Determination of enamel insulation corona resistance by high- frequency modulated pulses

Результат исследований: Материалы для журналаСтатья

5 Цитирования (Scopus)

Аннотация

In the article test equipment is described for corona resistance testing of enameled winding wire samples. The primary element of equipment is generator producing test voltage with necessary waveform and magnitude according to the required PWM. Test conditions are accurately simulated by operational loads on a winding insulation (simultaneous impact of temperature and corona discharges). Obtained results of average time to breakdown show that the enamel insulation modified by silicon nanoparticles has a maximum corona resistance.

Язык оригиналаАнглийский
Номер статьи012094
ЖурналIOP Conference Series: Materials Science and Engineering
Том81
Номер выпуска1
DOI
СостояниеОпубликовано - 23 апр 2015

ASJC Scopus subject areas

  • Engineering(all)
  • Materials Science(all)

Fingerprint Подробные сведения о темах исследования «Determination of enamel insulation corona resistance by high- frequency modulated pulses». Вместе они формируют уникальный семантический отпечаток (fingerprint).