Аннотация
The results of study of the electric strength, tanδ and partial discharge parameters in PET film insulation with different thickness are represented in this paper. It was established that the mechanism of a polymeric films breakdown has ionization nature due to the fringing effect and non-ideal contact between electrodes and dielectric. The experimental results of study of the ignition voltage of critical partial discharges which can result in both the destruction of polymeric films and sharp decrease of the Q-factor are presented in this paper.
Язык оригинала | Английский |
---|---|
Название основной публикации | Proceedings - 9th Russian-Korean International Symposium on Science and Technology, KORUS-2005 |
Страницы | 143-146 |
Число страниц | 4 |
Том | 1 |
DOI | |
Состояние | Опубликовано - 2005 |
Событие | 9th Russian-Korean International Symposium on Science and Technology, KORUS-2005 - Novosibirsk, Российская Федерация Продолжительность: 26 июн 2005 → 2 июл 2005 |
Другое
Другое | 9th Russian-Korean International Symposium on Science and Technology, KORUS-2005 |
---|---|
Страна | Российская Федерация |
Город | Novosibirsk |
Период | 26.6.05 → 2.7.05 |
ASJC Scopus subject areas
- Engineering(all)