Setting the Delay of the LTD Switch Firing Using Trigger Inductors

V. M. Alexeenko, V. A. Sinebryukhov, S. S. Kondratiev, S. N. Volkov, A. A. Kim, V. Yu Yakovlev

Результат исследований: Материалы для журналаСтатья

2 Цитирования (Scopus)

Выдержка

Simulation results are compared with experimental data to define the integral breakdown criterion for the spark gaps of the switches of the LTDs with oil insulation and to determine the influence of the inductance of the trigger inductor on the delay of the switch firing. The results confirm that the shape of the output square pulse produced by the oil-insulated LTDs can be corrected as required if the trigger inductors are used to trigger the cavity switches.

Язык оригиналаАнглийский
Страницы (с-по)1553-1558
Число страниц6
ЖурналRussian Physics Journal
Том60
Номер выпуска9
DOI
СостояниеОпубликовано - 1 янв 2018
Опубликовано для внешнего пользованияДа

Отпечаток

inductors
switches
actuators
oils
spark gaps
inductance
insulation
breakdown
cavities
output
pulses
simulation

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Цитировать

Alexeenko, V. M., Sinebryukhov, V. A., Kondratiev, S. S., Volkov, S. N., Kim, A. A., & Yakovlev, V. Y. (2018). Setting the Delay of the LTD Switch Firing Using Trigger Inductors. Russian Physics Journal, 60(9), 1553-1558. https://doi.org/10.1007/s11182-018-1250-8

Setting the Delay of the LTD Switch Firing Using Trigger Inductors. / Alexeenko, V. M.; Sinebryukhov, V. A.; Kondratiev, S. S.; Volkov, S. N.; Kim, A. A.; Yakovlev, V. Yu.

В: Russian Physics Journal, Том 60, № 9, 01.01.2018, стр. 1553-1558.

Результат исследований: Материалы для журналаСтатья

Alexeenko, VM, Sinebryukhov, VA, Kondratiev, SS, Volkov, SN, Kim, AA & Yakovlev, VY 2018, 'Setting the Delay of the LTD Switch Firing Using Trigger Inductors', Russian Physics Journal, том. 60, № 9, стр. 1553-1558. https://doi.org/10.1007/s11182-018-1250-8
Alexeenko VM, Sinebryukhov VA, Kondratiev SS, Volkov SN, Kim AA, Yakovlev VY. Setting the Delay of the LTD Switch Firing Using Trigger Inductors. Russian Physics Journal. 2018 Янв. 1;60(9):1553-1558. https://doi.org/10.1007/s11182-018-1250-8
Alexeenko, V. M. ; Sinebryukhov, V. A. ; Kondratiev, S. S. ; Volkov, S. N. ; Kim, A. A. ; Yakovlev, V. Yu. / Setting the Delay of the LTD Switch Firing Using Trigger Inductors. В: Russian Physics Journal. 2018 ; Том 60, № 9. стр. 1553-1558.
@article{38de9833c3eb4a6b896cf4facc1d9860,
title = "Setting the Delay of the LTD Switch Firing Using Trigger Inductors",
abstract = "Simulation results are compared with experimental data to define the integral breakdown criterion for the spark gaps of the switches of the LTDs with oil insulation and to determine the influence of the inductance of the trigger inductor on the delay of the switch firing. The results confirm that the shape of the output square pulse produced by the oil-insulated LTDs can be corrected as required if the trigger inductors are used to trigger the cavity switches.",
keywords = "high-pressure spark-gap switch, LTD technology, trigger inductors, trigger resistors",
author = "Alexeenko, {V. M.} and Sinebryukhov, {V. A.} and Kondratiev, {S. S.} and Volkov, {S. N.} and Kim, {A. A.} and Yakovlev, {V. Yu}",
year = "2018",
month = "1",
day = "1",
doi = "10.1007/s11182-018-1250-8",
language = "English",
volume = "60",
pages = "1553--1558",
journal = "Russian Physics Journal",
issn = "1064-8887",
publisher = "Consultants Bureau",
number = "9",

}

TY - JOUR

T1 - Setting the Delay of the LTD Switch Firing Using Trigger Inductors

AU - Alexeenko, V. M.

AU - Sinebryukhov, V. A.

AU - Kondratiev, S. S.

AU - Volkov, S. N.

AU - Kim, A. A.

AU - Yakovlev, V. Yu

PY - 2018/1/1

Y1 - 2018/1/1

N2 - Simulation results are compared with experimental data to define the integral breakdown criterion for the spark gaps of the switches of the LTDs with oil insulation and to determine the influence of the inductance of the trigger inductor on the delay of the switch firing. The results confirm that the shape of the output square pulse produced by the oil-insulated LTDs can be corrected as required if the trigger inductors are used to trigger the cavity switches.

AB - Simulation results are compared with experimental data to define the integral breakdown criterion for the spark gaps of the switches of the LTDs with oil insulation and to determine the influence of the inductance of the trigger inductor on the delay of the switch firing. The results confirm that the shape of the output square pulse produced by the oil-insulated LTDs can be corrected as required if the trigger inductors are used to trigger the cavity switches.

KW - high-pressure spark-gap switch

KW - LTD technology

KW - trigger inductors

KW - trigger resistors

UR - http://www.scopus.com/inward/record.url?scp=85040902930&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85040902930&partnerID=8YFLogxK

U2 - 10.1007/s11182-018-1250-8

DO - 10.1007/s11182-018-1250-8

M3 - Article

AN - SCOPUS:85040902930

VL - 60

SP - 1553

EP - 1558

JO - Russian Physics Journal

JF - Russian Physics Journal

SN - 1064-8887

IS - 9

ER -