Biocompatible coatings on titanium implants

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

1 цитирование (Scopus)

Выдержка

Titanium metal and alloys are widely used as materials implanted. Due to the natural film of titanium oxide on titanium surface it stands against corrosion and is considered to be bioinert material. Cohesive resistance of this film as well as its strength is not high. Titanium and alloys are put on oxidation for the purpose to obtain the film with appropriate durability and dielectric properties. When implanting the titanium implants covered by film they can't be tightly bonded to the living bone because of mechanical adhesion. Electrochemical process of oxidizing results in the layer of titanium oxide ranged from 5 to 50 μm and provides the possibility of a film properties controlling. The study shows that the covering of the implant with another layer calcium and phosphorus containing provides the surface with bioactivity property as well as bioinductivity. Bioactive properties and also durability as well as thickness of the coating are controlled by the parameters of the electrochemical process. Combination and concentration of the solutions and following treatment ways make also for bioactive properties.

Язык оригиналаАнглийский
Название основной публикацииProceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology
ИздательInstitute of Electrical and Electronics Engineers Inc.
Страницы197-201
Число страниц5
Том1
ISBN (печатное издание)8978686176, 9788978686174
СостояниеОпубликовано - 2003
Событие7th Korea-Russia International Symposium on Science and Technology, KORUS 2003 - Ulsan, Республика Корея
Продолжительность: 28 июн 20036 июл 2003

Другое

Другое7th Korea-Russia International Symposium on Science and Technology, KORUS 2003
СтранаРеспублика Корея
ГородUlsan
Период28.6.036.7.03

Отпечаток

Titanium
Coatings
Titanium oxides
Durability
Corrosion
Phosphorus
Bioactivity
Titanium alloys
Metals
Dielectric properties
Calcium
Bone
Bone and Bones
Adhesion
Oxidation
titanium dioxide

ASJC Scopus subject areas

  • Building and Construction
  • Pollution
  • Biotechnology
  • Social Sciences (miscellaneous)
  • Medicine (miscellaneous)
  • Education

Цитировать

Ignatov, V. P., & Petrovskaya, T. S. (2003). Biocompatible coatings on titanium implants. В Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology (Том 1, стр. 197-201). [1222436] Institute of Electrical and Electronics Engineers Inc..

Biocompatible coatings on titanium implants. / Ignatov, Victor Pavlovich; Petrovskaya, T. S.

Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology. Том 1 Institute of Electrical and Electronics Engineers Inc., 2003. стр. 197-201 1222436.

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

Ignatov, VP & Petrovskaya, TS 2003, Biocompatible coatings on titanium implants. в Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology. том. 1, 1222436, Institute of Electrical and Electronics Engineers Inc., стр. 197-201, Ulsan, Республика Корея, 28.6.03.
Ignatov VP, Petrovskaya TS. Biocompatible coatings on titanium implants. В Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology. Том 1. Institute of Electrical and Electronics Engineers Inc. 2003. стр. 197-201. 1222436
Ignatov, Victor Pavlovich ; Petrovskaya, T. S. / Biocompatible coatings on titanium implants. Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology. Том 1 Institute of Electrical and Electronics Engineers Inc., 2003. стр. 197-201
@inproceedings{09edce01a56441a98d804e0bdc792cea,
title = "Biocompatible coatings on titanium implants",
abstract = "Titanium metal and alloys are widely used as materials implanted. Due to the natural film of titanium oxide on titanium surface it stands against corrosion and is considered to be bioinert material. Cohesive resistance of this film as well as its strength is not high. Titanium and alloys are put on oxidation for the purpose to obtain the film with appropriate durability and dielectric properties. When implanting the titanium implants covered by film they can't be tightly bonded to the living bone because of mechanical adhesion. Electrochemical process of oxidizing results in the layer of titanium oxide ranged from 5 to 50 μm and provides the possibility of a film properties controlling. The study shows that the covering of the implant with another layer calcium and phosphorus containing provides the surface with bioactivity property as well as bioinductivity. Bioactive properties and also durability as well as thickness of the coating are controlled by the parameters of the electrochemical process. Combination and concentration of the solutions and following treatment ways make also for bioactive properties.",
keywords = "Biological materials, Coatings, Corrosion, Dielectric materials, Electrochemical processes, Immune system, Implants, Inorganic materials, Surface resistance, Titanium alloys",
author = "Ignatov, {Victor Pavlovich} and Petrovskaya, {T. S.}",
year = "2003",
language = "English",
isbn = "8978686176",
volume = "1",
pages = "197--201",
booktitle = "Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Biocompatible coatings on titanium implants

AU - Ignatov, Victor Pavlovich

AU - Petrovskaya, T. S.

PY - 2003

Y1 - 2003

N2 - Titanium metal and alloys are widely used as materials implanted. Due to the natural film of titanium oxide on titanium surface it stands against corrosion and is considered to be bioinert material. Cohesive resistance of this film as well as its strength is not high. Titanium and alloys are put on oxidation for the purpose to obtain the film with appropriate durability and dielectric properties. When implanting the titanium implants covered by film they can't be tightly bonded to the living bone because of mechanical adhesion. Electrochemical process of oxidizing results in the layer of titanium oxide ranged from 5 to 50 μm and provides the possibility of a film properties controlling. The study shows that the covering of the implant with another layer calcium and phosphorus containing provides the surface with bioactivity property as well as bioinductivity. Bioactive properties and also durability as well as thickness of the coating are controlled by the parameters of the electrochemical process. Combination and concentration of the solutions and following treatment ways make also for bioactive properties.

AB - Titanium metal and alloys are widely used as materials implanted. Due to the natural film of titanium oxide on titanium surface it stands against corrosion and is considered to be bioinert material. Cohesive resistance of this film as well as its strength is not high. Titanium and alloys are put on oxidation for the purpose to obtain the film with appropriate durability and dielectric properties. When implanting the titanium implants covered by film they can't be tightly bonded to the living bone because of mechanical adhesion. Electrochemical process of oxidizing results in the layer of titanium oxide ranged from 5 to 50 μm and provides the possibility of a film properties controlling. The study shows that the covering of the implant with another layer calcium and phosphorus containing provides the surface with bioactivity property as well as bioinductivity. Bioactive properties and also durability as well as thickness of the coating are controlled by the parameters of the electrochemical process. Combination and concentration of the solutions and following treatment ways make also for bioactive properties.

KW - Biological materials

KW - Coatings

KW - Corrosion

KW - Dielectric materials

KW - Electrochemical processes

KW - Immune system

KW - Implants

KW - Inorganic materials

KW - Surface resistance

KW - Titanium alloys

UR - http://www.scopus.com/inward/record.url?scp=29144449707&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=29144449707&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:29144449707

SN - 8978686176

SN - 9788978686174

VL - 1

SP - 197

EP - 201

BT - Proceedings - KORUS 2003: 7th Korea-Russia International Symposium on Science and Technology

PB - Institute of Electrical and Electronics Engineers Inc.

ER -