Characteristics of large-area position-sensitive scintillation detectors

Yu V. Vasil'chenko, A. N. Gulida, G. N. Dudkin, V. N. Padalko

Результат исследований: Материалы для журналаСтатьярецензирование

4 Цитирования (Scopus)

Аннотация

We describe a design and present results of the examination of the characteristics of five types of polymethyl-methacrylate-based large-area position-sensitive scintillation detectors differing in the way the light is extracted to the photomultiplier tubes (PMT), in dimensions (120 × 100 × 3 and 160 × 140 × 3 cm), in the light attenuation length in the scintillator, and in the type of PMTs used. To obtain the coordinates of the point where the particle traverses the scintillator, the PMT signal amplitudes were analyzed. The factors affecting the coordinate resolution of the detectors were studied. The detector with dimensions 160 × 140 × 3 cm has a coordinate resolution of 15 cm, a time resolution of 2.2 ns, and a detection efficiency of 0.995.

Язык оригиналаАнглийский
Страницы (с-по)176-182
Число страниц7
ЖурналInstruments and Experimental Techniques
Том41
Номер выпуска2
СостояниеОпубликовано - 1998

ASJC Scopus subject areas

  • Engineering (miscellaneous)
  • Instrumentation

Fingerprint Подробные сведения о темах исследования «Characteristics of large-area position-sensitive scintillation detectors». Вместе они формируют уникальный семантический отпечаток (fingerprint).