Sandwiched gold/PNIPAm/gold microstructures for smart plasmonics application: Towards the high detection limit and Raman quantitative measurements

R. Elashnikov, D. Mares, T. Podzimek, V. Švorčík, O. Lyutakov

Результат исследований: Материалы для журналаСтатья

9 Цитирования (Scopus)

Выдержка

A smart plasmonic sensor, comprising a layer of a stimuli-responsive polymer sandwiched between two gold layers, is reported.As a stimuli-responsive material, a monolayer of poly(N-isopropylacrylamide) (PNIPAm) crosslinked globules is used.A quasi-periodic structure of the top gold layer facilitates efficient excitation and serves as a support for plasmon excitation and propagation.The intermediate layer of PNIPAm efficiently entraps targeted molecules from solutions.The sensor structure was optimized for efficient light focusing in the "active" PNIPAm layer.The optimization was based on the time-resolved finite-element simulations, which take into account the thickness of gold layers, size of PNIPAm globules and Raman excitation wavelength (780 nm).The prepared structures were characterized using SEM, AFM, UV-Vis refractometry and goniometry.Additional AFM scans were performed in water at two temperatures corresponding to the collapsed and swollen PNIPAm states.The Raman measurements demonstrate a high detection limit and perfect reproducibility of the Raman scattering signal for the prepared sensor.In addition, the use of created SERS structures for the detection of relevant molecules in the medical, biological and safety fields was demonstrated.

Язык оригиналаАнглийский
Страницы (с-по)2974-2981
Число страниц8
ЖурналAnalyst
Том142
Номер выпуска16
DOI
СостояниеОпубликовано - 21 авг 2017
Опубликовано для внешнего пользованияДа

Отпечаток

Gold
Limit of Detection
microstructure
gold
Microstructure
Smart sensors
Molecules
Periodic structures
Sensors
sensor
Raman scattering
Monolayers
Refractometry
Raman Spectrum Analysis
Wavelength
Scanning electron microscopy
Polymers
poly-N-isopropylacrylamide
detection
Water

ASJC Scopus subject areas

  • Analytical Chemistry
  • Biochemistry
  • Environmental Chemistry
  • Spectroscopy
  • Electrochemistry

Цитировать

Sandwiched gold/PNIPAm/gold microstructures for smart plasmonics application : Towards the high detection limit and Raman quantitative measurements. / Elashnikov, R.; Mares, D.; Podzimek, T.; Švorčík, V.; Lyutakov, O.

В: Analyst, Том 142, № 16, 21.08.2017, стр. 2974-2981.

Результат исследований: Материалы для журналаСтатья

Elashnikov, R. ; Mares, D. ; Podzimek, T. ; Švorčík, V. ; Lyutakov, O. / Sandwiched gold/PNIPAm/gold microstructures for smart plasmonics application : Towards the high detection limit and Raman quantitative measurements. В: Analyst. 2017 ; Том 142, № 16. стр. 2974-2981.
@article{f2606586a76d429eb8b6fc9b97264bfe,
title = "Sandwiched gold/PNIPAm/gold microstructures for smart plasmonics application: Towards the high detection limit and Raman quantitative measurements",
abstract = "A smart plasmonic sensor, comprising a layer of a stimuli-responsive polymer sandwiched between two gold layers, is reported.As a stimuli-responsive material, a monolayer of poly(N-isopropylacrylamide) (PNIPAm) crosslinked globules is used.A quasi-periodic structure of the top gold layer facilitates efficient excitation and serves as a support for plasmon excitation and propagation.The intermediate layer of PNIPAm efficiently entraps targeted molecules from solutions.The sensor structure was optimized for efficient light focusing in the {"}active{"} PNIPAm layer.The optimization was based on the time-resolved finite-element simulations, which take into account the thickness of gold layers, size of PNIPAm globules and Raman excitation wavelength (780 nm).The prepared structures were characterized using SEM, AFM, UV-Vis refractometry and goniometry.Additional AFM scans were performed in water at two temperatures corresponding to the collapsed and swollen PNIPAm states.The Raman measurements demonstrate a high detection limit and perfect reproducibility of the Raman scattering signal for the prepared sensor.In addition, the use of created SERS structures for the detection of relevant molecules in the medical, biological and safety fields was demonstrated.",
author = "R. Elashnikov and D. Mares and T. Podzimek and V. Švorč{\'i}k and O. Lyutakov",
year = "2017",
month = "8",
day = "21",
doi = "10.1039/c7an00419b",
language = "English",
volume = "142",
pages = "2974--2981",
journal = "The Analyst",
issn = "0003-2654",
publisher = "Royal Society of Chemistry",
number = "16",

}

TY - JOUR

T1 - Sandwiched gold/PNIPAm/gold microstructures for smart plasmonics application

T2 - Towards the high detection limit and Raman quantitative measurements

AU - Elashnikov, R.

AU - Mares, D.

AU - Podzimek, T.

AU - Švorčík, V.

AU - Lyutakov, O.

PY - 2017/8/21

Y1 - 2017/8/21

N2 - A smart plasmonic sensor, comprising a layer of a stimuli-responsive polymer sandwiched between two gold layers, is reported.As a stimuli-responsive material, a monolayer of poly(N-isopropylacrylamide) (PNIPAm) crosslinked globules is used.A quasi-periodic structure of the top gold layer facilitates efficient excitation and serves as a support for plasmon excitation and propagation.The intermediate layer of PNIPAm efficiently entraps targeted molecules from solutions.The sensor structure was optimized for efficient light focusing in the "active" PNIPAm layer.The optimization was based on the time-resolved finite-element simulations, which take into account the thickness of gold layers, size of PNIPAm globules and Raman excitation wavelength (780 nm).The prepared structures were characterized using SEM, AFM, UV-Vis refractometry and goniometry.Additional AFM scans were performed in water at two temperatures corresponding to the collapsed and swollen PNIPAm states.The Raman measurements demonstrate a high detection limit and perfect reproducibility of the Raman scattering signal for the prepared sensor.In addition, the use of created SERS structures for the detection of relevant molecules in the medical, biological and safety fields was demonstrated.

AB - A smart plasmonic sensor, comprising a layer of a stimuli-responsive polymer sandwiched between two gold layers, is reported.As a stimuli-responsive material, a monolayer of poly(N-isopropylacrylamide) (PNIPAm) crosslinked globules is used.A quasi-periodic structure of the top gold layer facilitates efficient excitation and serves as a support for plasmon excitation and propagation.The intermediate layer of PNIPAm efficiently entraps targeted molecules from solutions.The sensor structure was optimized for efficient light focusing in the "active" PNIPAm layer.The optimization was based on the time-resolved finite-element simulations, which take into account the thickness of gold layers, size of PNIPAm globules and Raman excitation wavelength (780 nm).The prepared structures were characterized using SEM, AFM, UV-Vis refractometry and goniometry.Additional AFM scans were performed in water at two temperatures corresponding to the collapsed and swollen PNIPAm states.The Raman measurements demonstrate a high detection limit and perfect reproducibility of the Raman scattering signal for the prepared sensor.In addition, the use of created SERS structures for the detection of relevant molecules in the medical, biological and safety fields was demonstrated.

UR - http://www.scopus.com/inward/record.url?scp=85027049446&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85027049446&partnerID=8YFLogxK

U2 - 10.1039/c7an00419b

DO - 10.1039/c7an00419b

M3 - Article

AN - SCOPUS:85027049446

VL - 142

SP - 2974

EP - 2981

JO - The Analyst

JF - The Analyst

SN - 0003-2654

IS - 16