Peculiarities of pumping of copper vapour and copper bromide vapour lasers

G. S. Evtushenko, I. D. Kostyrya, V. B. Sukhanov, V. F. Tarasenko, D. V. Shiyanov

Результат исследований: Материалы для журналаСтатья

2 Цитирования (Scopus)

Аннотация

Lasing and peculiarities of pumping of a copper vapour laser with a commercially produced 'Crystal' LT-40Cu active element and of a CuBr laser with a large-volume experimental active element are studied experimentally. It is shown that the efficiency of lasers with an average radiation power up to 50 W relative to the energy supplied to the active medium during useful pumping achieves 4%. It is found that the stage of useful pumping of the central part of the laser tube is preceded by a partial breakdown of the discharge gap and the charging of parasitic capacitances. A distinguishing feature of the pumping of a CuBr laser as compared to the Cu laser is that the inductance of the leads from the pump oscillator to the active element and the inductance of the pump oscillator can be increased, while the average radiation power remains unchanged.

Язык оригиналаАнглийский
Страницы (с-по)704-708
Число страниц5
ЖурналQuantum Electronics
Том31
Номер выпуска8
DOI
СостояниеОпубликовано - авг 2001

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Physics and Astronomy (miscellaneous)

Fingerprint Подробные сведения о темах исследования «Peculiarities of pumping of copper vapour and copper bromide vapour lasers». Вместе они формируют уникальный семантический отпечаток (fingerprint).