Evaluation of freeze-thaw damage to reinforced concrete based on the parameters of electric response to mechanical impact

T. V. Fursa, D. D. Dann, M. V. Petrov

Результат исследований: Материалы для журналаСтатья

7 Цитирования (Scopus)

Аннотация

The article examines damage caused to steel and fiberglass reinforcement concrete by freeze-thaw cycles in saline medium conditions. After 12 freeze-thawing cycles, the concrete-rebar bond strength decreases by 30% for steel and by 40% for fiberglass. A method of evaluating the concrete-rebar bond strength is proposed. The evaluation procedure is based on measuring electric response to mechanical impact. Energy attenuation coefficient and the signals' spectrum centroid could be used as the diagnostic criteria for the evaluation of concrete-rebar bond strength. After 12 FT cycles the electric signal's energy attenuation coefficient increases by about 40–45%, and the maximum signals' spectrum centroid increasing reaches about 8 kHz. The proposed method can be used to monitor the evolution of concrete-rebar bond strength in complex climate testing conditions.

Язык оригиналаАнглийский
Страницы (с-по)451-462
Число страниц12
ЖурналConstruction and Building Materials
Том155
DOI
СостояниеОпубликовано - 30 ноя 2017

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Materials Science(all)

Fingerprint Подробные сведения о темах исследования «Evaluation of freeze-thaw damage to reinforced concrete based on the parameters of electric response to mechanical impact». Вместе они формируют уникальный семантический отпечаток (fingerprint).

  • Цитировать