Operation of triggerable gas diverters on SYRINX/GSI water transmission line

A. A. Kim, B. M. Kovalcbuk, S. N. Volkov, V. A. Sinebryukhov, F. Lassalle, G. Avrillaud

    Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

    Выдержка

    SYRINX/GSI [1] is a 640 kJ installation that has been created at CEG in order to test the advanced pulsed power technologies. Four fast Marxes charge a 110 ns, 0.135 Ohm Water Transmission Line (WTL) in ∼ 700 ns to ∼ 600 kV, downstream the WTL locates the 110 nH vacuum inductive storage, and the POS. During tests in full configuration it was found that the WTL can be damaged due to breakdowns in water as the reversal voltage in WTL exceeds ∼ 350 kV. The report presents the design and the operation of the triggerable gas diverters that were developed at HCEI and installed on SYRINX/GSI to protect the WTL from reversal voltage.

    Язык оригиналаАнглийский
    Название основной публикацииPPPS 2001 - Pulsed Power Plasma Science 2001
    ИздательInstitute of Electrical and Electronics Engineers Inc.
    Страницы1743-1745
    Число страниц3
    Том2
    ISBN (печатное издание)0780371208, 9780780371200
    DOI
    СостояниеОпубликовано - 2001
    Событие28th IEEE International Conference on Plasma Science and 13th IEEE International Pulsed Power Conference, PPPS 2001 - Las Vegas, Соединенные Штаты Америки
    Продолжительность: 17 июн 200122 июн 2001

    Другое

    Другое28th IEEE International Conference on Plasma Science and 13th IEEE International Pulsed Power Conference, PPPS 2001
    СтранаСоединенные Штаты Америки
    ГородLas Vegas
    Период17.6.0122.6.01

    Отпечаток

    diverters
    transmission lines
    Electric lines
    Gases
    gases
    water
    Water
    Electric potential
    electric potential
    installing
    breakdown
    Vacuum
    vacuum

    ASJC Scopus subject areas

    • Energy Engineering and Power Technology
    • Nuclear Energy and Engineering
    • Nuclear and High Energy Physics

    Цитировать

    Kim, A. A., Kovalcbuk, B. M., Volkov, S. N., Sinebryukhov, V. A., Lassalle, F., & Avrillaud, G. (2001). Operation of triggerable gas diverters on SYRINX/GSI water transmission line. В PPPS 2001 - Pulsed Power Plasma Science 2001 (Том 2, стр. 1743-1745). [1001908] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/PPPS.2001.1001908

    Operation of triggerable gas diverters on SYRINX/GSI water transmission line. / Kim, A. A.; Kovalcbuk, B. M.; Volkov, S. N.; Sinebryukhov, V. A.; Lassalle, F.; Avrillaud, G.

    PPPS 2001 - Pulsed Power Plasma Science 2001. Том 2 Institute of Electrical and Electronics Engineers Inc., 2001. стр. 1743-1745 1001908.

    Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

    Kim, AA, Kovalcbuk, BM, Volkov, SN, Sinebryukhov, VA, Lassalle, F & Avrillaud, G 2001, Operation of triggerable gas diverters on SYRINX/GSI water transmission line. в PPPS 2001 - Pulsed Power Plasma Science 2001. том. 2, 1001908, Institute of Electrical and Electronics Engineers Inc., стр. 1743-1745, Las Vegas, Соединенные Штаты Америки, 17.6.01. https://doi.org/10.1109/PPPS.2001.1001908
    Kim AA, Kovalcbuk BM, Volkov SN, Sinebryukhov VA, Lassalle F, Avrillaud G. Operation of triggerable gas diverters on SYRINX/GSI water transmission line. В PPPS 2001 - Pulsed Power Plasma Science 2001. Том 2. Institute of Electrical and Electronics Engineers Inc. 2001. стр. 1743-1745. 1001908 https://doi.org/10.1109/PPPS.2001.1001908
    Kim, A. A. ; Kovalcbuk, B. M. ; Volkov, S. N. ; Sinebryukhov, V. A. ; Lassalle, F. ; Avrillaud, G. / Operation of triggerable gas diverters on SYRINX/GSI water transmission line. PPPS 2001 - Pulsed Power Plasma Science 2001. Том 2 Institute of Electrical and Electronics Engineers Inc., 2001. стр. 1743-1745
    @inproceedings{23de665329e84d90b2c417d10b38e7da,
    title = "Operation of triggerable gas diverters on SYRINX/GSI water transmission line",
    abstract = "SYRINX/GSI [1] is a 640 kJ installation that has been created at CEG in order to test the advanced pulsed power technologies. Four fast Marxes charge a 110 ns, 0.135 Ohm Water Transmission Line (WTL) in ∼ 700 ns to ∼ 600 kV, downstream the WTL locates the 110 nH vacuum inductive storage, and the POS. During tests in full configuration it was found that the WTL can be damaged due to breakdowns in water as the reversal voltage in WTL exceeds ∼ 350 kV. The report presents the design and the operation of the triggerable gas diverters that were developed at HCEI and installed on SYRINX/GSI to protect the WTL from reversal voltage.",
    author = "Kim, {A. A.} and Kovalcbuk, {B. M.} and Volkov, {S. N.} and Sinebryukhov, {V. A.} and F. Lassalle and G. Avrillaud",
    year = "2001",
    doi = "10.1109/PPPS.2001.1001908",
    language = "English",
    isbn = "0780371208",
    volume = "2",
    pages = "1743--1745",
    booktitle = "PPPS 2001 - Pulsed Power Plasma Science 2001",
    publisher = "Institute of Electrical and Electronics Engineers Inc.",

    }

    TY - GEN

    T1 - Operation of triggerable gas diverters on SYRINX/GSI water transmission line

    AU - Kim, A. A.

    AU - Kovalcbuk, B. M.

    AU - Volkov, S. N.

    AU - Sinebryukhov, V. A.

    AU - Lassalle, F.

    AU - Avrillaud, G.

    PY - 2001

    Y1 - 2001

    N2 - SYRINX/GSI [1] is a 640 kJ installation that has been created at CEG in order to test the advanced pulsed power technologies. Four fast Marxes charge a 110 ns, 0.135 Ohm Water Transmission Line (WTL) in ∼ 700 ns to ∼ 600 kV, downstream the WTL locates the 110 nH vacuum inductive storage, and the POS. During tests in full configuration it was found that the WTL can be damaged due to breakdowns in water as the reversal voltage in WTL exceeds ∼ 350 kV. The report presents the design and the operation of the triggerable gas diverters that were developed at HCEI and installed on SYRINX/GSI to protect the WTL from reversal voltage.

    AB - SYRINX/GSI [1] is a 640 kJ installation that has been created at CEG in order to test the advanced pulsed power technologies. Four fast Marxes charge a 110 ns, 0.135 Ohm Water Transmission Line (WTL) in ∼ 700 ns to ∼ 600 kV, downstream the WTL locates the 110 nH vacuum inductive storage, and the POS. During tests in full configuration it was found that the WTL can be damaged due to breakdowns in water as the reversal voltage in WTL exceeds ∼ 350 kV. The report presents the design and the operation of the triggerable gas diverters that were developed at HCEI and installed on SYRINX/GSI to protect the WTL from reversal voltage.

    UR - http://www.scopus.com/inward/record.url?scp=84951980566&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84951980566&partnerID=8YFLogxK

    U2 - 10.1109/PPPS.2001.1001908

    DO - 10.1109/PPPS.2001.1001908

    M3 - Conference contribution

    AN - SCOPUS:84951980566

    SN - 0780371208

    SN - 9780780371200

    VL - 2

    SP - 1743

    EP - 1745

    BT - PPPS 2001 - Pulsed Power Plasma Science 2001

    PB - Institute of Electrical and Electronics Engineers Inc.

    ER -