External triggering of cold cathode thyratron in the system with blocking electrodes

N. V. Landl, Y. D. Korolev, O. B. Frants, I. A. Shemyakin, V. G. Geyman

    Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

    Выдержка

    One of the widely used systems for external triggering of the cold cathode thyratron (pseudospark switch) is based on a trigger unit with an auxiliary glow discharge. In most cases, the trigger unit is mounted at the grounded cathode. However, in some cases a specific requirement for triggering is demanded, namely, a trigger unit has to be located at potential cathode electrode. Direct application of the previous experience as applied to these cases leads to a rather intricate design for both mechanical parts of the trigger unit and electric circuit. This paper describes a simple trigger system for such conditions. Simultaneously with the function of external triggering, the system provides the so-called blocking effect, i.e. increasing a pulsed breakdown voltage and preventing the accident breakdowns in the regime of high pulse repetition rate.

    Язык оригиналаАнглийский
    Название основной публикацииProceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV
    ИздательInstitute of Electrical and Electronics Engineers Inc.
    Страницы373-376
    Число страниц4
    ISBN (печатное издание)9781479967506
    DOI
    СостояниеОпубликовано - 18 ноя 2014
    Событие26th International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV 2014 - Mumbai, Индия
    Продолжительность: 28 сен 20143 окт 2014

    Другое

    Другое26th International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV 2014
    СтранаИндия
    ГородMumbai
    Период28.9.143.10.14

    Отпечаток

    Cathodes
    Electrodes
    Pulse repetition rate
    Glow discharges
    Electric breakdown
    Accidents
    Switches
    Networks (circuits)

    ASJC Scopus subject areas

    • Computer Networks and Communications
    • Software

    Цитировать

    Landl, N. V., Korolev, Y. D., Frants, O. B., Shemyakin, I. A., & Geyman, V. G. (2014). External triggering of cold cathode thyratron in the system with blocking electrodes. В Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV (стр. 373-376). [6961697] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/DEIV.2014.6961697

    External triggering of cold cathode thyratron in the system with blocking electrodes. / Landl, N. V.; Korolev, Y. D.; Frants, O. B.; Shemyakin, I. A.; Geyman, V. G.

    Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV. Institute of Electrical and Electronics Engineers Inc., 2014. стр. 373-376 6961697.

    Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

    Landl, NV, Korolev, YD, Frants, OB, Shemyakin, IA & Geyman, VG 2014, External triggering of cold cathode thyratron in the system with blocking electrodes. в Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV., 6961697, Institute of Electrical and Electronics Engineers Inc., стр. 373-376, Mumbai, Индия, 28.9.14. https://doi.org/10.1109/DEIV.2014.6961697
    Landl NV, Korolev YD, Frants OB, Shemyakin IA, Geyman VG. External triggering of cold cathode thyratron in the system with blocking electrodes. В Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV. Institute of Electrical and Electronics Engineers Inc. 2014. стр. 373-376. 6961697 https://doi.org/10.1109/DEIV.2014.6961697
    Landl, N. V. ; Korolev, Y. D. ; Frants, O. B. ; Shemyakin, I. A. ; Geyman, V. G. / External triggering of cold cathode thyratron in the system with blocking electrodes. Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV. Institute of Electrical and Electronics Engineers Inc., 2014. стр. 373-376
    @inproceedings{d14d0a3818304983a0b63b54e8e6e501,
    title = "External triggering of cold cathode thyratron in the system with blocking electrodes",
    abstract = "One of the widely used systems for external triggering of the cold cathode thyratron (pseudospark switch) is based on a trigger unit with an auxiliary glow discharge. In most cases, the trigger unit is mounted at the grounded cathode. However, in some cases a specific requirement for triggering is demanded, namely, a trigger unit has to be located at potential cathode electrode. Direct application of the previous experience as applied to these cases leads to a rather intricate design for both mechanical parts of the trigger unit and electric circuit. This paper describes a simple trigger system for such conditions. Simultaneously with the function of external triggering, the system provides the so-called blocking effect, i.e. increasing a pulsed breakdown voltage and preventing the accident breakdowns in the regime of high pulse repetition rate.",
    author = "Landl, {N. V.} and Korolev, {Y. D.} and Frants, {O. B.} and Shemyakin, {I. A.} and Geyman, {V. G.}",
    year = "2014",
    month = "11",
    day = "18",
    doi = "10.1109/DEIV.2014.6961697",
    language = "English",
    isbn = "9781479967506",
    pages = "373--376",
    booktitle = "Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV",
    publisher = "Institute of Electrical and Electronics Engineers Inc.",

    }

    TY - GEN

    T1 - External triggering of cold cathode thyratron in the system with blocking electrodes

    AU - Landl, N. V.

    AU - Korolev, Y. D.

    AU - Frants, O. B.

    AU - Shemyakin, I. A.

    AU - Geyman, V. G.

    PY - 2014/11/18

    Y1 - 2014/11/18

    N2 - One of the widely used systems for external triggering of the cold cathode thyratron (pseudospark switch) is based on a trigger unit with an auxiliary glow discharge. In most cases, the trigger unit is mounted at the grounded cathode. However, in some cases a specific requirement for triggering is demanded, namely, a trigger unit has to be located at potential cathode electrode. Direct application of the previous experience as applied to these cases leads to a rather intricate design for both mechanical parts of the trigger unit and electric circuit. This paper describes a simple trigger system for such conditions. Simultaneously with the function of external triggering, the system provides the so-called blocking effect, i.e. increasing a pulsed breakdown voltage and preventing the accident breakdowns in the regime of high pulse repetition rate.

    AB - One of the widely used systems for external triggering of the cold cathode thyratron (pseudospark switch) is based on a trigger unit with an auxiliary glow discharge. In most cases, the trigger unit is mounted at the grounded cathode. However, in some cases a specific requirement for triggering is demanded, namely, a trigger unit has to be located at potential cathode electrode. Direct application of the previous experience as applied to these cases leads to a rather intricate design for both mechanical parts of the trigger unit and electric circuit. This paper describes a simple trigger system for such conditions. Simultaneously with the function of external triggering, the system provides the so-called blocking effect, i.e. increasing a pulsed breakdown voltage and preventing the accident breakdowns in the regime of high pulse repetition rate.

    UR - http://www.scopus.com/inward/record.url?scp=84919395507&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84919395507&partnerID=8YFLogxK

    U2 - 10.1109/DEIV.2014.6961697

    DO - 10.1109/DEIV.2014.6961697

    M3 - Conference contribution

    AN - SCOPUS:84919395507

    SN - 9781479967506

    SP - 373

    EP - 376

    BT - Proceedings - International Symposium on Discharges and Electrical Insulation in Vacuum, ISDEIV

    PB - Institute of Electrical and Electronics Engineers Inc.

    ER -