Parametric X-rays generated by electrons in multilayer mirrors mounted inside a betatron

V. V. Kaplin, S. R. Uglov, V. V. Sohoreva, O. F. Bulaev, A. A. Voronin, M. Piestrup, C. Gary, M. Fuller

Результат исследований: Материалы для журналаСтатья

19 Цитирования (Scopus)

Выдержка

The measured characteristics of tunable, quasi-monochromatic X-rays from thin multilayer mirrors used as radiators mounted inside a 35 MeV betatron chamber are presented. Parametric X-ray radiation (PXR) was generated by 15-33 MeV electrons passing through two radiators consisted of a few hundreds of W/B4C bilayers with period of 14.86 and 18 A. Shifts of the PXR spectra were measured as the orientation of the multilayer radiators relative to the incident electron beam was changed. The PXR flux was determined by comparison with the yield of L fluorescence generated by electrons in the W layers of the multilayer.

Язык оригиналаАнглийский
Страницы (с-по)777-780
Число страниц4
ЖурналNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
Том267
Номер выпуска5
DOI
СостояниеОпубликовано - 1 мар 2009

Отпечаток

Betatrons
betatrons
Multilayers
Radiators
radiators
mirrors
X rays
Electrons
Radiation
electrons
x rays
radiation spectra
radiation
Electron beams
chambers
Fluorescence
electron beams
Fluxes
fluorescence
shift

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Цитировать

Parametric X-rays generated by electrons in multilayer mirrors mounted inside a betatron. / Kaplin, V. V.; Uglov, S. R.; Sohoreva, V. V.; Bulaev, O. F.; Voronin, A. A.; Piestrup, M.; Gary, C.; Fuller, M.

В: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, Том 267, № 5, 01.03.2009, стр. 777-780.

Результат исследований: Материалы для журналаСтатья

@article{4be5fbd9a4bc46aa8235fb7f4c5f42b5,
title = "Parametric X-rays generated by electrons in multilayer mirrors mounted inside a betatron",
abstract = "The measured characteristics of tunable, quasi-monochromatic X-rays from thin multilayer mirrors used as radiators mounted inside a 35 MeV betatron chamber are presented. Parametric X-ray radiation (PXR) was generated by 15-33 MeV electrons passing through two radiators consisted of a few hundreds of W/B4C bilayers with period of 14.86 and 18 A. Shifts of the PXR spectra were measured as the orientation of the multilayer radiators relative to the incident electron beam was changed. The PXR flux was determined by comparison with the yield of L fluorescence generated by electrons in the W layers of the multilayer.",
keywords = "Parametric X-rays, Periodic nanostructure, X-ray mirror",
author = "Kaplin, {V. V.} and Uglov, {S. R.} and Sohoreva, {V. V.} and Bulaev, {O. F.} and Voronin, {A. A.} and M. Piestrup and C. Gary and M. Fuller",
year = "2009",
month = "3",
day = "1",
doi = "10.1016/j.nimb.2008.11.014",
language = "English",
volume = "267",
pages = "777--780",
journal = "Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms",
issn = "0168-583X",
publisher = "Elsevier",
number = "5",

}

TY - JOUR

T1 - Parametric X-rays generated by electrons in multilayer mirrors mounted inside a betatron

AU - Kaplin, V. V.

AU - Uglov, S. R.

AU - Sohoreva, V. V.

AU - Bulaev, O. F.

AU - Voronin, A. A.

AU - Piestrup, M.

AU - Gary, C.

AU - Fuller, M.

PY - 2009/3/1

Y1 - 2009/3/1

N2 - The measured characteristics of tunable, quasi-monochromatic X-rays from thin multilayer mirrors used as radiators mounted inside a 35 MeV betatron chamber are presented. Parametric X-ray radiation (PXR) was generated by 15-33 MeV electrons passing through two radiators consisted of a few hundreds of W/B4C bilayers with period of 14.86 and 18 A. Shifts of the PXR spectra were measured as the orientation of the multilayer radiators relative to the incident electron beam was changed. The PXR flux was determined by comparison with the yield of L fluorescence generated by electrons in the W layers of the multilayer.

AB - The measured characteristics of tunable, quasi-monochromatic X-rays from thin multilayer mirrors used as radiators mounted inside a 35 MeV betatron chamber are presented. Parametric X-ray radiation (PXR) was generated by 15-33 MeV electrons passing through two radiators consisted of a few hundreds of W/B4C bilayers with period of 14.86 and 18 A. Shifts of the PXR spectra were measured as the orientation of the multilayer radiators relative to the incident electron beam was changed. The PXR flux was determined by comparison with the yield of L fluorescence generated by electrons in the W layers of the multilayer.

KW - Parametric X-rays

KW - Periodic nanostructure

KW - X-ray mirror

UR - http://www.scopus.com/inward/record.url?scp=61549117182&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=61549117182&partnerID=8YFLogxK

U2 - 10.1016/j.nimb.2008.11.014

DO - 10.1016/j.nimb.2008.11.014

M3 - Article

AN - SCOPUS:61549117182

VL - 267

SP - 777

EP - 780

JO - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

JF - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

SN - 0168-583X

IS - 5

ER -