Channeling and parametric X-ray studies at the SAGA Light Source

Y. Takabayashi, K. B. Korotchenko, Yu L. Pivovarov, T. A. Tukhfatullin

Результат исследований: Материалы для журналаСтатья

8 Цитирования (Scopus)

Выдержка

We present experimental results on channeling and parametric X-ray radiation obtained using a 255-MeV electron beam from an injector linac at the SAGA Light Source. Using a screen monitor, we observed both channeling phenomena and doughnut scattering by measuring the profile of an electron beam transmitted through a 20-μm-thick Si crystal. We also measured the angular distribution of parametric X-ray radiation using an imaging plate as a two-dimensional X-ray detector. The obtained results are in good agreement with theory. The final goal of these studies is the first observation of diffracted channeling radiation, and our strategy for achieving this is discussed.

Язык оригиналаАнглийский
Страницы (с-по)105-109
Число страниц5
ЖурналNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
Том315
DOI
СостояниеОпубликовано - 15 ноя 2013

Отпечаток

Light sources
light sources
Radiation
X rays
Electron beams
radiation
electron beams
x rays
Angular distribution
injectors
monitors
angular distribution
Scattering
Detectors
Imaging techniques
Crystals
detectors
profiles
scattering
crystals

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Цитировать

Channeling and parametric X-ray studies at the SAGA Light Source. / Takabayashi, Y.; Korotchenko, K. B.; Pivovarov, Yu L.; Tukhfatullin, T. A.

В: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, Том 315, 15.11.2013, стр. 105-109.

Результат исследований: Материалы для журналаСтатья

@article{cb33058a46d04cdb8db68601c0d4985a,
title = "Channeling and parametric X-ray studies at the SAGA Light Source",
abstract = "We present experimental results on channeling and parametric X-ray radiation obtained using a 255-MeV electron beam from an injector linac at the SAGA Light Source. Using a screen monitor, we observed both channeling phenomena and doughnut scattering by measuring the profile of an electron beam transmitted through a 20-μm-thick Si crystal. We also measured the angular distribution of parametric X-ray radiation using an imaging plate as a two-dimensional X-ray detector. The obtained results are in good agreement with theory. The final goal of these studies is the first observation of diffracted channeling radiation, and our strategy for achieving this is discussed.",
keywords = "Channeling, Diffracted channeling radiation, Parametric x-ray radiation",
author = "Y. Takabayashi and Korotchenko, {K. B.} and Pivovarov, {Yu L.} and Tukhfatullin, {T. A.}",
year = "2013",
month = "11",
day = "15",
doi = "10.1016/j.nimb.2013.02.024",
language = "English",
volume = "315",
pages = "105--109",
journal = "Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms",
issn = "0168-583X",
publisher = "Elsevier",

}

TY - JOUR

T1 - Channeling and parametric X-ray studies at the SAGA Light Source

AU - Takabayashi, Y.

AU - Korotchenko, K. B.

AU - Pivovarov, Yu L.

AU - Tukhfatullin, T. A.

PY - 2013/11/15

Y1 - 2013/11/15

N2 - We present experimental results on channeling and parametric X-ray radiation obtained using a 255-MeV electron beam from an injector linac at the SAGA Light Source. Using a screen monitor, we observed both channeling phenomena and doughnut scattering by measuring the profile of an electron beam transmitted through a 20-μm-thick Si crystal. We also measured the angular distribution of parametric X-ray radiation using an imaging plate as a two-dimensional X-ray detector. The obtained results are in good agreement with theory. The final goal of these studies is the first observation of diffracted channeling radiation, and our strategy for achieving this is discussed.

AB - We present experimental results on channeling and parametric X-ray radiation obtained using a 255-MeV electron beam from an injector linac at the SAGA Light Source. Using a screen monitor, we observed both channeling phenomena and doughnut scattering by measuring the profile of an electron beam transmitted through a 20-μm-thick Si crystal. We also measured the angular distribution of parametric X-ray radiation using an imaging plate as a two-dimensional X-ray detector. The obtained results are in good agreement with theory. The final goal of these studies is the first observation of diffracted channeling radiation, and our strategy for achieving this is discussed.

KW - Channeling

KW - Diffracted channeling radiation

KW - Parametric x-ray radiation

UR - http://www.scopus.com/inward/record.url?scp=84901436256&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84901436256&partnerID=8YFLogxK

U2 - 10.1016/j.nimb.2013.02.024

DO - 10.1016/j.nimb.2013.02.024

M3 - Article

AN - SCOPUS:84901436256

VL - 315

SP - 105

EP - 109

JO - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

JF - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

SN - 0168-583X

ER -