Infrared imaging diagnostics for parameters of powerful ion beams formed by a diode in a double-pulse mode

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

14 Цитирования (Scopus)

Выдержка

Infrared imaging diagnostics on the parameters of pulsed ion beams of gigawatt power is an effective method for rapid control. It allows for the measuring of energy density distribution at the target, optimization of an ion diode operation and control of the mode of target irradiation. Spatial resolution is of 0.9-1 mm, the sensitivity of a standard thermal camera provides registration of a thermal imprint per pulse at energy densities above 0.05 J/cm 2.

Язык оригиналаАнглийский
Название основной публикацииDigest of Technical Papers-IEEE International Pulsed Power Conference
Страницы334-340
Число страниц7
DOI
СостояниеОпубликовано - 2011
Событие18th IEEE International Pulsed Power Conference, PPC 2011 - Chicago, IL, Соединенные Штаты Америки
Продолжительность: 19 июн 201123 июн 2011

Другое

Другое18th IEEE International Pulsed Power Conference, PPC 2011
СтранаСоединенные Штаты Америки
ГородChicago, IL
Период19.6.1123.6.11

Отпечаток

Infrared imaging
Ion beams
Diodes
Cameras
Irradiation
Ions
Hot Temperature

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Energy Engineering and Power Technology

Цитировать

Isakova, Y. (2011). Infrared imaging diagnostics for parameters of powerful ion beams formed by a diode in a double-pulse mode. В Digest of Technical Papers-IEEE International Pulsed Power Conference (стр. 334-340). [6191440] https://doi.org/10.1109/PPC.2011.6191440

Infrared imaging diagnostics for parameters of powerful ion beams formed by a diode in a double-pulse mode. / Isakova, Yulia.

Digest of Technical Papers-IEEE International Pulsed Power Conference. 2011. стр. 334-340 6191440.

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Isakova, Y 2011, Infrared imaging diagnostics for parameters of powerful ion beams formed by a diode in a double-pulse mode. в Digest of Technical Papers-IEEE International Pulsed Power Conference., 6191440, стр. 334-340, Chicago, IL, Соединенные Штаты Америки, 19.6.11. https://doi.org/10.1109/PPC.2011.6191440
Isakova Y. Infrared imaging diagnostics for parameters of powerful ion beams formed by a diode in a double-pulse mode. В Digest of Technical Papers-IEEE International Pulsed Power Conference. 2011. стр. 334-340. 6191440 https://doi.org/10.1109/PPC.2011.6191440
Isakova, Yulia. / Infrared imaging diagnostics for parameters of powerful ion beams formed by a diode in a double-pulse mode. Digest of Technical Papers-IEEE International Pulsed Power Conference. 2011. стр. 334-340
@inproceedings{2a2b0d03944f485aabd17ee858aae78a,
title = "Infrared imaging diagnostics for parameters of powerful ion beams formed by a diode in a double-pulse mode",
abstract = "Infrared imaging diagnostics on the parameters of pulsed ion beams of gigawatt power is an effective method for rapid control. It allows for the measuring of energy density distribution at the target, optimization of an ion diode operation and control of the mode of target irradiation. Spatial resolution is of 0.9-1 mm, the sensitivity of a standard thermal camera provides registration of a thermal imprint per pulse at energy densities above 0.05 J/cm 2.",
author = "Yulia Isakova",
year = "2011",
doi = "10.1109/PPC.2011.6191440",
language = "English",
isbn = "9781457706295",
pages = "334--340",
booktitle = "Digest of Technical Papers-IEEE International Pulsed Power Conference",

}

TY - GEN

T1 - Infrared imaging diagnostics for parameters of powerful ion beams formed by a diode in a double-pulse mode

AU - Isakova, Yulia

PY - 2011

Y1 - 2011

N2 - Infrared imaging diagnostics on the parameters of pulsed ion beams of gigawatt power is an effective method for rapid control. It allows for the measuring of energy density distribution at the target, optimization of an ion diode operation and control of the mode of target irradiation. Spatial resolution is of 0.9-1 mm, the sensitivity of a standard thermal camera provides registration of a thermal imprint per pulse at energy densities above 0.05 J/cm 2.

AB - Infrared imaging diagnostics on the parameters of pulsed ion beams of gigawatt power is an effective method for rapid control. It allows for the measuring of energy density distribution at the target, optimization of an ion diode operation and control of the mode of target irradiation. Spatial resolution is of 0.9-1 mm, the sensitivity of a standard thermal camera provides registration of a thermal imprint per pulse at energy densities above 0.05 J/cm 2.

UR - http://www.scopus.com/inward/record.url?scp=84861368075&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84861368075&partnerID=8YFLogxK

U2 - 10.1109/PPC.2011.6191440

DO - 10.1109/PPC.2011.6191440

M3 - Conference contribution

AN - SCOPUS:84861368075

SN - 9781457706295

SP - 334

EP - 340

BT - Digest of Technical Papers-IEEE International Pulsed Power Conference

ER -