organic Waste and Optimization of Its Operation",
abstract = "The paper describes the developed system for the thermal utilization of solid organic waste, which can simultaneously process the paper, wood, rubber, plastic, etc. A method for improving the efficiency of the equipment, due to optimization of the gas extraction system was proposed. The influence of the characteristics of installed equipment and modes of their work on energy savings and efficiency of the gas extraction system was also determined. Optimization work which includes the introduction into the exhauster control system of the frequency converter, can save up to 70{\%} of electricity and increases the life of the equipment.",
author = "Sadrtdinov, {Almaz R.} and Safin, {Rushan G.} and Timerbaev, {Nail F.} and Ziatdinova, {Dilyara F.} and Saprykina, {Natalya A.}",
year = "2016",
month = "9",
day = "2",
doi = "10.1088/1757-899X/142/1/012095",
language = "English",
volume = "142",
journal = "IOP Conference Series: Materials Science and Engineering",
issn = "1757-8981",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - The Development of Equipment for the Disposal of Solid Organic Waste and Optimization of Its Operation

AU - Sadrtdinov, Almaz R.

AU - Safin, Rushan G.

AU - Timerbaev, Nail F.

AU - Ziatdinova, Dilyara F.

AU - Saprykina, Natalya A.

PY - 2016/9/2

Y1 - 2016/9/2

N2 - The paper describes the developed system for the thermal utilization of solid organic waste, which can simultaneously process the paper, wood, rubber, plastic, etc. A method for improving the efficiency of the equipment, due to optimization of the gas extraction system was proposed. The influence of the characteristics of installed equipment and modes of their work on energy savings and efficiency of the gas extraction system was also determined. Optimization work which includes the introduction into the exhauster control system of the frequency converter, can save up to 70% of electricity and increases the life of the equipment.

AB - The paper describes the developed system for the thermal utilization of solid organic waste, which can simultaneously process the paper, wood, rubber, plastic, etc. A method for improving the efficiency of the equipment, due to optimization of the gas extraction system was proposed. The influence of the characteristics of installed equipment and modes of their work on energy savings and efficiency of the gas extraction system was also determined. Optimization work which includes the introduction into the exhauster control system of the frequency converter, can save up to 70% of electricity and increases the life of the equipment.

UR - http://www.scopus.com/inward/record.url?scp=84988464601&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84988464601&partnerID=8YFLogxK

U2 - 10.1088/1757-899X/142/1/012095

DO - 10.1088/1757-899X/142/1/012095

M3 - Article

AN - SCOPUS:84988464601

VL - 142

JO - IOP Conference Series: Materials Science and Engineering

JF - IOP Conference Series: Materials Science and Engineering

SN - 1757-8981

IS - 1

M1 - 012095

ER -