Sensorless determination of initial position of the rotor of permanent-magnet synchronous motor of the gearless elevator hoist

I. Yu Krasnov, S. V. Langraf, I. G. Odnokopylov, Y. V. Krokhta, N. M. Natalinova, O. V. Galtseva, A. A. Rogachev

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Выдержка

Currently the special algorithms are used to determinate an initial position of rotor angle of the permanent magnet synchronous drives. This is especially important for providing of smooth load at the electric drive starting, for example, for gearless elevator hoist drive. For this the position sensors are used in simple electrical drives, but system cost is increased. Paper describes a developed new algorithm, which determines an absolute angular position of rotor of the permanent magnet synchronous motor. Stator is magnetized by leakage currents of windings at applying the specific voltage pulses to the motor. This algorithm allows calculating absolute position of the rotor in practice. The main advantage of presented algorithm is a functioning without motor parameters. Simplicity and algorithm efficiency are confirmed by obtained experiment results by simulation for determination of initial position of rotor of the permanent magnet synchronous motor. Therefore, this method can be widely used by engineers of electrical industry.

Язык оригиналаАнглийский
Название основной публикации2017 International Siberian Conference on Control and Communications, SIBCON 2017 - Proceedings
ИздательInstitute of Electrical and Electronics Engineers Inc.
ISBN (электронное издание)9781509010806
DOI
СостояниеОпубликовано - 31 июл 2017
Событие2017 International Siberian Conference on Control and Communications, SIBCON 2017 - Astana, Казахстан
Продолжительность: 29 июн 201730 июн 2017

Конференция

Конференция2017 International Siberian Conference on Control and Communications, SIBCON 2017
СтранаКазахстан
ГородAstana
Период29.6.1730.6.17

Отпечаток

Hoists
Permanent Magnet Synchronous Motor
Elevators
Synchronous motors
Rotor
Permanent magnets
Rotors
Rotors (windings)
Leakage Current
Electric drives
Permanent Magnet
Leakage currents
Stators
Simplicity
Voltage
Industry
Angle
Engineers
Sensor
Sensors

ASJC Scopus subject areas

  • Computer Networks and Communications
  • Energy Engineering and Power Technology
  • Control and Optimization
  • Electrical and Electronic Engineering
  • Mechanical Engineering

Цитировать

Krasnov, I. Y., Langraf, S. V., Odnokopylov, I. G., Krokhta, Y. V., Natalinova, N. M., Galtseva, O. V., & Rogachev, A. A. (2017). Sensorless determination of initial position of the rotor of permanent-magnet synchronous motor of the gearless elevator hoist. В 2017 International Siberian Conference on Control and Communications, SIBCON 2017 - Proceedings [7998503] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/SIBCON.2017.7998503

Sensorless determination of initial position of the rotor of permanent-magnet synchronous motor of the gearless elevator hoist. / Krasnov, I. Yu; Langraf, S. V.; Odnokopylov, I. G.; Krokhta, Y. V.; Natalinova, N. M.; Galtseva, O. V.; Rogachev, A. A.

2017 International Siberian Conference on Control and Communications, SIBCON 2017 - Proceedings. Institute of Electrical and Electronics Engineers Inc., 2017. 7998503.

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Krasnov, IY, Langraf, SV, Odnokopylov, IG, Krokhta, YV, Natalinova, NM, Galtseva, OV & Rogachev, AA 2017, Sensorless determination of initial position of the rotor of permanent-magnet synchronous motor of the gearless elevator hoist. в 2017 International Siberian Conference on Control and Communications, SIBCON 2017 - Proceedings., 7998503, Institute of Electrical and Electronics Engineers Inc., Astana, Казахстан, 29.6.17. https://doi.org/10.1109/SIBCON.2017.7998503
Krasnov IY, Langraf SV, Odnokopylov IG, Krokhta YV, Natalinova NM, Galtseva OV и соавт. Sensorless determination of initial position of the rotor of permanent-magnet synchronous motor of the gearless elevator hoist. В 2017 International Siberian Conference on Control and Communications, SIBCON 2017 - Proceedings. Institute of Electrical and Electronics Engineers Inc. 2017. 7998503 https://doi.org/10.1109/SIBCON.2017.7998503
Krasnov, I. Yu ; Langraf, S. V. ; Odnokopylov, I. G. ; Krokhta, Y. V. ; Natalinova, N. M. ; Galtseva, O. V. ; Rogachev, A. A. / Sensorless determination of initial position of the rotor of permanent-magnet synchronous motor of the gearless elevator hoist. 2017 International Siberian Conference on Control and Communications, SIBCON 2017 - Proceedings. Institute of Electrical and Electronics Engineers Inc., 2017.
@inproceedings{68d18392b20f49c88ba13d900895f2db,
title = "Sensorless determination of initial position of the rotor of permanent-magnet synchronous motor of the gearless elevator hoist",
abstract = "Currently the special algorithms are used to determinate an initial position of rotor angle of the permanent magnet synchronous drives. This is especially important for providing of smooth load at the electric drive starting, for example, for gearless elevator hoist drive. For this the position sensors are used in simple electrical drives, but system cost is increased. Paper describes a developed new algorithm, which determines an absolute angular position of rotor of the permanent magnet synchronous motor. Stator is magnetized by leakage currents of windings at applying the specific voltage pulses to the motor. This algorithm allows calculating absolute position of the rotor in practice. The main advantage of presented algorithm is a functioning without motor parameters. Simplicity and algorithm efficiency are confirmed by obtained experiment results by simulation for determination of initial position of rotor of the permanent magnet synchronous motor. Therefore, this method can be widely used by engineers of electrical industry.",
keywords = "Experiments, gearless elevator hoist, initial position determination, permanent magnet synchronous motor, simulation",
author = "Krasnov, {I. Yu} and Langraf, {S. V.} and Odnokopylov, {I. G.} and Krokhta, {Y. V.} and Natalinova, {N. M.} and Galtseva, {O. V.} and Rogachev, {A. A.}",
year = "2017",
month = "7",
day = "31",
doi = "10.1109/SIBCON.2017.7998503",
language = "English",
booktitle = "2017 International Siberian Conference on Control and Communications, SIBCON 2017 - Proceedings",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
address = "United States",

}

TY - GEN

T1 - Sensorless determination of initial position of the rotor of permanent-magnet synchronous motor of the gearless elevator hoist

AU - Krasnov, I. Yu

AU - Langraf, S. V.

AU - Odnokopylov, I. G.

AU - Krokhta, Y. V.

AU - Natalinova, N. M.

AU - Galtseva, O. V.

AU - Rogachev, A. A.

PY - 2017/7/31

Y1 - 2017/7/31

N2 - Currently the special algorithms are used to determinate an initial position of rotor angle of the permanent magnet synchronous drives. This is especially important for providing of smooth load at the electric drive starting, for example, for gearless elevator hoist drive. For this the position sensors are used in simple electrical drives, but system cost is increased. Paper describes a developed new algorithm, which determines an absolute angular position of rotor of the permanent magnet synchronous motor. Stator is magnetized by leakage currents of windings at applying the specific voltage pulses to the motor. This algorithm allows calculating absolute position of the rotor in practice. The main advantage of presented algorithm is a functioning without motor parameters. Simplicity and algorithm efficiency are confirmed by obtained experiment results by simulation for determination of initial position of rotor of the permanent magnet synchronous motor. Therefore, this method can be widely used by engineers of electrical industry.

AB - Currently the special algorithms are used to determinate an initial position of rotor angle of the permanent magnet synchronous drives. This is especially important for providing of smooth load at the electric drive starting, for example, for gearless elevator hoist drive. For this the position sensors are used in simple electrical drives, but system cost is increased. Paper describes a developed new algorithm, which determines an absolute angular position of rotor of the permanent magnet synchronous motor. Stator is magnetized by leakage currents of windings at applying the specific voltage pulses to the motor. This algorithm allows calculating absolute position of the rotor in practice. The main advantage of presented algorithm is a functioning without motor parameters. Simplicity and algorithm efficiency are confirmed by obtained experiment results by simulation for determination of initial position of rotor of the permanent magnet synchronous motor. Therefore, this method can be widely used by engineers of electrical industry.

KW - Experiments

KW - gearless elevator hoist

KW - initial position determination

KW - permanent magnet synchronous motor

KW - simulation

UR - http://www.scopus.com/inward/record.url?scp=85028512410&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85028512410&partnerID=8YFLogxK

U2 - 10.1109/SIBCON.2017.7998503

DO - 10.1109/SIBCON.2017.7998503

M3 - Conference contribution

AN - SCOPUS:85028512410

BT - 2017 International Siberian Conference on Control and Communications, SIBCON 2017 - Proceedings

PB - Institute of Electrical and Electronics Engineers Inc.

ER -