Mikrofluidní Zařízení Pro Průtokovou Injekční Analýzu S Elektrochemickou Detekcí

Alexandr Muck, Joseph Wang, Jiří Barek

Результат исследований: Материалы для журналаСтатьярецензирование

1 Цитирования (Scopus)

Аннотация

The performance of a new microfluidic device was tested in a flow-injection analysis arrangement. The influence of the electric field intensity, sample volume and concentration as well as the repeatability were evaluated for dopamine and p-cresol. Determination of glucose was carried out after reaction with glucose oxidase using amperometric detection at gold-coated screen-printed carbon ink electrode. The method provided reliable performance and easy operation. Millimolar detection limits for glucose and micromolar detection limits for dopamine and p-cresol were achieved.

Переведенное названиеMicrofluidic Platform for FIA with Electrochemical Detection
Язык оригиналаCzech
Страницы (с-по)957-960
Число страниц4
ЖурналChemicke Listy
Том97
Номер выпуска9
СостояниеОпубликовано - 18 ноя 2003
Опубликовано для внешнего пользованияДа

ASJC Scopus subject areas

  • Chemistry(all)

Fingerprint Подробные сведения о темах исследования «Mikrofluidní Zařízení Pro Průtokovou Injekční Analýzu S Elektrochemickou Detekcí». Вместе они формируют уникальный семантический отпечаток (fingerprint).