Comparing the Efficiency of Ultrasonic Infrared Thermography under High-Power and Resonant Stimulation of Impact Damage in a CFRP Composite

D. A. Derusova, V. P. Vavilov, Xingwang Guo, N. V. Druzhinin

Результат исследований: Материалы для журналаСтатьярецензирование

4 Цитирования (Scopus)

Аннотация

The quality control of composite materials remains an important topic of research in nondestructive testing (NDT) of modern materials, in particular, the ones intended for aerospace industry. Over the last decade, there has been a noticeable increase in interest to the ultrasonic stimulation of tested materials and analysis of dynamic temperature distributions. This method is commonly implemented with two techniques, viz. high-power stimulation at a fixed acoustic-signal frequency and low-power resonant ultrasonic stimulation. Results are provided on comparing the above ultrasonic NDT methods using the example of an impact damage in a graphite epoxy-filled composite. The comparison is made based on the criteria of temperature signals, revealed flawed zone, and productivity of testing.

Язык оригиналаАнглийский
Страницы (с-по)356-362
Число страниц7
ЖурналRussian Journal of Nondestructive Testing
Том54
Номер выпуска5
DOI
СостояниеОпубликовано - 1 мая 2018

ASJC Scopus subject areas

  • Materials Science(all)
  • Condensed Matter Physics
  • Mechanics of Materials
  • Mechanical Engineering

Fingerprint Подробные сведения о темах исследования «Comparing the Efficiency of Ultrasonic Infrared Thermography under High-Power and Resonant Stimulation of Impact Damage in a CFRP Composite». Вместе они формируют уникальный семантический отпечаток (fingerprint).