Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě

Translated title of the contribution: Voltammetric determination of submicromolar concentrations of 3-nitrofluoranthene and pendimethalin at silver solid amalgam electrode

Lucie Vaňková, Lucie Maixnerová, Karel Čížek, Jan Fischer, Jiří Barek, Tomáš Navrátil, Bogdan Yosypchuk

Research output: Contribution to journalArticle

37 Citations (Scopus)

Abstract

Optimum conditions are described for the determination of genotoxic 3-nitrofluoranthene (3-NF) and pendimethalin using differential pulse voltammetry (DPV). The limits of quantification (LQ) around 4·10-7 mol 1-1 were found for both 3-NF and pendimethalin. In addition, adsorptive stripping voltammetry was applied for determination of 3-NF with LQ around 3·10-8 mol 1-1. The practical applicability of newly developed methods was demonstrated on direct determination of pendimethalin in model samples of drinking water by DPV with LQ around 5·10-7 mol 1-1.

Original languageCzech
Pages (from-to)1105-1110
Number of pages6
JournalChemicke Listy
Volume100
Issue number12
Publication statusPublished - 1 Dec 2006
Externally publishedYes

Fingerprint

Mercury amalgams
Voltammetry
Silver
Electrodes
Drinking Water
pendimethalin
3-nitrofluoranthene

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

Vaňková, L., Maixnerová, L., Čížek, K., Fischer, J., Barek, J., Navrátil, T., & Yosypchuk, B. (2006). Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě. Chemicke Listy, 100(12), 1105-1110.

Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě. / Vaňková, Lucie; Maixnerová, Lucie; Čížek, Karel; Fischer, Jan; Barek, Jiří; Navrátil, Tomáš; Yosypchuk, Bogdan.

In: Chemicke Listy, Vol. 100, No. 12, 01.12.2006, p. 1105-1110.

Research output: Contribution to journalArticle

Vaňková, L, Maixnerová, L, Čížek, K, Fischer, J, Barek, J, Navrátil, T & Yosypchuk, B 2006, 'Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě', Chemicke Listy, vol. 100, no. 12, pp. 1105-1110.
Vaňková, Lucie ; Maixnerová, Lucie ; Čížek, Karel ; Fischer, Jan ; Barek, Jiří ; Navrátil, Tomáš ; Yosypchuk, Bogdan. / Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě. In: Chemicke Listy. 2006 ; Vol. 100, No. 12. pp. 1105-1110.
@article{14f091739fc6410aa9f2efc181404437,
title = "Voltametrick{\'e} stanoven{\'i} submikromol{\'a}rn{\'i}ch koncentrac{\'i} 3-nitrofluoranthenu a pendimethalinu NA stř{\'i} brn{\'e} pevn{\'e} amalg{\'a}mov{\'e} elektrodě",
abstract = "Optimum conditions are described for the determination of genotoxic 3-nitrofluoranthene (3-NF) and pendimethalin using differential pulse voltammetry (DPV). The limits of quantification (LQ) around 4·10-7 mol 1-1 were found for both 3-NF and pendimethalin. In addition, adsorptive stripping voltammetry was applied for determination of 3-NF with LQ around 3·10-8 mol 1-1. The practical applicability of newly developed methods was demonstrated on direct determination of pendimethalin in model samples of drinking water by DPV with LQ around 5·10-7 mol 1-1.",
author = "Lucie Vaňkov{\'a} and Lucie Maixnerov{\'a} and Karel Č{\'i}žek and Jan Fischer and Jiř{\'i} Barek and Tom{\'a}š Navr{\'a}til and Bogdan Yosypchuk",
year = "2006",
month = "12",
day = "1",
language = "Czech",
volume = "100",
pages = "1105--1110",
journal = "Chemicke Listy",
issn = "0009-2770",
publisher = "Czech Society of Chemical Engineering",
number = "12",

}

TY - JOUR

T1 - Voltametrické stanovení submikromolárních koncentrací 3-nitrofluoranthenu a pendimethalinu NA stří brné pevné amalgámové elektrodě

AU - Vaňková, Lucie

AU - Maixnerová, Lucie

AU - Čížek, Karel

AU - Fischer, Jan

AU - Barek, Jiří

AU - Navrátil, Tomáš

AU - Yosypchuk, Bogdan

PY - 2006/12/1

Y1 - 2006/12/1

N2 - Optimum conditions are described for the determination of genotoxic 3-nitrofluoranthene (3-NF) and pendimethalin using differential pulse voltammetry (DPV). The limits of quantification (LQ) around 4·10-7 mol 1-1 were found for both 3-NF and pendimethalin. In addition, adsorptive stripping voltammetry was applied for determination of 3-NF with LQ around 3·10-8 mol 1-1. The practical applicability of newly developed methods was demonstrated on direct determination of pendimethalin in model samples of drinking water by DPV with LQ around 5·10-7 mol 1-1.

AB - Optimum conditions are described for the determination of genotoxic 3-nitrofluoranthene (3-NF) and pendimethalin using differential pulse voltammetry (DPV). The limits of quantification (LQ) around 4·10-7 mol 1-1 were found for both 3-NF and pendimethalin. In addition, adsorptive stripping voltammetry was applied for determination of 3-NF with LQ around 3·10-8 mol 1-1. The practical applicability of newly developed methods was demonstrated on direct determination of pendimethalin in model samples of drinking water by DPV with LQ around 5·10-7 mol 1-1.

UR - http://www.scopus.com/inward/record.url?scp=33845785947&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33845785947&partnerID=8YFLogxK

M3 - Статья

VL - 100

SP - 1105

EP - 1110

JO - Chemicke Listy

JF - Chemicke Listy

SN - 0009-2770

IS - 12

ER -