Determination of roxarsone using carbon paste and amberlite LA2 modified carbon paste electrodes

Rahmalan Ahamad, Jiri Barek, A. Rahim Yusoff, Siti Morin Sinaga, Jiri Zima

Результат исследований: Материалы для журналаСтатьярецензирование

15 Цитирования (Scopus)

Аннотация

The methods for determination of the growth promoter 4-hydroxy-3-nitrobenzenearsonic acid (Roxarsone) in veterinary product and in poultry drinks have been developed using differential pulse voltammetry with carbon paste and Amberlite LA2 chemically modified carbon paste electrodes. Optimal conditions have been found for Roxarsone determination with nonmodified carbon paste electrodes with limit of determination being 3 μmol L-1. The sensitivity of the determination was further improved through Amberlite LA2 modification of the carbon paste with limit of determination being 0.1 μmol L-1. Modification also enabled preliminary accumulation of Roxarsone with the exchange of the supporting electrolyte.

Язык оригиналаАнглийский
Страницы (с-по)1220-1226
Число страниц7
ЖурналElectroanalysis
Том12
Номер выпуска15
DOI
СостояниеОпубликовано - 16 дек 2000
Опубликовано для внешнего пользованияДа

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry

Fingerprint Подробные сведения о темах исследования «Determination of roxarsone using carbon paste and amberlite LA2 modified carbon paste electrodes». Вместе они формируют уникальный семантический отпечаток (fingerprint).

Цитировать