    In this report we present state of work under development of LTD stages with air insulation in a primary circuit and vacuum insulation in a secondary turn. Special unit, named capacitor block, was developed for use as a main structural element of the transformer stages. It incorporates two capacitors GA 35426 (40 nF, 100 kV) and multichannel multigap gas switch. Two types of stages were developed: 1) Stage LTD-20 with 4 modules in parallel and 5 capacitor blocks in each module. In tests of this stage current amplitude up to 850 kA with ∼ 140 ns rise time was obtained on a 0.05 Ω load at 100 kV charging voltage. 2) Stage LTD-4 with 2 modules in parallel and 2 capacitor blocks in each module. Several installations were built on base of these stages, including linear transformer, consisting of two identical LTD-20 stages in series, and high power electron accelerator on base of LTD-4 stages. Design of installations and tests results are presented and discussed in this report.

    Язык оригиналаАнглийский
    Название основной публикацииProceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV
    Страницы425-428
    Число страниц4
    DOI
    СостояниеОпубликовано - 2012
    Событие25th International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV 2012 - Tomsk, Российская Федерация
    Продолжительность: 2 сен 20127 сен 2012

    Другое

    Другое25th International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV 2012
    СтранаРоссийская Федерация
    ГородTomsk
    Период2.9.127.9.12

    Отпечаток

    Insulation
    Capacitors
    Vacuum
    Particle accelerators
    Switches
    Networks (circuits)
    Electric potential
    Air
    Gases

    ASJC Scopus subject areas

    • Computer Networks and Communications
    • Software

    Цитировать

    Kharlov, A. V., Kovalchuk, B. M., Kumpyak, E. V., & Zherlitsyn, A. A. (2012). Pulsed generators on base of LTD stages with vacuum insulation in a secondary turn. В Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV (стр. 425-428). [6412546] https://doi.org/10.1109/DEIV.2012.6412546

    Pulsed generators on base of LTD stages with vacuum insulation in a secondary turn. / Kharlov, A. V.; Kovalchuk, B. M.; Kumpyak, E. V.; Zherlitsyn, A. A.

    Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV. 2012. стр. 425-428 6412546.

    Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

    Kharlov, AV, Kovalchuk, BM, Kumpyak, EV & Zherlitsyn, AA 2012, Pulsed generators on base of LTD stages with vacuum insulation in a secondary turn. в Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV., 6412546, стр. 425-428, Tomsk, Российская Федерация, 2.9.12. https://doi.org/10.1109/DEIV.2012.6412546
    Kharlov AV, Kovalchuk BM, Kumpyak EV, Zherlitsyn AA. Pulsed generators on base of LTD stages with vacuum insulation in a secondary turn. В Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV. 2012. стр. 425-428. 6412546 https://doi.org/10.1109/DEIV.2012.6412546
    Kharlov, A. V. ; Kovalchuk, B. M. ; Kumpyak, E. V. ; Zherlitsyn, A. A. / Pulsed generators on base of LTD stages with vacuum insulation in a secondary turn. Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV. 2012. стр. 425-428
    @inproceedings{81ee124f66f44f5997a594eab5322568,
    title = "Pulsed generators on base of LTD stages with vacuum insulation in a secondary turn",
    abstract = "In this report we present state of work under development of LTD stages with air insulation in a primary circuit and vacuum insulation in a secondary turn. Special unit, named capacitor block, was developed for use as a main structural element of the transformer stages. It incorporates two capacitors GA 35426 (40 nF, 100 kV) and multichannel multigap gas switch. Two types of stages were developed: 1) Stage LTD-20 with 4 modules in parallel and 5 capacitor blocks in each module. In tests of this stage current amplitude up to 850 kA with ∼ 140 ns rise time was obtained on a 0.05 Ω load at 100 kV charging voltage. 2) Stage LTD-4 with 2 modules in parallel and 2 capacitor blocks in each module. Several installations were built on base of these stages, including linear transformer, consisting of two identical LTD-20 stages in series, and high power electron accelerator on base of LTD-4 stages. Design of installations and tests results are presented and discussed in this report.",
    author = "Kharlov, {A. V.} and Kovalchuk, {B. M.} and Kumpyak, {E. V.} and Zherlitsyn, {A. A.}",
    year = "2012",
    doi = "10.1109/DEIV.2012.6412546",
    language = "English",
    isbn = "9781467312660",
    pages = "425--428",
    booktitle = "Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV",

    }

    TY - GEN

    T1 - Pulsed generators on base of LTD stages with vacuum insulation in a secondary turn

    AU - Kharlov, A. V.

    AU - Kovalchuk, B. M.

    AU - Kumpyak, E. V.

    AU - Zherlitsyn, A. A.

    PY - 2012

    Y1 - 2012

    N2 - In this report we present state of work under development of LTD stages with air insulation in a primary circuit and vacuum insulation in a secondary turn. Special unit, named capacitor block, was developed for use as a main structural element of the transformer stages. It incorporates two capacitors GA 35426 (40 nF, 100 kV) and multichannel multigap gas switch. Two types of stages were developed: 1) Stage LTD-20 with 4 modules in parallel and 5 capacitor blocks in each module. In tests of this stage current amplitude up to 850 kA with ∼ 140 ns rise time was obtained on a 0.05 Ω load at 100 kV charging voltage. 2) Stage LTD-4 with 2 modules in parallel and 2 capacitor blocks in each module. Several installations were built on base of these stages, including linear transformer, consisting of two identical LTD-20 stages in series, and high power electron accelerator on base of LTD-4 stages. Design of installations and tests results are presented and discussed in this report.

    AB - In this report we present state of work under development of LTD stages with air insulation in a primary circuit and vacuum insulation in a secondary turn. Special unit, named capacitor block, was developed for use as a main structural element of the transformer stages. It incorporates two capacitors GA 35426 (40 nF, 100 kV) and multichannel multigap gas switch. Two types of stages were developed: 1) Stage LTD-20 with 4 modules in parallel and 5 capacitor blocks in each module. In tests of this stage current amplitude up to 850 kA with ∼ 140 ns rise time was obtained on a 0.05 Ω load at 100 kV charging voltage. 2) Stage LTD-4 with 2 modules in parallel and 2 capacitor blocks in each module. Several installations were built on base of these stages, including linear transformer, consisting of two identical LTD-20 stages in series, and high power electron accelerator on base of LTD-4 stages. Design of installations and tests results are presented and discussed in this report.

    UR - http://www.scopus.com/inward/record.url?scp=84873980573&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84873980573&partnerID=8YFLogxK

    U2 - 10.1109/DEIV.2012.6412546

    DO - 10.1109/DEIV.2012.6412546

    M3 - Conference contribution

    AN - SCOPUS:84873980573

    SN - 9781467312660

    SP - 425

    EP - 428

    BT - Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV

    ER -