Effect of the initial load parameters on the K- hell output of al planar wire arrays operating in the microsecond implosion regime

A. Shishlov, S. Chaikovsky, A. Fedunin, F. Fursov, V. Kokshenev, N. Kurmaev, A. Labetsky, V. Oreshkin, A. Rousskikh, N. Labetskaya

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

3 Цитирования (Scopus)

Выдержка

A set of microsecond implosion experiments was carried on the GIT-12 generator to study the radiative performance of Al planar wire arrays. The load parameters such as a wire diameter, a gap between the wires, the number of wires, and the total planar wire mass and width were varied during the experiments, however the implosion time and the peak implosion current were almost the same for all load configurations. This ensured equal energy deposition to the plasma due to kinetic mechanisms for all load configurations. Two implosion regimes with the implosion times of 1050 ns and 850 ns were investigated. The experimental data on the K-shell radiation yield and power at varying load parameters are presented.

Язык оригиналаАнглийский
Название основной публикацииAIP Conference Proceedings
Страницы137-140
Число страниц4
Том1088
DOI
СостояниеОпубликовано - 2009
Опубликовано для внешнего пользованияДа
Событие7th International Conference on Dense Z-Pinches - Alexandria, VA, Соединенные Штаты Америки
Продолжительность: 12 авг 200821 авг 2008

Другое

Другое7th International Conference on Dense Z-Pinches
СтранаСоединенные Штаты Америки
ГородAlexandria, VA
Период12.8.0821.8.08

Отпечаток

implosions
wire
output
configurations
generators
kinetics
radiation
energy

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Цитировать

Shishlov, A., Chaikovsky, S., Fedunin, A., Fursov, F., Kokshenev, V., Kurmaev, N., ... Labetskaya, N. (2009). Effect of the initial load parameters on the K- hell output of al planar wire arrays operating in the microsecond implosion regime. В AIP Conference Proceedings (Том 1088, стр. 137-140) https://doi.org/10.1063/1.3079712

Effect of the initial load parameters on the K- hell output of al planar wire arrays operating in the microsecond implosion regime. / Shishlov, A.; Chaikovsky, S.; Fedunin, A.; Fursov, F.; Kokshenev, V.; Kurmaev, N.; Labetsky, A.; Oreshkin, V.; Rousskikh, A.; Labetskaya, N.

AIP Conference Proceedings. Том 1088 2009. стр. 137-140.

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Shishlov, A, Chaikovsky, S, Fedunin, A, Fursov, F, Kokshenev, V, Kurmaev, N, Labetsky, A, Oreshkin, V, Rousskikh, A & Labetskaya, N 2009, Effect of the initial load parameters on the K- hell output of al planar wire arrays operating in the microsecond implosion regime. в AIP Conference Proceedings. том. 1088, стр. 137-140, Alexandria, VA, Соединенные Штаты Америки, 12.8.08. https://doi.org/10.1063/1.3079712
Shishlov A, Chaikovsky S, Fedunin A, Fursov F, Kokshenev V, Kurmaev N и соавт. Effect of the initial load parameters on the K- hell output of al planar wire arrays operating in the microsecond implosion regime. В AIP Conference Proceedings. Том 1088. 2009. стр. 137-140 https://doi.org/10.1063/1.3079712
Shishlov, A. ; Chaikovsky, S. ; Fedunin, A. ; Fursov, F. ; Kokshenev, V. ; Kurmaev, N. ; Labetsky, A. ; Oreshkin, V. ; Rousskikh, A. ; Labetskaya, N. / Effect of the initial load parameters on the K- hell output of al planar wire arrays operating in the microsecond implosion regime. AIP Conference Proceedings. Том 1088 2009. стр. 137-140
@inproceedings{14541e8f6d3d447295af4cb47893447c,
title = "Effect of the initial load parameters on the K- hell output of al planar wire arrays operating in the microsecond implosion regime",
abstract = "A set of microsecond implosion experiments was carried on the GIT-12 generator to study the radiative performance of Al planar wire arrays. The load parameters such as a wire diameter, a gap between the wires, the number of wires, and the total planar wire mass and width were varied during the experiments, however the implosion time and the peak implosion current were almost the same for all load configurations. This ensured equal energy deposition to the plasma due to kinetic mechanisms for all load configurations. Two implosion regimes with the implosion times of 1050 ns and 850 ns were investigated. The experimental data on the K-shell radiation yield and power at varying load parameters are presented.",
keywords = "K-shell radiation, Planar wire arrays, Plasma radiation source, Z-pinch",
author = "A. Shishlov and S. Chaikovsky and A. Fedunin and F. Fursov and V. Kokshenev and N. Kurmaev and A. Labetsky and V. Oreshkin and A. Rousskikh and N. Labetskaya",
year = "2009",
doi = "10.1063/1.3079712",
language = "English",
volume = "1088",
pages = "137--140",
booktitle = "AIP Conference Proceedings",

}

TY - GEN

T1 - Effect of the initial load parameters on the K- hell output of al planar wire arrays operating in the microsecond implosion regime

AU - Shishlov, A.

AU - Chaikovsky, S.

AU - Fedunin, A.

AU - Fursov, F.

AU - Kokshenev, V.

AU - Kurmaev, N.

AU - Labetsky, A.

AU - Oreshkin, V.

AU - Rousskikh, A.

AU - Labetskaya, N.

PY - 2009

Y1 - 2009

N2 - A set of microsecond implosion experiments was carried on the GIT-12 generator to study the radiative performance of Al planar wire arrays. The load parameters such as a wire diameter, a gap between the wires, the number of wires, and the total planar wire mass and width were varied during the experiments, however the implosion time and the peak implosion current were almost the same for all load configurations. This ensured equal energy deposition to the plasma due to kinetic mechanisms for all load configurations. Two implosion regimes with the implosion times of 1050 ns and 850 ns were investigated. The experimental data on the K-shell radiation yield and power at varying load parameters are presented.

AB - A set of microsecond implosion experiments was carried on the GIT-12 generator to study the radiative performance of Al planar wire arrays. The load parameters such as a wire diameter, a gap between the wires, the number of wires, and the total planar wire mass and width were varied during the experiments, however the implosion time and the peak implosion current were almost the same for all load configurations. This ensured equal energy deposition to the plasma due to kinetic mechanisms for all load configurations. Two implosion regimes with the implosion times of 1050 ns and 850 ns were investigated. The experimental data on the K-shell radiation yield and power at varying load parameters are presented.

KW - K-shell radiation

KW - Planar wire arrays

KW - Plasma radiation source

KW - Z-pinch

UR - http://www.scopus.com/inward/record.url?scp=63849303072&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=63849303072&partnerID=8YFLogxK

U2 - 10.1063/1.3079712

DO - 10.1063/1.3079712

M3 - Conference contribution

AN - SCOPUS:63849303072

VL - 1088

SP - 137

EP - 140

BT - AIP Conference Proceedings

ER -