Selecting main technical specifications of the data aquisition system to improve the accuracy of using the electric response parameters

Результат исследований: Материалы для журналарецензирование

Аннотация

Based on the conducted experimental studies, the necessary parameters were selected to provide reliable testing of concrete defects. The measuring system must have: input sensitivity of the receiving electromagnetic channel of at least100 µV, the working frequency range of 1-120 kHz; the sampling frequency of 500 kHz, as well as a device that allows fast Fourier transform. The registration of the electrical response during an elastic impact should be made by a differential electric sensor, which allows measurements under conditions of external electromagnetic interference.

Язык оригиналаАнглийский
Номер статьи012024
ЖурналJournal of Physics: Conference Series
Том1636
Номер выпуска1
DOI
СостояниеОпубликовано - 9 окт 2020
Событие22nd Russian National Conference on Non-Destructive Testing and Technical Diagnostics: Transformation of Non-Destructive Testing and Technical Diagnostics in the Era of Digitalization. Society Security in a Changing World, RNCNDTTD 2020 - Moscow, Российская Федерация
Продолжительность: 3 мар 20205 мар 2020

ASJC Scopus subject areas