Influence of the configuration of the magnetic field of an ion diode on the parameters of an ion beam

Результат исследования: Материалы для журналаСтатья

6 Цитирования (Scopus)

Аннотация

The distribution of magnetic-field induction in the accelerating gap of an ion diode with external magnetic insulation is studied. The absence of a device for preliminary plasma production is a distinguishing feature of this diode. It is shown that a certain configuration of the magnetic field near the anode surface allows an increase in the ion-diode efficiency to 70%, and the ion-current density at the diode focus then reaches 350 A/cm2.

Язык оригиналаАнглийский
Страницы (с... по...)565-568
Количество страниц4
ЖурналInstruments and Experimental Techniques
Том52
Номер выпуска4
DOI
Статус публикацииОпубликовано - июл 2009