Angular distribution of coherent transition radiation from 6 MeV electron beam

V. A. Cha, B. N. Kalinin, E. A. Monastyrev, G. A. Naumenko, A. P. Potylitsyn, G. A. Saruev, L. G. Sukhikh

Результат исследований: Материалы для книги/типы отчетовМатериалы для конференции

4 Цитирования (Scopus)

Аннотация

Measurements of angular distribution of coherent transition radiation (CTR) from electron bunches with energy 6.1 MeV and length σz = 1.3 mm were carried out using the detector based on broadband antenna and high-frequency diode with resulting sensitivity 0.3 V/mW at a room temperature. Parabolic mirror use for CTR focusing rejects a pre-wave zone effect. The absolute value of the CTR power agrees with theoretical prediction within experimental accuracy level.

Язык оригиналаАнглийский
Название основной публикацииProceedings of SPIE - The International Society for Optical Engineering
Том6634
DOI
СостояниеОпубликовано - 2007
СобытиеInternational Conference on Charged and Neutral Particles Channeling: Phenomena II - Rome, Италия
Продолжительность: 3 июл 20067 июл 2006

Другое

ДругоеInternational Conference on Charged and Neutral Particles Channeling: Phenomena II
СтранаИталия
ГородRome
Период3.7.067.7.06

    Fingerprint

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Condensed Matter Physics

Цитировать

Cha, V. A., Kalinin, B. N., Monastyrev, E. A., Naumenko, G. A., Potylitsyn, A. P., Saruev, G. A., & Sukhikh, L. G. (2007). Angular distribution of coherent transition radiation from 6 MeV electron beam. В Proceedings of SPIE - The International Society for Optical Engineering (Том 6634). [663416] https://doi.org/10.1117/12.741935