Radio isotope method for rapid determination of proppant concentration in working mixtures used in hydraulic fracturing of oil and gas containing strata

O. T. Nurgaliev, V. K. Kuleshov, Yu A. Volchenko, M. S. Sukhanov

    Результат исследований: Материалы для журналаСтатья

    Аннотация

    A radio isotope method for rapid determination of proppant concentration and a test measurement unit RIKP-01 constructed on the basis of it provides a relative error in determining proppant concentration of not more than ± 3.5% with a measurement time of 15 sec that is four times better than for the world leader, i.e., the firm Halliburton (USA).

    Язык оригиналаАнглийский
    Страницы (с-по)307-310
    Число страниц4
    ЖурналMeasurement Techniques
    Том48
    Номер выпуска3
    DOI
    СостояниеОпубликовано - мар 2005