Prebreakdown phenomena in insulating gas mixtures under very fast transients

W. Pfeiffer, N. Kuzishin, M. Zhurkov

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

1 цитирование (Scopus)

Выдержка

For further improvement of the insulation for high voltage gas insulated transmission lines an alternative gaseous medium is needed in order to substitute completely or at least partially the expensive gas SF 6. This aspect is also important with respect to environmental considerations (greenhouse effect). As a possible alternative to pure SF 6 or SF 6/N 2 (10 % / 90 %) gas mixture, SF 6/CO 2 (10 % / 90 %) gas mixture was chosen [1]. Prebreakdown phenomena under very fast transient voltage stress in the gas mixture were investigated for inhomogeneous field distribution. The following parameters were considered: Pressure range from 0.1 to 0.8 MPa, electric field utilisation factor of the electrode configuration 2.5 %, peak voltage applied up to 160 kV. Both electrical and optical investigation methods were used in the present work.

Язык оригиналаАнглийский
Название основной публикацииConference Record of IEEE International Symposium on Electrical Insulation
Страницы488-491
Число страниц4
DOI
СостояниеОпубликовано - 2008
Событие2008 IEEE International Symposium on Electrical Insulation, ISEI 2008 - Vancouver, BC, Канада
Продолжительность: 9 июн 200812 июн 2008

Другое

Другое2008 IEEE International Symposium on Electrical Insulation, ISEI 2008
СтранаКанада
ГородVancouver, BC
Период9.6.0812.6.08

Отпечаток

Gas mixtures
Electric potential
Greenhouse effect
Gases
Insulation
Electric lines
Electric fields
Electrodes

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Building and Construction

Цитировать

Pfeiffer, W., Kuzishin, N., & Zhurkov, M. (2008). Prebreakdown phenomena in insulating gas mixtures under very fast transients. В Conference Record of IEEE International Symposium on Electrical Insulation (стр. 488-491). [4570379] https://doi.org/10.1109/ELINSL.2008.4570379

Prebreakdown phenomena in insulating gas mixtures under very fast transients. / Pfeiffer, W.; Kuzishin, N.; Zhurkov, M.

Conference Record of IEEE International Symposium on Electrical Insulation. 2008. стр. 488-491 4570379.

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Pfeiffer, W, Kuzishin, N & Zhurkov, M 2008, Prebreakdown phenomena in insulating gas mixtures under very fast transients. в Conference Record of IEEE International Symposium on Electrical Insulation., 4570379, стр. 488-491, 2008 IEEE International Symposium on Electrical Insulation, ISEI 2008, Vancouver, BC, Канада, 9.6.08. https://doi.org/10.1109/ELINSL.2008.4570379
Pfeiffer W, Kuzishin N, Zhurkov M. Prebreakdown phenomena in insulating gas mixtures under very fast transients. В Conference Record of IEEE International Symposium on Electrical Insulation. 2008. стр. 488-491. 4570379 https://doi.org/10.1109/ELINSL.2008.4570379
Pfeiffer, W. ; Kuzishin, N. ; Zhurkov, M. / Prebreakdown phenomena in insulating gas mixtures under very fast transients. Conference Record of IEEE International Symposium on Electrical Insulation. 2008. стр. 488-491
@inproceedings{90cd7cdbf8cf4ee1b428590145033912,
title = "Prebreakdown phenomena in insulating gas mixtures under very fast transients",
abstract = "For further improvement of the insulation for high voltage gas insulated transmission lines an alternative gaseous medium is needed in order to substitute completely or at least partially the expensive gas SF 6. This aspect is also important with respect to environmental considerations (greenhouse effect). As a possible alternative to pure SF 6 or SF 6/N 2 (10 {\%} / 90 {\%}) gas mixture, SF 6/CO 2 (10 {\%} / 90 {\%}) gas mixture was chosen [1]. Prebreakdown phenomena under very fast transient voltage stress in the gas mixture were investigated for inhomogeneous field distribution. The following parameters were considered: Pressure range from 0.1 to 0.8 MPa, electric field utilisation factor of the electrode configuration 2.5 {\%}, peak voltage applied up to 160 kV. Both electrical and optical investigation methods were used in the present work.",
author = "W. Pfeiffer and N. Kuzishin and M. Zhurkov",
year = "2008",
doi = "10.1109/ELINSL.2008.4570379",
language = "English",
pages = "488--491",
booktitle = "Conference Record of IEEE International Symposium on Electrical Insulation",

}

TY - GEN

T1 - Prebreakdown phenomena in insulating gas mixtures under very fast transients

AU - Pfeiffer, W.

AU - Kuzishin, N.

AU - Zhurkov, M.

PY - 2008

Y1 - 2008

N2 - For further improvement of the insulation for high voltage gas insulated transmission lines an alternative gaseous medium is needed in order to substitute completely or at least partially the expensive gas SF 6. This aspect is also important with respect to environmental considerations (greenhouse effect). As a possible alternative to pure SF 6 or SF 6/N 2 (10 % / 90 %) gas mixture, SF 6/CO 2 (10 % / 90 %) gas mixture was chosen [1]. Prebreakdown phenomena under very fast transient voltage stress in the gas mixture were investigated for inhomogeneous field distribution. The following parameters were considered: Pressure range from 0.1 to 0.8 MPa, electric field utilisation factor of the electrode configuration 2.5 %, peak voltage applied up to 160 kV. Both electrical and optical investigation methods were used in the present work.

AB - For further improvement of the insulation for high voltage gas insulated transmission lines an alternative gaseous medium is needed in order to substitute completely or at least partially the expensive gas SF 6. This aspect is also important with respect to environmental considerations (greenhouse effect). As a possible alternative to pure SF 6 or SF 6/N 2 (10 % / 90 %) gas mixture, SF 6/CO 2 (10 % / 90 %) gas mixture was chosen [1]. Prebreakdown phenomena under very fast transient voltage stress in the gas mixture were investigated for inhomogeneous field distribution. The following parameters were considered: Pressure range from 0.1 to 0.8 MPa, electric field utilisation factor of the electrode configuration 2.5 %, peak voltage applied up to 160 kV. Both electrical and optical investigation methods were used in the present work.

UR - http://www.scopus.com/inward/record.url?scp=52049090553&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=52049090553&partnerID=8YFLogxK

U2 - 10.1109/ELINSL.2008.4570379

DO - 10.1109/ELINSL.2008.4570379

M3 - Conference contribution

AN - SCOPUS:52049090553

SP - 488

EP - 491

BT - Conference Record of IEEE International Symposium on Electrical Insulation

ER -