The pulse electric strength of dielectrics depends on the voltage of dc current impressed preliminarily. One of methods for the adjustment of the field in polyethylene of low density (PELD) is shown. The thickness of samples was 0,63 mm, voltage amplitude of positive or negative polarity varied from 15 to 43kV, time lag under voltage- 1-15 minutes. The service life test results have been presented. A conclusion has been made that the significant increase of the PELD service life may be obtained by the adjustment of the field distribution in a dielectric.

Язык оригиналаАнглийский
Страницы (с-по)76-79
Число страниц4
ЖурналElektrichestvo
Номер выпуска9
СостояниеОпубликовано - сен 1991

Отпечаток

Service life
Polyethylenes
Electric potential

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Цитировать

How preliminary electrization of polyethylene influences its service life in an electric impulse field. / Gefle, O. S.; Lopatkin, Sergey Anatolievich.

В: Elektrichestvo, № 9, 09.1991, стр. 76-79.

Результат исследований: Материалы для журналаСтатья

@article{59666b8fe2b14db9a5cbd39cacef2b5e,
title = "How preliminary electrization of polyethylene influences its service life in an electric impulse field",
abstract = "The pulse electric strength of dielectrics depends on the voltage of dc current impressed preliminarily. One of methods for the adjustment of the field in polyethylene of low density (PELD) is shown. The thickness of samples was 0,63 mm, voltage amplitude of positive or negative polarity varied from 15 to 43kV, time lag under voltage- 1-15 minutes. The service life test results have been presented. A conclusion has been made that the significant increase of the PELD service life may be obtained by the adjustment of the field distribution in a dielectric.",
author = "Gefle, {O. S.} and Lopatkin, {Sergey Anatolievich}",
year = "1991",
month = "9",
language = "English",
pages = "76--79",
journal = "Elektrichestvo",
issn = "0013-5380",
publisher = "JSC Znack",
number = "9",

}

TY - JOUR

T1 - How preliminary electrization of polyethylene influences its service life in an electric impulse field

AU - Gefle, O. S.

AU - Lopatkin, Sergey Anatolievich

PY - 1991/9

Y1 - 1991/9

N2 - The pulse electric strength of dielectrics depends on the voltage of dc current impressed preliminarily. One of methods for the adjustment of the field in polyethylene of low density (PELD) is shown. The thickness of samples was 0,63 mm, voltage amplitude of positive or negative polarity varied from 15 to 43kV, time lag under voltage- 1-15 minutes. The service life test results have been presented. A conclusion has been made that the significant increase of the PELD service life may be obtained by the adjustment of the field distribution in a dielectric.

AB - The pulse electric strength of dielectrics depends on the voltage of dc current impressed preliminarily. One of methods for the adjustment of the field in polyethylene of low density (PELD) is shown. The thickness of samples was 0,63 mm, voltage amplitude of positive or negative polarity varied from 15 to 43kV, time lag under voltage- 1-15 minutes. The service life test results have been presented. A conclusion has been made that the significant increase of the PELD service life may be obtained by the adjustment of the field distribution in a dielectric.

UR - http://www.scopus.com/inward/record.url?scp=0026214744&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026214744&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0026214744

SP - 76

EP - 79

JO - Elektrichestvo

JF - Elektrichestvo

SN - 0013-5380

IS - 9

ER -