Investigation of sensitivity of aluminum foil based strain sensors at fatigue damage evaluation of CFRP

M. V. Burkov, S. V. Panin, P. S. Lyubutin, A. V. Eremin

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

3 Цитирования (Scopus)

Выдержка

For the development of a technique for cyclic deformation assessment using aluminum foil sensors glued onto the specimen surface the fatigue tests of carbon fiber reinforced polymer (CFRP) specimens were carried out. The DSLR camera mounted onto an optical microscope was used for capturing the images of sensors to reflect strain induced relief, which than was numerically estimated using various informative parameters in order to obtain the cyclic deformation assessment of composite. The results are discussed in view of application of this method for the development of Structural Health Monitoring (SHM) approach.

Язык оригиналаАнглийский
Название основной публикацииHigh Technology
Подзаголовок основной публикацииResearch and Applications
ИздательTrans Tech Publications Ltd
Страницы943-948
Число страниц6
ISBN (электронное издание)9783038352648
DOI
СостояниеОпубликовано - 1 янв 2014
СобытиеInternational Conference for Young Scientists “High Technology: Research and Applications 2014”, HTRA 2014 - Tomsk, Российская Федерация
Продолжительность: 26 мар 201428 мар 2014

Серия публикаций

НазваниеAdvanced Materials Research
Том1040
ISSN (печатное издание)1022-6680
ISSN (электронное издание)1662-8985

Конференция

КонференцияInternational Conference for Young Scientists “High Technology: Research and Applications 2014”, HTRA 2014
СтранаРоссийская Федерация
ГородTomsk
Период26.3.1428.3.14

Отпечаток

Aluminum foil
Fatigue damage
Carbon fibers
Structural health monitoring
Sensors
Polymers
Microscopes
Cameras
Fatigue of materials
Composite materials

ASJC Scopus subject areas

  • Engineering(all)

Цитировать

Burkov, M. V., Panin, S. V., Lyubutin, P. S., & Eremin, A. V. (2014). Investigation of sensitivity of aluminum foil based strain sensors at fatigue damage evaluation of CFRP. В High Technology: Research and Applications (стр. 943-948). (Advanced Materials Research; Том 1040). Trans Tech Publications Ltd. https://doi.org/10.4028/www.scientific.net/AMR.1040.943

Investigation of sensitivity of aluminum foil based strain sensors at fatigue damage evaluation of CFRP. / Burkov, M. V.; Panin, S. V.; Lyubutin, P. S.; Eremin, A. V.

High Technology: Research and Applications. Trans Tech Publications Ltd, 2014. стр. 943-948 (Advanced Materials Research; Том 1040).

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Burkov, MV, Panin, SV, Lyubutin, PS & Eremin, AV 2014, Investigation of sensitivity of aluminum foil based strain sensors at fatigue damage evaluation of CFRP. в High Technology: Research and Applications. Advanced Materials Research, том. 1040, Trans Tech Publications Ltd, стр. 943-948, Tomsk, Российская Федерация, 26.3.14. https://doi.org/10.4028/www.scientific.net/AMR.1040.943
Burkov MV, Panin SV, Lyubutin PS, Eremin AV. Investigation of sensitivity of aluminum foil based strain sensors at fatigue damage evaluation of CFRP. В High Technology: Research and Applications. Trans Tech Publications Ltd. 2014. стр. 943-948. (Advanced Materials Research). https://doi.org/10.4028/www.scientific.net/AMR.1040.943
Burkov, M. V. ; Panin, S. V. ; Lyubutin, P. S. ; Eremin, A. V. / Investigation of sensitivity of aluminum foil based strain sensors at fatigue damage evaluation of CFRP. High Technology: Research and Applications. Trans Tech Publications Ltd, 2014. стр. 943-948 (Advanced Materials Research).
@inproceedings{04c7b070c445496da4e4e498f1903fe1,
title = "Investigation of sensitivity of aluminum foil based strain sensors at fatigue damage evaluation of CFRP",
abstract = "For the development of a technique for cyclic deformation assessment using aluminum foil sensors glued onto the specimen surface the fatigue tests of carbon fiber reinforced polymer (CFRP) specimens were carried out. The DSLR camera mounted onto an optical microscope was used for capturing the images of sensors to reflect strain induced relief, which than was numerically estimated using various informative parameters in order to obtain the cyclic deformation assessment of composite. The results are discussed in view of application of this method for the development of Structural Health Monitoring (SHM) approach.",
keywords = "Carbon fiber composite, Fatigue, Smart sensor, Structural health monitoring",
author = "Burkov, {M. V.} and Panin, {S. V.} and Lyubutin, {P. S.} and Eremin, {A. V.}",
year = "2014",
month = "1",
day = "1",
doi = "10.4028/www.scientific.net/AMR.1040.943",
language = "English",
series = "Advanced Materials Research",
publisher = "Trans Tech Publications Ltd",
pages = "943--948",
booktitle = "High Technology",

}

TY - GEN

T1 - Investigation of sensitivity of aluminum foil based strain sensors at fatigue damage evaluation of CFRP

AU - Burkov, M. V.

AU - Panin, S. V.

AU - Lyubutin, P. S.

AU - Eremin, A. V.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - For the development of a technique for cyclic deformation assessment using aluminum foil sensors glued onto the specimen surface the fatigue tests of carbon fiber reinforced polymer (CFRP) specimens were carried out. The DSLR camera mounted onto an optical microscope was used for capturing the images of sensors to reflect strain induced relief, which than was numerically estimated using various informative parameters in order to obtain the cyclic deformation assessment of composite. The results are discussed in view of application of this method for the development of Structural Health Monitoring (SHM) approach.

AB - For the development of a technique for cyclic deformation assessment using aluminum foil sensors glued onto the specimen surface the fatigue tests of carbon fiber reinforced polymer (CFRP) specimens were carried out. The DSLR camera mounted onto an optical microscope was used for capturing the images of sensors to reflect strain induced relief, which than was numerically estimated using various informative parameters in order to obtain the cyclic deformation assessment of composite. The results are discussed in view of application of this method for the development of Structural Health Monitoring (SHM) approach.

KW - Carbon fiber composite

KW - Fatigue

KW - Smart sensor

KW - Structural health monitoring

UR - http://www.scopus.com/inward/record.url?scp=84913556579&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84913556579&partnerID=8YFLogxK

U2 - 10.4028/www.scientific.net/AMR.1040.943

DO - 10.4028/www.scientific.net/AMR.1040.943

M3 - Conference contribution

AN - SCOPUS:84913556579

T3 - Advanced Materials Research

SP - 943

EP - 948

BT - High Technology

PB - Trans Tech Publications Ltd

ER -