Monochromatization of high- current nanosecond pulse source of X-ray bremsstrahlung

Y. N. Adischev, K. V. Afanasiev, A. V. Vukolov, A. P. Potylitsyn

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Выдержка

The bremsstrahlung spectrum of the nanosecond electron accelerator on the basis of the vacuum diode supplied by the high-voltage nanosecond generator SINUS - 150 with the coaxial forming line combined with the transformer has been monochromatized by the tungsten crystal under the Bragg - geometry (θB = 45°). The dose field map has been taken by the dosimeter on the basis of the diamond detector in the median acceleration plane. The bremsstrahlung radiation beam divergence has left 62°. It has been shown that the maximum dose is 16 cGrey/s at the distance of 10 cm from the collector, then it falls down proportionally to the square of distance to the level less than 0.1 cGrey/s at the distance of 1 m. The X-Ray spectrum has been measured by the silicon semi-conductor X-ray spectrometer with energy resolution 280 eV for 5.9 keV. It has been shown that the two maximum at the spectrum corresponds the second and third orders of diffraction on (111) planes of a tungsten crystal.

Язык оригиналаАнглийский
Название основной публикацииProceedings of SPIE - The International Society for Optical Engineering
Том6634
DOI
СостояниеОпубликовано - 2007
СобытиеInternational Conference on Charged and Neutral Particles Channeling: Phenomena II - Rome, Италия
Продолжительность: 3 июл 20067 июл 2006

Другое

ДругоеInternational Conference on Charged and Neutral Particles Channeling: Phenomena II
СтранаИталия
ГородRome
Период3.7.067.7.06

Отпечаток

monochromatization
bremsstrahlung
Tungsten
high current
X ray spectrometers
X rays
Crystals
Dosimeters
tungsten
pulses
voltage generators
Dosimetry
Particle accelerators
Diamonds
dosage
Diodes
x rays
electron accelerators
Diffraction
Vacuum

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Condensed Matter Physics

Цитировать

Adischev, Y. N., Afanasiev, K. V., Vukolov, A. V., & Potylitsyn, A. P. (2007). Monochromatization of high- current nanosecond pulse source of X-ray bremsstrahlung. В Proceedings of SPIE - The International Society for Optical Engineering (Том 6634). [663409] https://doi.org/10.1117/12.741842

Monochromatization of high- current nanosecond pulse source of X-ray bremsstrahlung. / Adischev, Y. N.; Afanasiev, K. V.; Vukolov, A. V.; Potylitsyn, A. P.

Proceedings of SPIE - The International Society for Optical Engineering. Том 6634 2007. 663409.

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Adischev, YN, Afanasiev, KV, Vukolov, AV & Potylitsyn, AP 2007, Monochromatization of high- current nanosecond pulse source of X-ray bremsstrahlung. в Proceedings of SPIE - The International Society for Optical Engineering. том. 6634, 663409, Rome, Италия, 3.7.06. https://doi.org/10.1117/12.741842
Adischev YN, Afanasiev KV, Vukolov AV, Potylitsyn AP. Monochromatization of high- current nanosecond pulse source of X-ray bremsstrahlung. В Proceedings of SPIE - The International Society for Optical Engineering. Том 6634. 2007. 663409 https://doi.org/10.1117/12.741842
Adischev, Y. N. ; Afanasiev, K. V. ; Vukolov, A. V. ; Potylitsyn, A. P. / Monochromatization of high- current nanosecond pulse source of X-ray bremsstrahlung. Proceedings of SPIE - The International Society for Optical Engineering. Том 6634 2007.
@inproceedings{9b3c697e6caa4d6391ec57803f381d73,
title = "Monochromatization of high- current nanosecond pulse source of X-ray bremsstrahlung",
abstract = "The bremsstrahlung spectrum of the nanosecond electron accelerator on the basis of the vacuum diode supplied by the high-voltage nanosecond generator SINUS - 150 with the coaxial forming line combined with the transformer has been monochromatized by the tungsten crystal under the Bragg - geometry (θB = 45°). The dose field map has been taken by the dosimeter on the basis of the diamond detector in the median acceleration plane. The bremsstrahlung radiation beam divergence has left 62°. It has been shown that the maximum dose is 16 cGrey/s at the distance of 10 cm from the collector, then it falls down proportionally to the square of distance to the level less than 0.1 cGrey/s at the distance of 1 m. The X-Ray spectrum has been measured by the silicon semi-conductor X-ray spectrometer with energy resolution 280 eV for 5.9 keV. It has been shown that the two maximum at the spectrum corresponds the second and third orders of diffraction on (111) planes of a tungsten crystal.",
keywords = "Bremsstrahlung spectrum, Crystal, Dosimeter, Nanosecond electron accelerator, Spectrometer",
author = "Adischev, {Y. N.} and Afanasiev, {K. V.} and Vukolov, {A. V.} and Potylitsyn, {A. P.}",
year = "2007",
doi = "10.1117/12.741842",
language = "English",
isbn = "0819467782",
volume = "6634",
booktitle = "Proceedings of SPIE - The International Society for Optical Engineering",

}

TY - GEN

T1 - Monochromatization of high- current nanosecond pulse source of X-ray bremsstrahlung

AU - Adischev, Y. N.

AU - Afanasiev, K. V.

AU - Vukolov, A. V.

AU - Potylitsyn, A. P.

PY - 2007

Y1 - 2007

N2 - The bremsstrahlung spectrum of the nanosecond electron accelerator on the basis of the vacuum diode supplied by the high-voltage nanosecond generator SINUS - 150 with the coaxial forming line combined with the transformer has been monochromatized by the tungsten crystal under the Bragg - geometry (θB = 45°). The dose field map has been taken by the dosimeter on the basis of the diamond detector in the median acceleration plane. The bremsstrahlung radiation beam divergence has left 62°. It has been shown that the maximum dose is 16 cGrey/s at the distance of 10 cm from the collector, then it falls down proportionally to the square of distance to the level less than 0.1 cGrey/s at the distance of 1 m. The X-Ray spectrum has been measured by the silicon semi-conductor X-ray spectrometer with energy resolution 280 eV for 5.9 keV. It has been shown that the two maximum at the spectrum corresponds the second and third orders of diffraction on (111) planes of a tungsten crystal.

AB - The bremsstrahlung spectrum of the nanosecond electron accelerator on the basis of the vacuum diode supplied by the high-voltage nanosecond generator SINUS - 150 with the coaxial forming line combined with the transformer has been monochromatized by the tungsten crystal under the Bragg - geometry (θB = 45°). The dose field map has been taken by the dosimeter on the basis of the diamond detector in the median acceleration plane. The bremsstrahlung radiation beam divergence has left 62°. It has been shown that the maximum dose is 16 cGrey/s at the distance of 10 cm from the collector, then it falls down proportionally to the square of distance to the level less than 0.1 cGrey/s at the distance of 1 m. The X-Ray spectrum has been measured by the silicon semi-conductor X-ray spectrometer with energy resolution 280 eV for 5.9 keV. It has been shown that the two maximum at the spectrum corresponds the second and third orders of diffraction on (111) planes of a tungsten crystal.

KW - Bremsstrahlung spectrum

KW - Crystal

KW - Dosimeter

KW - Nanosecond electron accelerator

KW - Spectrometer

UR - http://www.scopus.com/inward/record.url?scp=36249032036&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=36249032036&partnerID=8YFLogxK

U2 - 10.1117/12.741842

DO - 10.1117/12.741842

M3 - Conference contribution

AN - SCOPUS:36249032036

SN - 0819467782

SN - 9780819467782

VL - 6634

BT - Proceedings of SPIE - The International Society for Optical Engineering

ER -