Voltammetric determination of homovanillic acid and vanillylmandelic acid on a disposable electrochemical measuring cell system with integrated carbon composite film electrodes

Milan Libansky, Jiri Zima, Jiri Barek, Hana Dejmkova

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

An array of carbon composite electrodes embedded in a 96-well microtitration plate was applied to differential pulse voltammetry determination of standards of tumor biomarkers 2-(4-hydroxy-3-methoxy-phenyl) acetic acid (homovanillic acid, HVA) and (RS)-hydroxy(4-hydroxy-3-methoxy-phenyl) acetic acid (vanillylmandelic acid, VMA). For the preparation of composite electrodes, graphitic conductive microparticles and nonconductive polystyrene binder were used. For the measurement, a buffer of pH 2 was selected as the optimum medium for both analytes. In this medium, concentration dependences of stand-alone standards were measured; calculated quantification limits were 0.3 μmol dm-3 for HVA and 0.8 μmol dm-3 for VMA. Sorption of analytes on employed working electrode was examined in order to verify, whether the current is influenced by the time period between cell filling and measurement. The sorption was not observed and the current was stable even after 10 min. Developed method was verified by the determination of a mixture of standards of both analytes. Mixtures of analytes of various proportions were measured and the obtained calibration curves showed good agreement with standard values. Furthermore, the results showed that the behavior of the mixture of analytes is not different from the behavior of the actual standards, so that it is possible to calculate the concentration of both analytes side by side. Graphical abstract: [Figure not available: see fulltext.]

Original languageEnglish
Pages (from-to)89-96
Number of pages8
JournalMonatshefte fur Chemie
Volume147
Issue number1
DOIs
Publication statusPublished - 1 Jan 2016

Fingerprint

Vanilmandelic Acid
Homovanillic Acid
Carbon films
Composite films
Electrodes
Acetic Acid
Sorption
Polystyrenes
Composite materials
Voltammetry
Tumor Biomarkers
Binders
Buffers
Carbon
Calibration

Keywords

  • Array of electrodes
  • Electrochemistry
  • Microtitration plate
  • Oxidations
  • Tumor biomarkers
  • Voltammetry

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

Voltammetric determination of homovanillic acid and vanillylmandelic acid on a disposable electrochemical measuring cell system with integrated carbon composite film electrodes. / Libansky, Milan; Zima, Jiri; Barek, Jiri; Dejmkova, Hana.

In: Monatshefte fur Chemie, Vol. 147, No. 1, 01.01.2016, p. 89-96.

Research output: Contribution to journalArticle

@article{9db54cc95e7c4f2cade55c8968c0638e,
title = "Voltammetric determination of homovanillic acid and vanillylmandelic acid on a disposable electrochemical measuring cell system with integrated carbon composite film electrodes",
abstract = "An array of carbon composite electrodes embedded in a 96-well microtitration plate was applied to differential pulse voltammetry determination of standards of tumor biomarkers 2-(4-hydroxy-3-methoxy-phenyl) acetic acid (homovanillic acid, HVA) and (RS)-hydroxy(4-hydroxy-3-methoxy-phenyl) acetic acid (vanillylmandelic acid, VMA). For the preparation of composite electrodes, graphitic conductive microparticles and nonconductive polystyrene binder were used. For the measurement, a buffer of pH 2 was selected as the optimum medium for both analytes. In this medium, concentration dependences of stand-alone standards were measured; calculated quantification limits were 0.3 μmol dm-3 for HVA and 0.8 μmol dm-3 for VMA. Sorption of analytes on employed working electrode was examined in order to verify, whether the current is influenced by the time period between cell filling and measurement. The sorption was not observed and the current was stable even after 10 min. Developed method was verified by the determination of a mixture of standards of both analytes. Mixtures of analytes of various proportions were measured and the obtained calibration curves showed good agreement with standard values. Furthermore, the results showed that the behavior of the mixture of analytes is not different from the behavior of the actual standards, so that it is possible to calculate the concentration of both analytes side by side. Graphical abstract: [Figure not available: see fulltext.]",
keywords = "Array of electrodes, Electrochemistry, Microtitration plate, Oxidations, Tumor biomarkers, Voltammetry",
author = "Milan Libansky and Jiri Zima and Jiri Barek and Hana Dejmkova",
year = "2016",
month = "1",
day = "1",
doi = "10.1007/s00706-015-1583-8",
language = "English",
volume = "147",
pages = "89--96",
journal = "Monatshefte fur Chemie",
issn = "0026-9247",
publisher = "Springer Wien",
number = "1",

}

TY - JOUR

T1 - Voltammetric determination of homovanillic acid and vanillylmandelic acid on a disposable electrochemical measuring cell system with integrated carbon composite film electrodes

AU - Libansky, Milan

AU - Zima, Jiri

AU - Barek, Jiri

AU - Dejmkova, Hana

PY - 2016/1/1

Y1 - 2016/1/1

N2 - An array of carbon composite electrodes embedded in a 96-well microtitration plate was applied to differential pulse voltammetry determination of standards of tumor biomarkers 2-(4-hydroxy-3-methoxy-phenyl) acetic acid (homovanillic acid, HVA) and (RS)-hydroxy(4-hydroxy-3-methoxy-phenyl) acetic acid (vanillylmandelic acid, VMA). For the preparation of composite electrodes, graphitic conductive microparticles and nonconductive polystyrene binder were used. For the measurement, a buffer of pH 2 was selected as the optimum medium for both analytes. In this medium, concentration dependences of stand-alone standards were measured; calculated quantification limits were 0.3 μmol dm-3 for HVA and 0.8 μmol dm-3 for VMA. Sorption of analytes on employed working electrode was examined in order to verify, whether the current is influenced by the time period between cell filling and measurement. The sorption was not observed and the current was stable even after 10 min. Developed method was verified by the determination of a mixture of standards of both analytes. Mixtures of analytes of various proportions were measured and the obtained calibration curves showed good agreement with standard values. Furthermore, the results showed that the behavior of the mixture of analytes is not different from the behavior of the actual standards, so that it is possible to calculate the concentration of both analytes side by side. Graphical abstract: [Figure not available: see fulltext.]

AB - An array of carbon composite electrodes embedded in a 96-well microtitration plate was applied to differential pulse voltammetry determination of standards of tumor biomarkers 2-(4-hydroxy-3-methoxy-phenyl) acetic acid (homovanillic acid, HVA) and (RS)-hydroxy(4-hydroxy-3-methoxy-phenyl) acetic acid (vanillylmandelic acid, VMA). For the preparation of composite electrodes, graphitic conductive microparticles and nonconductive polystyrene binder were used. For the measurement, a buffer of pH 2 was selected as the optimum medium for both analytes. In this medium, concentration dependences of stand-alone standards were measured; calculated quantification limits were 0.3 μmol dm-3 for HVA and 0.8 μmol dm-3 for VMA. Sorption of analytes on employed working electrode was examined in order to verify, whether the current is influenced by the time period between cell filling and measurement. The sorption was not observed and the current was stable even after 10 min. Developed method was verified by the determination of a mixture of standards of both analytes. Mixtures of analytes of various proportions were measured and the obtained calibration curves showed good agreement with standard values. Furthermore, the results showed that the behavior of the mixture of analytes is not different from the behavior of the actual standards, so that it is possible to calculate the concentration of both analytes side by side. Graphical abstract: [Figure not available: see fulltext.]

KW - Array of electrodes

KW - Electrochemistry

KW - Microtitration plate

KW - Oxidations

KW - Tumor biomarkers

KW - Voltammetry

UR - http://www.scopus.com/inward/record.url?scp=84952845243&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84952845243&partnerID=8YFLogxK

U2 - 10.1007/s00706-015-1583-8

DO - 10.1007/s00706-015-1583-8

M3 - Article

VL - 147

SP - 89

EP - 96

JO - Monatshefte fur Chemie

JF - Monatshefte fur Chemie

SN - 0026-9247

IS - 1

ER -