ANALOG CIRCUIT FOR AUTOMATIC SETTING OF THE SCALE FACTOR FOR A DIRECT-CURRENT POLAROGRAPH.

Yu A. Bulatov, Yu A. Ivanov, L. D. Svintsova, S. S. Shumilin

Результат исследований: Материалы для журналаСтатья

Выдержка

This paper considers an analog circuit providing automatic setting of the scale coefficient from the zero value of the difference current. The main difficulty arising in implementing such a circuit is associated with the controlled dc divider, which determines the metrological parameters of the entire circuit. In the proposed circuit for setting the scale factor automatically in a constant-current difference polarograph, a 525 PS2 analog multiplier was employed.

Язык оригиналаАнглийский
Страницы (с-по)1-4
Число страниц4
ЖурналIndustrial Laboratory
Том52
Номер выпуска1
СостояниеОпубликовано - янв 1986

Отпечаток

Polarographs
Analog circuits
Networks (circuits)

ASJC Scopus subject areas

  • Engineering(all)

Цитировать

Bulatov, Y. A., Ivanov, Y. A., Svintsova, L. D., & Shumilin, S. S. (1986). ANALOG CIRCUIT FOR AUTOMATIC SETTING OF THE SCALE FACTOR FOR A DIRECT-CURRENT POLAROGRAPH. Industrial Laboratory, 52(1), 1-4.

ANALOG CIRCUIT FOR AUTOMATIC SETTING OF THE SCALE FACTOR FOR A DIRECT-CURRENT POLAROGRAPH. / Bulatov, Yu A.; Ivanov, Yu A.; Svintsova, L. D.; Shumilin, S. S.

В: Industrial Laboratory, Том 52, № 1, 01.1986, стр. 1-4.

Результат исследований: Материалы для журналаСтатья

Bulatov, YA, Ivanov, YA, Svintsova, LD & Shumilin, SS 1986, 'ANALOG CIRCUIT FOR AUTOMATIC SETTING OF THE SCALE FACTOR FOR A DIRECT-CURRENT POLAROGRAPH.', Industrial Laboratory, том. 52, № 1, стр. 1-4.
Bulatov YA, Ivanov YA, Svintsova LD, Shumilin SS. ANALOG CIRCUIT FOR AUTOMATIC SETTING OF THE SCALE FACTOR FOR A DIRECT-CURRENT POLAROGRAPH. Industrial Laboratory. 1986 Янв.;52(1):1-4.
Bulatov, Yu A. ; Ivanov, Yu A. ; Svintsova, L. D. ; Shumilin, S. S. / ANALOG CIRCUIT FOR AUTOMATIC SETTING OF THE SCALE FACTOR FOR A DIRECT-CURRENT POLAROGRAPH. В: Industrial Laboratory. 1986 ; Том 52, № 1. стр. 1-4.
@article{98115d9b1792472e80ee125a17240a37,
title = "ANALOG CIRCUIT FOR AUTOMATIC SETTING OF THE SCALE FACTOR FOR A DIRECT-CURRENT POLAROGRAPH.",
abstract = "This paper considers an analog circuit providing automatic setting of the scale coefficient from the zero value of the difference current. The main difficulty arising in implementing such a circuit is associated with the controlled dc divider, which determines the metrological parameters of the entire circuit. In the proposed circuit for setting the scale factor automatically in a constant-current difference polarograph, a 525 PS2 analog multiplier was employed.",
author = "Bulatov, {Yu A.} and Ivanov, {Yu A.} and Svintsova, {L. D.} and Shumilin, {S. S.}",
year = "1986",
month = "1",
language = "English",
volume = "52",
pages = "1--4",
journal = "Journal of Parenteral and Enteral Nutrition",
issn = "0148-6071",
publisher = "Cambridge International Science Publishing",
number = "1",

}

TY - JOUR

T1 - ANALOG CIRCUIT FOR AUTOMATIC SETTING OF THE SCALE FACTOR FOR A DIRECT-CURRENT POLAROGRAPH.

AU - Bulatov, Yu A.

AU - Ivanov, Yu A.

AU - Svintsova, L. D.

AU - Shumilin, S. S.

PY - 1986/1

Y1 - 1986/1

N2 - This paper considers an analog circuit providing automatic setting of the scale coefficient from the zero value of the difference current. The main difficulty arising in implementing such a circuit is associated with the controlled dc divider, which determines the metrological parameters of the entire circuit. In the proposed circuit for setting the scale factor automatically in a constant-current difference polarograph, a 525 PS2 analog multiplier was employed.

AB - This paper considers an analog circuit providing automatic setting of the scale coefficient from the zero value of the difference current. The main difficulty arising in implementing such a circuit is associated with the controlled dc divider, which determines the metrological parameters of the entire circuit. In the proposed circuit for setting the scale factor automatically in a constant-current difference polarograph, a 525 PS2 analog multiplier was employed.

UR - http://www.scopus.com/inward/record.url?scp=0022581567&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022581567&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0022581567

VL - 52

SP - 1

EP - 4

JO - Journal of Parenteral and Enteral Nutrition

JF - Journal of Parenteral and Enteral Nutrition

SN - 0148-6071

IS - 1

ER -