Longitudinal beam profile monitor at CTF3 based on Coherent Diffraction Radiation

M. Micheler, R. Ainsworth, G. A. Blair, G. Boorman, R. Corsini, P. Karataev, T. Lefevre, K. Lekomtsev

Результат исследований: Материалы для журналаСтатья

2 Цитирования (Scopus)

Выдержка

A setup for the investigation of Coherent Diffraction Radiation (CDR) from a conducting screen as a tool for non-invasive longitudinal electron beam profile diagnostics has been designed and installed in the Combiner Ring Measurement (CRM) line of the CLIC Test Facility (CTF3, CERN). In parallel, the investigation of Coherent Synchrotron Radiation (CSR) generated mostly in the last bending magnet of the combiner ring is foreseen. The first measurements of CDR and CSR are obtained. In this paper we present the status of the experiment and future plans.

Язык оригиналаАнглийский
Номер статьи012021
ЖурналJournal of Physics: Conference Series
Том236
DOI
СостояниеОпубликовано - 2010
Опубликовано для внешнего пользованияДа

Отпечаток

diffraction radiation
monitors
synchrotron radiation
rings
test facilities
profiles
magnets
electron beams
conduction

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Цитировать

Longitudinal beam profile monitor at CTF3 based on Coherent Diffraction Radiation. / Micheler, M.; Ainsworth, R.; Blair, G. A.; Boorman, G.; Corsini, R.; Karataev, P.; Lefevre, T.; Lekomtsev, K.

В: Journal of Physics: Conference Series, Том 236, 012021, 2010.

Результат исследований: Материалы для журналаСтатья

Micheler, M, Ainsworth, R, Blair, GA, Boorman, G, Corsini, R, Karataev, P, Lefevre, T & Lekomtsev, K 2010, 'Longitudinal beam profile monitor at CTF3 based on Coherent Diffraction Radiation', Journal of Physics: Conference Series, том. 236, 012021. https://doi.org/10.1088/1742-6596/236/1/012021
Micheler, M. ; Ainsworth, R. ; Blair, G. A. ; Boorman, G. ; Corsini, R. ; Karataev, P. ; Lefevre, T. ; Lekomtsev, K. / Longitudinal beam profile monitor at CTF3 based on Coherent Diffraction Radiation. В: Journal of Physics: Conference Series. 2010 ; Том 236.
@article{eac50b0e94ff43018f1d1ed6c4d5336f,
title = "Longitudinal beam profile monitor at CTF3 based on Coherent Diffraction Radiation",
abstract = "A setup for the investigation of Coherent Diffraction Radiation (CDR) from a conducting screen as a tool for non-invasive longitudinal electron beam profile diagnostics has been designed and installed in the Combiner Ring Measurement (CRM) line of the CLIC Test Facility (CTF3, CERN). In parallel, the investigation of Coherent Synchrotron Radiation (CSR) generated mostly in the last bending magnet of the combiner ring is foreseen. The first measurements of CDR and CSR are obtained. In this paper we present the status of the experiment and future plans.",
author = "M. Micheler and R. Ainsworth and Blair, {G. A.} and G. Boorman and R. Corsini and P. Karataev and T. Lefevre and K. Lekomtsev",
year = "2010",
doi = "10.1088/1742-6596/236/1/012021",
language = "English",
volume = "236",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",

}

TY - JOUR

T1 - Longitudinal beam profile monitor at CTF3 based on Coherent Diffraction Radiation

AU - Micheler, M.

AU - Ainsworth, R.

AU - Blair, G. A.

AU - Boorman, G.

AU - Corsini, R.

AU - Karataev, P.

AU - Lefevre, T.

AU - Lekomtsev, K.

PY - 2010

Y1 - 2010

N2 - A setup for the investigation of Coherent Diffraction Radiation (CDR) from a conducting screen as a tool for non-invasive longitudinal electron beam profile diagnostics has been designed and installed in the Combiner Ring Measurement (CRM) line of the CLIC Test Facility (CTF3, CERN). In parallel, the investigation of Coherent Synchrotron Radiation (CSR) generated mostly in the last bending magnet of the combiner ring is foreseen. The first measurements of CDR and CSR are obtained. In this paper we present the status of the experiment and future plans.

AB - A setup for the investigation of Coherent Diffraction Radiation (CDR) from a conducting screen as a tool for non-invasive longitudinal electron beam profile diagnostics has been designed and installed in the Combiner Ring Measurement (CRM) line of the CLIC Test Facility (CTF3, CERN). In parallel, the investigation of Coherent Synchrotron Radiation (CSR) generated mostly in the last bending magnet of the combiner ring is foreseen. The first measurements of CDR and CSR are obtained. In this paper we present the status of the experiment and future plans.

UR - http://www.scopus.com/inward/record.url?scp=78651080374&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78651080374&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/236/1/012021

DO - 10.1088/1742-6596/236/1/012021

M3 - Article

AN - SCOPUS:78651080374

VL - 236

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

M1 - 012021

ER -