XeCl-, KrCl-, XeBr- and KrBr-excilamps of the barrier discharge with the nanosecond pulse duration of radiation

M. V. Erofeev, V. F. Tarasenko

Research output: Contribution to journalArticle

36 Citations (Scopus)

Abstract

Results of researches on coaxial one- and two-barrier excilamps based on molecules XeCl* (λ ∼ 308 nm), KrCl* (λ ∼ 222 nm), XeBr* (λ ∼ 282 nm) and KrBr* (λ ∼ 206 nm) with a short-pulse duration of radiation are given. The peak power of radiation ∼500 W cm-2 and 4 ns full width at half-maximum (FWHM) are obtained on excitation of a working mixture by the high-voltage pulse generator 'Radan-150' with a nanosecond duration in mixtures with a ratio of rare gas/halogen ≤ 50/1 and total pressure of 500 Torr. The peak power of radiation of the one-barrier KrCl-excilamp excited by the combined Fitch circuit is 1.1 kW cm-2 at 107 ns FWHM.

Original languageEnglish
Article number013
Pages (from-to)3609-3614
Number of pages6
JournalJournal of Physics D: Applied Physics
Volume39
Issue number16
DOIs
Publication statusPublished - 21 Aug 2006

Fingerprint

pulse duration
Full width at half maximum
Radiation
radiation
Noble Gases
Halogens
Pulse generators
pulse generators
Inert gases
halogens
high voltages
rare gases
Molecules
Networks (circuits)
Electric potential
excitation
molecules

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)

Cite this

XeCl-, KrCl-, XeBr- and KrBr-excilamps of the barrier discharge with the nanosecond pulse duration of radiation. / Erofeev, M. V.; Tarasenko, V. F.

In: Journal of Physics D: Applied Physics, Vol. 39, No. 16, 013, 21.08.2006, p. 3609-3614.

Research output: Contribution to journalArticle

@article{be0f489f59de4a019335b9ead59009eb,
title = "XeCl-, KrCl-, XeBr- and KrBr-excilamps of the barrier discharge with the nanosecond pulse duration of radiation",
abstract = "Results of researches on coaxial one- and two-barrier excilamps based on molecules XeCl* (λ ∼ 308 nm), KrCl* (λ ∼ 222 nm), XeBr* (λ ∼ 282 nm) and KrBr* (λ ∼ 206 nm) with a short-pulse duration of radiation are given. The peak power of radiation ∼500 W cm-2 and 4 ns full width at half-maximum (FWHM) are obtained on excitation of a working mixture by the high-voltage pulse generator 'Radan-150' with a nanosecond duration in mixtures with a ratio of rare gas/halogen ≤ 50/1 and total pressure of 500 Torr. The peak power of radiation of the one-barrier KrCl-excilamp excited by the combined Fitch circuit is 1.1 kW cm-2 at 107 ns FWHM.",
author = "Erofeev, {M. V.} and Tarasenko, {V. F.}",
year = "2006",
month = "8",
day = "21",
doi = "10.1088/0022-3727/39/16/013",
language = "English",
volume = "39",
pages = "3609--3614",
journal = "Journal Physics D: Applied Physics",
issn = "0022-3727",
publisher = "IOP Publishing Ltd.",
number = "16",

}

TY - JOUR

T1 - XeCl-, KrCl-, XeBr- and KrBr-excilamps of the barrier discharge with the nanosecond pulse duration of radiation

AU - Erofeev, M. V.

AU - Tarasenko, V. F.

PY - 2006/8/21

Y1 - 2006/8/21

N2 - Results of researches on coaxial one- and two-barrier excilamps based on molecules XeCl* (λ ∼ 308 nm), KrCl* (λ ∼ 222 nm), XeBr* (λ ∼ 282 nm) and KrBr* (λ ∼ 206 nm) with a short-pulse duration of radiation are given. The peak power of radiation ∼500 W cm-2 and 4 ns full width at half-maximum (FWHM) are obtained on excitation of a working mixture by the high-voltage pulse generator 'Radan-150' with a nanosecond duration in mixtures with a ratio of rare gas/halogen ≤ 50/1 and total pressure of 500 Torr. The peak power of radiation of the one-barrier KrCl-excilamp excited by the combined Fitch circuit is 1.1 kW cm-2 at 107 ns FWHM.

AB - Results of researches on coaxial one- and two-barrier excilamps based on molecules XeCl* (λ ∼ 308 nm), KrCl* (λ ∼ 222 nm), XeBr* (λ ∼ 282 nm) and KrBr* (λ ∼ 206 nm) with a short-pulse duration of radiation are given. The peak power of radiation ∼500 W cm-2 and 4 ns full width at half-maximum (FWHM) are obtained on excitation of a working mixture by the high-voltage pulse generator 'Radan-150' with a nanosecond duration in mixtures with a ratio of rare gas/halogen ≤ 50/1 and total pressure of 500 Torr. The peak power of radiation of the one-barrier KrCl-excilamp excited by the combined Fitch circuit is 1.1 kW cm-2 at 107 ns FWHM.

UR - http://www.scopus.com/inward/record.url?scp=33746930661&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33746930661&partnerID=8YFLogxK

U2 - 10.1088/0022-3727/39/16/013

DO - 10.1088/0022-3727/39/16/013

M3 - Article

VL - 39

SP - 3609

EP - 3614

JO - Journal Physics D: Applied Physics

JF - Journal Physics D: Applied Physics

SN - 0022-3727

IS - 16

M1 - 013

ER -