Simultaneous voltammetric determination of nitrites and nitrates in waters

O. V. Kaminskaya, E. A. Zakharova, G. B. Slepchenko

Результат исследований: Материалы для журналаСтатья

11 Цитирования (Scopus)

Выдержка

A rapid procedure was developed for the simultaneous voltammetric determination of nitrites and nitrates from a single sample of potable, mineral, or underground water. Nitrites were first determined upon the anodic polarization of a graphite electrode in a sodium sulfate supporting electrolyte. Next, ascorbic acid and a copper salt were added, and the solution was acidified to an optimum pH value. A copper electrode was formed in situ, and the nitrate signal was recorded as the first derivative using cathodic sweep. The procedure does not require sample preparation or oxygen removal from the solution with a nitrogen flow. The copper-graphite electrode was regenerated electrochemically in the same solution. The analytical range for nitrite ions was 0.2-10.0 mg/L in the presence of any amount of nitrates. Nitrates were quantitatively determined in the range 0.5-5 mg/L. Common cations and anions in waters did not interfere with the determination. The procedure is suitable for the analysis of potable, mineral, underground, and surface waters. The procedure was verified by the added-found method and by the photometric procedure GOST (State Standard) 18826-73.

Язык оригиналаАнглийский
Страницы (с-по)1091-1096
Число страниц6
ЖурналJournal of Analytical Chemistry
Том59
Номер выпуска11
DOI
СостояниеОпубликовано - ноя 2004

Отпечаток

Nitrites
Nitrates
Copper
Graphite electrodes
Water
Minerals
Groundwater
Anodic polarization
Surface waters
Electrolytes
Ascorbic Acid
Anions
Cations
Nitrogen
Salts
Ions
Oxygen
Derivatives
Electrodes

ASJC Scopus subject areas

  • Analytical Chemistry

Цитировать

Simultaneous voltammetric determination of nitrites and nitrates in waters. / Kaminskaya, O. V.; Zakharova, E. A.; Slepchenko, G. B.

В: Journal of Analytical Chemistry, Том 59, № 11, 11.2004, стр. 1091-1096.

Результат исследований: Материалы для журналаСтатья

Kaminskaya, O. V. ; Zakharova, E. A. ; Slepchenko, G. B. / Simultaneous voltammetric determination of nitrites and nitrates in waters. В: Journal of Analytical Chemistry. 2004 ; Том 59, № 11. стр. 1091-1096.
@article{be391ea0c33146e9a3e16246c61b10bb,
title = "Simultaneous voltammetric determination of nitrites and nitrates in waters",
abstract = "A rapid procedure was developed for the simultaneous voltammetric determination of nitrites and nitrates from a single sample of potable, mineral, or underground water. Nitrites were first determined upon the anodic polarization of a graphite electrode in a sodium sulfate supporting electrolyte. Next, ascorbic acid and a copper salt were added, and the solution was acidified to an optimum pH value. A copper electrode was formed in situ, and the nitrate signal was recorded as the first derivative using cathodic sweep. The procedure does not require sample preparation or oxygen removal from the solution with a nitrogen flow. The copper-graphite electrode was regenerated electrochemically in the same solution. The analytical range for nitrite ions was 0.2-10.0 mg/L in the presence of any amount of nitrates. Nitrates were quantitatively determined in the range 0.5-5 mg/L. Common cations and anions in waters did not interfere with the determination. The procedure is suitable for the analysis of potable, mineral, underground, and surface waters. The procedure was verified by the added-found method and by the photometric procedure GOST (State Standard) 18826-73.",
author = "Kaminskaya, {O. V.} and Zakharova, {E. A.} and Slepchenko, {G. B.}",
year = "2004",
month = "11",
doi = "10.1023/B:JANC.0000047013.71862.c4",
language = "English",
volume = "59",
pages = "1091--1096",
journal = "Journal of Analytical Chemistry",
issn = "1061-9348",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "11",

}

TY - JOUR

T1 - Simultaneous voltammetric determination of nitrites and nitrates in waters

AU - Kaminskaya, O. V.

AU - Zakharova, E. A.

AU - Slepchenko, G. B.

PY - 2004/11

Y1 - 2004/11

N2 - A rapid procedure was developed for the simultaneous voltammetric determination of nitrites and nitrates from a single sample of potable, mineral, or underground water. Nitrites were first determined upon the anodic polarization of a graphite electrode in a sodium sulfate supporting electrolyte. Next, ascorbic acid and a copper salt were added, and the solution was acidified to an optimum pH value. A copper electrode was formed in situ, and the nitrate signal was recorded as the first derivative using cathodic sweep. The procedure does not require sample preparation or oxygen removal from the solution with a nitrogen flow. The copper-graphite electrode was regenerated electrochemically in the same solution. The analytical range for nitrite ions was 0.2-10.0 mg/L in the presence of any amount of nitrates. Nitrates were quantitatively determined in the range 0.5-5 mg/L. Common cations and anions in waters did not interfere with the determination. The procedure is suitable for the analysis of potable, mineral, underground, and surface waters. The procedure was verified by the added-found method and by the photometric procedure GOST (State Standard) 18826-73.

AB - A rapid procedure was developed for the simultaneous voltammetric determination of nitrites and nitrates from a single sample of potable, mineral, or underground water. Nitrites were first determined upon the anodic polarization of a graphite electrode in a sodium sulfate supporting electrolyte. Next, ascorbic acid and a copper salt were added, and the solution was acidified to an optimum pH value. A copper electrode was formed in situ, and the nitrate signal was recorded as the first derivative using cathodic sweep. The procedure does not require sample preparation or oxygen removal from the solution with a nitrogen flow. The copper-graphite electrode was regenerated electrochemically in the same solution. The analytical range for nitrite ions was 0.2-10.0 mg/L in the presence of any amount of nitrates. Nitrates were quantitatively determined in the range 0.5-5 mg/L. Common cations and anions in waters did not interfere with the determination. The procedure is suitable for the analysis of potable, mineral, underground, and surface waters. The procedure was verified by the added-found method and by the photometric procedure GOST (State Standard) 18826-73.

UR - http://www.scopus.com/inward/record.url?scp=8644290863&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=8644290863&partnerID=8YFLogxK

U2 - 10.1023/B:JANC.0000047013.71862.c4

DO - 10.1023/B:JANC.0000047013.71862.c4

M3 - Article

AN - SCOPUS:8644290863

VL - 59

SP - 1091

EP - 1096

JO - Journal of Analytical Chemistry

JF - Journal of Analytical Chemistry

SN - 1061-9348

IS - 11

ER -