Designing transfer function with the required direct performance measures based on the Laplace transform

S. V. Efimov, V. V. Kurgankin, S. V. Zamyatin

Результат исследований: Материалы для журналаСтатья

2 Цитирования (Scopus)

Выдержка

An approach is proposed to design transfer functions with prescribed direct measures of transient performance: overshoot and setting time. A technique for designing such functions is developed. A numerical example is given.

Язык оригиналаАнглийский
Страницы (с-по)348-353
Число страниц6
ЖурналOptoelectronics, Instrumentation and Data Processing
Том50
Номер выпуска4
DOI
СостояниеОпубликовано - 1 июл 2014

Отпечаток

Laplace transforms
transfer functions
Transfer functions

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Condensed Matter Physics
  • Instrumentation

Цитировать

Designing transfer function with the required direct performance measures based on the Laplace transform. / Efimov, S. V.; Kurgankin, V. V.; Zamyatin, S. V.

В: Optoelectronics, Instrumentation and Data Processing, Том 50, № 4, 01.07.2014, стр. 348-353.

Результат исследований: Материалы для журналаСтатья

@article{395bf11423114e82838fb25d28b4df4d,
title = "Designing transfer function with the required direct performance measures based on the Laplace transform",
abstract = "An approach is proposed to design transfer functions with prescribed direct measures of transient performance: overshoot and setting time. A technique for designing such functions is developed. A numerical example is given.",
keywords = "automatic control system, root measures of performance, transient",
author = "Efimov, {S. V.} and Kurgankin, {V. V.} and Zamyatin, {S. V.}",
year = "2014",
month = "7",
day = "1",
doi = "10.3103/S8756699014040049",
language = "English",
volume = "50",
pages = "348--353",
journal = "Optoelectronics, Instrumentation and Data Processing",
issn = "8756-6990",
publisher = "Allerton Press Inc.",
number = "4",

}

TY - JOUR

T1 - Designing transfer function with the required direct performance measures based on the Laplace transform

AU - Efimov, S. V.

AU - Kurgankin, V. V.

AU - Zamyatin, S. V.

PY - 2014/7/1

Y1 - 2014/7/1

N2 - An approach is proposed to design transfer functions with prescribed direct measures of transient performance: overshoot and setting time. A technique for designing such functions is developed. A numerical example is given.

AB - An approach is proposed to design transfer functions with prescribed direct measures of transient performance: overshoot and setting time. A technique for designing such functions is developed. A numerical example is given.

KW - automatic control system

KW - root measures of performance

KW - transient

UR - http://www.scopus.com/inward/record.url?scp=84908069254&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84908069254&partnerID=8YFLogxK

U2 - 10.3103/S8756699014040049

DO - 10.3103/S8756699014040049

M3 - Article

AN - SCOPUS:84908069254

VL - 50

SP - 348

EP - 353

JO - Optoelectronics, Instrumentation and Data Processing

JF - Optoelectronics, Instrumentation and Data Processing

SN - 8756-6990

IS - 4

ER -