Spatial distribution of PXR generated by 855 MeV electrons: Comparison of simulation results with experimental data

Yu A. Goponov, M. A. Sidnin, I. E. Vnukov, C. Behrens, G. Kube, W. Lauth, A. S. Gogolev, A. P. Potylitsyn

Результат исследований: Материалы для журналаСтатья

2 Цитирования (Scopus)

Выдержка

The detailed data treatment of the experiment performed in MAMI-B microtron with the X-ray camera, taking into account the contribution of both diffracted transition radiation and bremsstrahlung, is presented. The X-ray camera efficiency was additionally considered. The simulated emission pattern in general agrees with the experimental one. However, along the Bragg direction where the influence of the beam size on the emission spatial distribution is most noticeable, a discrepancy between the model and the experiment is observed. Possible reasons of such discrepancy are discussed.

Язык оригиналаАнглийский
Страницы (с-по)83-87
Число страниц5
ЖурналNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
Том402
DOI
СостояниеОпубликовано - 1 июл 2017

Отпечаток

X ray cameras
Spatial distribution
spatial distribution
cameras
Electrons
bremsstrahlung
electrons
x rays
simulation
Experiments
Radiation
radiation

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Цитировать

Spatial distribution of PXR generated by 855 MeV electrons : Comparison of simulation results with experimental data. / Goponov, Yu A.; Sidnin, M. A.; Vnukov, I. E.; Behrens, C.; Kube, G.; Lauth, W.; Gogolev, A. S.; Potylitsyn, A. P.

В: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, Том 402, 01.07.2017, стр. 83-87.

Результат исследований: Материалы для журналаСтатья

@article{11acd2935d904af98cf262437321fb5e,
title = "Spatial distribution of PXR generated by 855 MeV electrons: Comparison of simulation results with experimental data",
abstract = "The detailed data treatment of the experiment performed in MAMI-B microtron with the X-ray camera, taking into account the contribution of both diffracted transition radiation and bremsstrahlung, is presented. The X-ray camera efficiency was additionally considered. The simulated emission pattern in general agrees with the experimental one. However, along the Bragg direction where the influence of the beam size on the emission spatial distribution is most noticeable, a discrepancy between the model and the experiment is observed. Possible reasons of such discrepancy are discussed.",
keywords = "Accelerator, Beam diagnostics, Crystal, Parametric X-ray radiation",
author = "Goponov, {Yu A.} and Sidnin, {M. A.} and Vnukov, {I. E.} and C. Behrens and G. Kube and W. Lauth and Gogolev, {A. S.} and Potylitsyn, {A. P.}",
year = "2017",
month = "7",
day = "1",
doi = "10.1016/j.nimb.2017.03.006",
language = "English",
volume = "402",
pages = "83--87",
journal = "Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms",
issn = "0168-583X",
publisher = "Elsevier",

}

TY - JOUR

T1 - Spatial distribution of PXR generated by 855 MeV electrons

T2 - Comparison of simulation results with experimental data

AU - Goponov, Yu A.

AU - Sidnin, M. A.

AU - Vnukov, I. E.

AU - Behrens, C.

AU - Kube, G.

AU - Lauth, W.

AU - Gogolev, A. S.

AU - Potylitsyn, A. P.

PY - 2017/7/1

Y1 - 2017/7/1

N2 - The detailed data treatment of the experiment performed in MAMI-B microtron with the X-ray camera, taking into account the contribution of both diffracted transition radiation and bremsstrahlung, is presented. The X-ray camera efficiency was additionally considered. The simulated emission pattern in general agrees with the experimental one. However, along the Bragg direction where the influence of the beam size on the emission spatial distribution is most noticeable, a discrepancy between the model and the experiment is observed. Possible reasons of such discrepancy are discussed.

AB - The detailed data treatment of the experiment performed in MAMI-B microtron with the X-ray camera, taking into account the contribution of both diffracted transition radiation and bremsstrahlung, is presented. The X-ray camera efficiency was additionally considered. The simulated emission pattern in general agrees with the experimental one. However, along the Bragg direction where the influence of the beam size on the emission spatial distribution is most noticeable, a discrepancy between the model and the experiment is observed. Possible reasons of such discrepancy are discussed.

KW - Accelerator

KW - Beam diagnostics

KW - Crystal

KW - Parametric X-ray radiation

UR - http://www.scopus.com/inward/record.url?scp=85014513586&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85014513586&partnerID=8YFLogxK

U2 - 10.1016/j.nimb.2017.03.006

DO - 10.1016/j.nimb.2017.03.006

M3 - Article

AN - SCOPUS:85014513586

VL - 402

SP - 83

EP - 87

JO - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

JF - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

SN - 0168-583X

ER -