Аннотация
Results of the experimental investigation of the resonant microwave pulse compression system operating in a 10-cm wavelength region are presented. The system contains two multimode resonators for storing high-frequency energy and a waveguide bridge for the fast and synchronous energy extraction. When powered from a magnetron generator having a radiation power of 5 MW and pulse duration of 4 μs, microwave pulses with an output power of ∼0.8 GW, duration of ∼5 ns, and pulse repetition rate up to 100 Hz were obtained in this compression system.
Язык оригинала | Английский |
---|---|
Страницы (с-по) | 174-177 |
Число страниц | 4 |
Журнал | Instruments and Experimental Techniques |
Том | 56 |
Номер выпуска | 2 |
DOI | |
Состояние | Опубликовано - 1 мар 2013 |
ASJC Scopus subject areas
- Instrumentation