Sub-micrometre resolution laserwire transverse beam size measurement system

L. J. Nevay, S. T. Boogert, P. Karataev, K. Kruchinin, L. Corner, R. Walczak, A. Aryshev, J. Urakawa, N. Terunuma

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Выдержка

The laserwire system at the Accelerator Test Facility 2 (ATF2) is a transverse beam profile measurement system capable of measuring a micrometre-size electron beam. We present recent results demonstrating a measured vertical size of 1.16 ± 0.06 μm and a horizontal size of 110.1 ± 3.8 μ m. Due to the high aspect ratio of the electron beam, the natural divergence of the tightly focussed laser beam across the electron beam width requires the use of the full overlap integral to deconvolve the scans. For this to be done accurately, the propagation of the 150 mJ, 167 ps long laser pulses was precisely measured at a scaled virtual interaction point.

Язык оригиналаАнглийский
Название основной публикацииIBIC 2013
Подзаголовок основной публикацииProceedings of the 2nd International Beam Instrumentation Conference
ИздательJoint Accelerator Conferences Website (JACoW)
Страницы243-246
Число страниц4
ISBN (электронное издание)9783954501274
СостояниеОпубликовано - 1 дек 2013
Опубликовано для внешнего пользованияДа
Событие2nd International Beam Instrumentation Conference, IBIC 2013 - Oxford, Великобритания
Продолжительность: 16 сен 201319 сен 2013

Конференция

Конференция2nd International Beam Instrumentation Conference, IBIC 2013
СтранаВеликобритания
ГородOxford
Период16.9.1319.9.13

Отпечаток

micrometers
Electron beams
electron beams
test facilities
Test facilities
high aspect ratio
Particle accelerators
Laser beams
Aspect ratio
Laser pulses
divergence
accelerators
laser beams
propagation
profiles
pulses
lasers
interactions

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Цитировать

Nevay, L. J., Boogert, S. T., Karataev, P., Kruchinin, K., Corner, L., Walczak, R., ... Terunuma, N. (2013). Sub-micrometre resolution laserwire transverse beam size measurement system. В IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference (стр. 243-246). Joint Accelerator Conferences Website (JACoW).

Sub-micrometre resolution laserwire transverse beam size measurement system. / Nevay, L. J.; Boogert, S. T.; Karataev, P.; Kruchinin, K.; Corner, L.; Walczak, R.; Aryshev, A.; Urakawa, J.; Terunuma, N.

IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference. Joint Accelerator Conferences Website (JACoW), 2013. стр. 243-246.

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Nevay, LJ, Boogert, ST, Karataev, P, Kruchinin, K, Corner, L, Walczak, R, Aryshev, A, Urakawa, J & Terunuma, N 2013, Sub-micrometre resolution laserwire transverse beam size measurement system. в IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference. Joint Accelerator Conferences Website (JACoW), стр. 243-246, Oxford, Великобритания, 16.9.13.
Nevay LJ, Boogert ST, Karataev P, Kruchinin K, Corner L, Walczak R и соавт. Sub-micrometre resolution laserwire transverse beam size measurement system. В IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference. Joint Accelerator Conferences Website (JACoW). 2013. стр. 243-246
Nevay, L. J. ; Boogert, S. T. ; Karataev, P. ; Kruchinin, K. ; Corner, L. ; Walczak, R. ; Aryshev, A. ; Urakawa, J. ; Terunuma, N. / Sub-micrometre resolution laserwire transverse beam size measurement system. IBIC 2013: Proceedings of the 2nd International Beam Instrumentation Conference. Joint Accelerator Conferences Website (JACoW), 2013. стр. 243-246
@inproceedings{4ffe3c007b414519a1e1f70b576ab224,
title = "Sub-micrometre resolution laserwire transverse beam size measurement system",
abstract = "The laserwire system at the Accelerator Test Facility 2 (ATF2) is a transverse beam profile measurement system capable of measuring a micrometre-size electron beam. We present recent results demonstrating a measured vertical size of 1.16 ± 0.06 μm and a horizontal size of 110.1 ± 3.8 μ m. Due to the high aspect ratio of the electron beam, the natural divergence of the tightly focussed laser beam across the electron beam width requires the use of the full overlap integral to deconvolve the scans. For this to be done accurately, the propagation of the 150 mJ, 167 ps long laser pulses was precisely measured at a scaled virtual interaction point.",
author = "Nevay, {L. J.} and Boogert, {S. T.} and P. Karataev and K. Kruchinin and L. Corner and R. Walczak and A. Aryshev and J. Urakawa and N. Terunuma",
year = "2013",
month = "12",
day = "1",
language = "English",
pages = "243--246",
booktitle = "IBIC 2013",
publisher = "Joint Accelerator Conferences Website (JACoW)",

}

TY - GEN

T1 - Sub-micrometre resolution laserwire transverse beam size measurement system

AU - Nevay, L. J.

AU - Boogert, S. T.

AU - Karataev, P.

AU - Kruchinin, K.

AU - Corner, L.

AU - Walczak, R.

AU - Aryshev, A.

AU - Urakawa, J.

AU - Terunuma, N.

PY - 2013/12/1

Y1 - 2013/12/1

N2 - The laserwire system at the Accelerator Test Facility 2 (ATF2) is a transverse beam profile measurement system capable of measuring a micrometre-size electron beam. We present recent results demonstrating a measured vertical size of 1.16 ± 0.06 μm and a horizontal size of 110.1 ± 3.8 μ m. Due to the high aspect ratio of the electron beam, the natural divergence of the tightly focussed laser beam across the electron beam width requires the use of the full overlap integral to deconvolve the scans. For this to be done accurately, the propagation of the 150 mJ, 167 ps long laser pulses was precisely measured at a scaled virtual interaction point.

AB - The laserwire system at the Accelerator Test Facility 2 (ATF2) is a transverse beam profile measurement system capable of measuring a micrometre-size electron beam. We present recent results demonstrating a measured vertical size of 1.16 ± 0.06 μm and a horizontal size of 110.1 ± 3.8 μ m. Due to the high aspect ratio of the electron beam, the natural divergence of the tightly focussed laser beam across the electron beam width requires the use of the full overlap integral to deconvolve the scans. For this to be done accurately, the propagation of the 150 mJ, 167 ps long laser pulses was precisely measured at a scaled virtual interaction point.

UR - http://www.scopus.com/inward/record.url?scp=84920545310&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84920545310&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84920545310

SP - 243

EP - 246

BT - IBIC 2013

PB - Joint Accelerator Conferences Website (JACoW)

ER -