The criterion for distinguishing defects is investigated as a function of the ratio of the dimensions of the scanning spot and of the defect, taking into account the frequency characteristics of pyroelectric and photovoltaic receivers. The optimum ratio of these quantities which ensures maximum sensitivity in active thermal monitoring is established.

Язык оригиналаАнглийский
Страницы (с-по)269-272
Число страниц4
ЖурналThe Soviet journal of nondestructive testing
Том20
Номер выпуска4
СостояниеОпубликовано - апр 1984

Отпечаток

Scanning
Defects
Testing
Monitoring
Hot Temperature

ASJC Scopus subject areas

  • Engineering(all)

Цитировать

EFFECT OF THE SIZE OF THE SCANNING SPOT AND THE FREQUENCY CHARACTERISTICS OF THE PHOTORECEIVER ON THE SENSITIVITY OF ACTIVE THERMAL TESTING. / Vavilov, V. P.; Storozhenko, V. A.; Ivanishina, Z. V.

В: The Soviet journal of nondestructive testing, Том 20, № 4, 04.1984, стр. 269-272.

Результат исследований: Материалы для журналаСтатья

@article{349b91945abf4318afaf975f1f96ab11,
title = "EFFECT OF THE SIZE OF THE SCANNING SPOT AND THE FREQUENCY CHARACTERISTICS OF THE PHOTORECEIVER ON THE SENSITIVITY OF ACTIVE THERMAL TESTING.",
abstract = "The criterion for distinguishing defects is investigated as a function of the ratio of the dimensions of the scanning spot and of the defect, taking into account the frequency characteristics of pyroelectric and photovoltaic receivers. The optimum ratio of these quantities which ensures maximum sensitivity in active thermal monitoring is established.",
author = "Vavilov, {V. P.} and Storozhenko, {V. A.} and Ivanishina, {Z. V.}",
year = "1984",
month = "4",
language = "English",
volume = "20",
pages = "269--272",
journal = "Soviet Journal of Nondestructive Testing",
issn = "0038-5492",
publisher = "Consultants Bureau",
number = "4",

}

TY - JOUR

T1 - EFFECT OF THE SIZE OF THE SCANNING SPOT AND THE FREQUENCY CHARACTERISTICS OF THE PHOTORECEIVER ON THE SENSITIVITY OF ACTIVE THERMAL TESTING.

AU - Vavilov, V. P.

AU - Storozhenko, V. A.

AU - Ivanishina, Z. V.

PY - 1984/4

Y1 - 1984/4

N2 - The criterion for distinguishing defects is investigated as a function of the ratio of the dimensions of the scanning spot and of the defect, taking into account the frequency characteristics of pyroelectric and photovoltaic receivers. The optimum ratio of these quantities which ensures maximum sensitivity in active thermal monitoring is established.

AB - The criterion for distinguishing defects is investigated as a function of the ratio of the dimensions of the scanning spot and of the defect, taking into account the frequency characteristics of pyroelectric and photovoltaic receivers. The optimum ratio of these quantities which ensures maximum sensitivity in active thermal monitoring is established.

UR - http://www.scopus.com/inward/record.url?scp=0021417366&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021417366&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0021417366

VL - 20

SP - 269

EP - 272

JO - Soviet Journal of Nondestructive Testing

JF - Soviet Journal of Nondestructive Testing

SN - 0038-5492

IS - 4

ER -