Comparative analysis of using natural and radiogenic lead as heat-transfer agent in fast reactors

R. A. Laas, R. V. Gizbrekht, P. A. Komarov, V. N. Nesterov

Результат исследований: Материалы для журнала

Выдержка

Fast reactors with lead coolant have several advantages over analogues. Performance can be further improved by replacement of natural composition lead with radiogenic one. Thus, two main issues need to be addressed: induced radioactivity in coolant and efficient neutron multiplication factor in the core will be changed and need to be estimated. To address these issues analysis of the scheme of the nuclear transformations in the lead heat-transfer agent in the process of radiation was carried out. Induced radioactivity of radiogenic and natural lead has been studied. It is shown that replacement of lead affects multiplication factor in a certain way. Application of radiogenic lead can significantly affect reactor operation.

Язык оригиналаАнглийский
Номер статьи012024
ЖурналIOP Conference Series: Materials Science and Engineering
Том135
Номер выпуска1
DOI
СостояниеОпубликовано - 2 авг 2016
Событие8th International Scientific Conference on Issues of Physics and Technology in Science, Industry and Medicine - Tomsk, Российская Федерация
Продолжительность: 1 июн 20163 июн 2016

Отпечаток

Fast reactors
Lead
Heat transfer
Radioactivity
Coolants
Reactor operation
Neutrons
Radiation
Chemical analysis

ASJC Scopus subject areas

  • Materials Science(all)
  • Engineering(all)

Цитировать

Comparative analysis of using natural and radiogenic lead as heat-transfer agent in fast reactors. / Laas, R. A.; Gizbrekht, R. V.; Komarov, P. A.; Nesterov, V. N.

В: IOP Conference Series: Materials Science and Engineering, Том 135, № 1, 012024, 02.08.2016.

Результат исследований: Материалы для журнала

@article{bd2c82aabbb84399b053b299e491e232,
title = "Comparative analysis of using natural and radiogenic lead as heat-transfer agent in fast reactors",
abstract = "Fast reactors with lead coolant have several advantages over analogues. Performance can be further improved by replacement of natural composition lead with radiogenic one. Thus, two main issues need to be addressed: induced radioactivity in coolant and efficient neutron multiplication factor in the core will be changed and need to be estimated. To address these issues analysis of the scheme of the nuclear transformations in the lead heat-transfer agent in the process of radiation was carried out. Induced radioactivity of radiogenic and natural lead has been studied. It is shown that replacement of lead affects multiplication factor in a certain way. Application of radiogenic lead can significantly affect reactor operation.",
author = "Laas, {R. A.} and Gizbrekht, {R. V.} and Komarov, {P. A.} and Nesterov, {V. N.}",
year = "2016",
month = "8",
day = "2",
doi = "10.1088/1757-899X/135/1/012024",
language = "English",
volume = "135",
journal = "IOP Conference Series: Materials Science and Engineering",
issn = "1757-8981",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - Comparative analysis of using natural and radiogenic lead as heat-transfer agent in fast reactors

AU - Laas, R. A.

AU - Gizbrekht, R. V.

AU - Komarov, P. A.

AU - Nesterov, V. N.

PY - 2016/8/2

Y1 - 2016/8/2

N2 - Fast reactors with lead coolant have several advantages over analogues. Performance can be further improved by replacement of natural composition lead with radiogenic one. Thus, two main issues need to be addressed: induced radioactivity in coolant and efficient neutron multiplication factor in the core will be changed and need to be estimated. To address these issues analysis of the scheme of the nuclear transformations in the lead heat-transfer agent in the process of radiation was carried out. Induced radioactivity of radiogenic and natural lead has been studied. It is shown that replacement of lead affects multiplication factor in a certain way. Application of radiogenic lead can significantly affect reactor operation.

AB - Fast reactors with lead coolant have several advantages over analogues. Performance can be further improved by replacement of natural composition lead with radiogenic one. Thus, two main issues need to be addressed: induced radioactivity in coolant and efficient neutron multiplication factor in the core will be changed and need to be estimated. To address these issues analysis of the scheme of the nuclear transformations in the lead heat-transfer agent in the process of radiation was carried out. Induced radioactivity of radiogenic and natural lead has been studied. It is shown that replacement of lead affects multiplication factor in a certain way. Application of radiogenic lead can significantly affect reactor operation.

UR - http://www.scopus.com/inward/record.url?scp=84995543189&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84995543189&partnerID=8YFLogxK

U2 - 10.1088/1757-899X/135/1/012024

DO - 10.1088/1757-899X/135/1/012024

M3 - Conference article

AN - SCOPUS:84995543189

VL - 135

JO - IOP Conference Series: Materials Science and Engineering

JF - IOP Conference Series: Materials Science and Engineering

SN - 1757-8981

IS - 1

M1 - 012024

ER -