A method for estimating the convective radon transport velocity in soils

Результат исследований: Материалы для журналаСтатья

7 Цитирования (Scopus)

Выдержка

A method for estimating the convective radon transport velocity in soils is developed. The approach under review is based on measurements of the radon concentration in soil air. Mathematical models for describing the convective radon transport velocity are discussed. Data on the convective radon transport velocity in commonly encountered soil types are presented. The results obtained from a 2-month experiment aimed at investigating the effect of the atmospheric condition on the convective radon transport velocity are reported. The soil gas radon concentration at 30-70 cm depth was measured by means of passive track detectors (Type III-b SSNTDs) with 72-96 h exposure time.

Язык оригиналаАнглийский
Страницы (с-по)389-391
Число страниц3
ЖурналRadiation Measurements
Том36
Номер выпуска1-6 SPEC.
DOI
СостояниеОпубликовано - 1 июн 2003

Отпечаток

Radon
radon
soils
estimating
Soils
meteorology
mathematical models
Mathematical models
Detectors
air
detectors
Air
Gases
gases
Experiments

ASJC Scopus subject areas

  • Radiation

Цитировать

A method for estimating the convective radon transport velocity in soils. / Yakovleva, Valentina Stanislavovna; Ryzhakova, N. K.

В: Radiation Measurements, Том 36, № 1-6 SPEC., 01.06.2003, стр. 389-391.

Результат исследований: Материалы для журналаСтатья

@article{5b0ede0f8d37458296b303ab094b74f2,
title = "A method for estimating the convective radon transport velocity in soils",
abstract = "A method for estimating the convective radon transport velocity in soils is developed. The approach under review is based on measurements of the radon concentration in soil air. Mathematical models for describing the convective radon transport velocity are discussed. Data on the convective radon transport velocity in commonly encountered soil types are presented. The results obtained from a 2-month experiment aimed at investigating the effect of the atmospheric condition on the convective radon transport velocity are reported. The soil gas radon concentration at 30-70 cm depth was measured by means of passive track detectors (Type III-b SSNTDs) with 72-96 h exposure time.",
keywords = "Convective radon transport, Convective velocity, Radon, Soil",
author = "Yakovleva, {Valentina Stanislavovna} and Ryzhakova, {N. K.}",
year = "2003",
month = "6",
day = "1",
doi = "10.1016/S1350-4487(03)00157-4",
language = "English",
volume = "36",
pages = "389--391",
journal = "Radiation Measurements",
issn = "1350-4487",
publisher = "Elsevier Limited",
number = "1-6 SPEC.",

}

TY - JOUR

T1 - A method for estimating the convective radon transport velocity in soils

AU - Yakovleva, Valentina Stanislavovna

AU - Ryzhakova, N. K.

PY - 2003/6/1

Y1 - 2003/6/1

N2 - A method for estimating the convective radon transport velocity in soils is developed. The approach under review is based on measurements of the radon concentration in soil air. Mathematical models for describing the convective radon transport velocity are discussed. Data on the convective radon transport velocity in commonly encountered soil types are presented. The results obtained from a 2-month experiment aimed at investigating the effect of the atmospheric condition on the convective radon transport velocity are reported. The soil gas radon concentration at 30-70 cm depth was measured by means of passive track detectors (Type III-b SSNTDs) with 72-96 h exposure time.

AB - A method for estimating the convective radon transport velocity in soils is developed. The approach under review is based on measurements of the radon concentration in soil air. Mathematical models for describing the convective radon transport velocity are discussed. Data on the convective radon transport velocity in commonly encountered soil types are presented. The results obtained from a 2-month experiment aimed at investigating the effect of the atmospheric condition on the convective radon transport velocity are reported. The soil gas radon concentration at 30-70 cm depth was measured by means of passive track detectors (Type III-b SSNTDs) with 72-96 h exposure time.

KW - Convective radon transport

KW - Convective velocity

KW - Radon

KW - Soil

UR - http://www.scopus.com/inward/record.url?scp=0042363720&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0042363720&partnerID=8YFLogxK

U2 - 10.1016/S1350-4487(03)00157-4

DO - 10.1016/S1350-4487(03)00157-4

M3 - Article

AN - SCOPUS:0042363720

VL - 36

SP - 389

EP - 391

JO - Radiation Measurements

JF - Radiation Measurements

SN - 1350-4487

IS - 1-6 SPEC.

ER -