Performance of Multiplexed XY Resistive Micromegas detectors in a high intensity beam

D. Banerjee, V. Burtsev, A. Chumakov, D. Cooke, E. Depero, A. V. Dermenev, S. V. Donskov, F. Dubinin, R. R. Dusaev, S. Emmenegger, A. Fabich, V. N. Frolov, A. Gardikiotis, S. N. Gninenko, M. Hösgen, A. E. Karneyeu, B. Ketzer, M. M. Kirsanov, I. V. Konorov, V. A. KramarenkoS. V. Kuleshov, E. Levchenko, V. E. Lyubovitskij, V. Lysan, S. Mamon, V. A. Matveev, Yu V. Mikhailov, V. V. Myalkovskiy, D. V. Peshekhonov, D. V. Peshekhonov, V. A. Polyakov, B. Radics, A. Rubbia, V. D. Samoylenko, V. O. Tikhomirov, D. A. Tlisov, A. N. Toropin, B. Vasilishin, G. Vasquez Arenas, P. Ulloa, P. Crivelli, Sergey Alexandrovich Mamon

Результат исследований: Материалы для журналаСтатья

3 Цитирования (Scopus)

Аннотация

We present the performance of multiplexed XY resistive Micromegas detectors tested in the CERN SPS 100 GeV/c electron beam at intensities up to 3.3×105e∕(s⋅cm2). So far, all studies with multiplexed Micromegas have only been reported for tests with radioactive sources and cosmic rays. The use of multiplexed modules in high intensity environments was not explored due to the effect of ambiguities in the reconstruction of the hit point caused by the multiplexing feature. For the specific mapping and beam intensities analyzed in this work with a multiplexing factor of five, more than 50% level of ambiguity is introduced due to particle pile-up as well as fake clusters due to the mapping feature. Our results prove that by using the additional information of cluster size and integrated charge from the signal clusters induced on the XY strips, the ambiguities can be reduced to a level below 2%. The tested detectors are used in the CERN NA64 experiment for tracking the incoming particles bending in a magnetic field in order to reconstruct their momentum. The average hit detection efficiency of each module was found to be ∼96% at the highest beam intensities. By using four modules a tracking resolution of 1.1% was obtained with ∼85% combined tracking efficiency.

Язык оригиналаАнглийский
Страницы (с-по)72-81
Число страниц10
ЖурналNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Том881
DOI
СостояниеОпубликовано - 11 фев 2018

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Fingerprint Подробные сведения о темах исследования «Performance of Multiplexed XY Resistive Micromegas detectors in a high intensity beam». Вместе они формируют уникальный семантический отпечаток (fingerprint).

  • Цитировать

    Banerjee, D., Burtsev, V., Chumakov, A., Cooke, D., Depero, E., Dermenev, A. V., Donskov, S. V., Dubinin, F., Dusaev, R. R., Emmenegger, S., Fabich, A., Frolov, V. N., Gardikiotis, A., Gninenko, S. N., Hösgen, M., Karneyeu, A. E., Ketzer, B., Kirsanov, M. M., Konorov, I. V., ... Mamon, S. A. (2018). Performance of Multiplexed XY Resistive Micromegas detectors in a high intensity beam. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 881, 72-81. https://doi.org/10.1016/j.nima.2017.10.067