Investigation of anode foil stability at high-current electron accelerator

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Аннотация

Results of experimental studies of anode foil destruction mechanisms are presented. The experiments have been done on the accelerator with the following parameters: voltage - up to 500 kV, e-beam current - up to 10 kA, pulse duration (FWHM) - 60 ns, pulse repetition rate - up to 3 Hz. It was found out that the formation of cathode spots on the anode foil surface as well as the current in the diode during the positive post-pulses following the main negative pulse of the accelerating voltage are the main reasons for the foil life time limitation. The improvement of the diode impedance matching with the output impedance of the pulsed power generator decreases the energy of the post-pulses and leads to a longer life time of the anode foil. The introduction of an additional anode electrode forming with the cathode a vacuum crowbar switch practically excludes damages of the anode foil and increases its life time up to 105 pulses.

Язык оригиналаАнглийский
Название основной публикации2008 17th International Conference on High Power Particle Beams, BEAMS'08
СостояниеОпубликовано - 2008
Событие17th International Conference on High Power Particle Beams, BEAMS'08 - Xi'an, Китай
Продолжительность: 6 июл 200811 июл 2008

Другое

Другое17th International Conference on High Power Particle Beams, BEAMS'08
СтранаКитай
ГородXi'an
Период6.7.0811.7.08

ASJC Scopus subject areas

  • Nuclear and High Energy Physics

Fingerprint Подробные сведения о темах исследования «Investigation of anode foil stability at high-current electron accelerator». Вместе они формируют уникальный семантический отпечаток (fingerprint).

  • Цитировать

    Ezhov, VV., Krastelev, E. G., & Remnev, G. E. (2008). Investigation of anode foil stability at high-current electron accelerator. В 2008 17th International Conference on High Power Particle Beams, BEAMS'08 [6202936]