Calculation of coaxial shunts superheat temperature

E. V. Bedareva, P. S. Marinushkin, L. I. Khudonogova

Результат исследования: Материалы для журналаСтатья

1 Цитирования (Scopus)

Аннотация

Coaxial shunt temperature field distribution has been obtained and analyzed using software package ANSYS. The main stages of 3D modeling of coaxial shunt temperature field in ANSYS are considered in the paper. It is determined that coaxial shunt temperature field distribution is nonuniform because of the material physical properties and free convection. The difference between theoretical temperature cylinder (60 °C) and experimentally observed temperature value (49 °C) of resistive pipe is caused by the fact that free convection and heat emission were not taken into account when calculating.

Язык оригиналаАнглийский
Артикульный номер012005
ЖурналIOP Conference Series: Materials Science and Engineering
Том66
Номер выпуска1
DOI
Статус публикацииОпубликовано - 2014

    Fingerprint

ASJC Scopus subject areas

  • Engineering(all)
  • Materials Science(all)

Цитировать